Measurement of dental implant stability by resonance frequency analysis: a review of the literature.

Maria-Pilar Quesada-García1, Estrella Prados-Sánchez, Maria-Victoria Olmedo-Gaya, Esther Muñoz-Soto, Maria-Paloma González-Rodríguez, Manuel Valllecillo-Capilla.   

Abstract

Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion) and secondary stability (bone formation and remodelling at implant-bone interface). The aim of this study was to review the literature on Resonance Frequency Analysis (RFA) as a method for measuring dental implant stability. An online search of various databases was conducted on experimental and clinical research published between 1996 and 2008. The studies reviewed demonstrate the usefulness of RFA as a non-invasive method to assess implant stability. Further research is required to determine whether this system is also capable of measuring the degree of dental implant osseointegration.

Mesh:

Substances:

Year:  2009        PMID: 19680211     DOI: 10.4317/medoral.14.e538

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  14 in total

1.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

2.  CO2 laser surface treatment of failed dental implants for re-implantation: an animal study.

Authors:  Shahin Kasraei; Parviz Torkzaban; Bahar Shams; Seyed Mohammad Hosseinipanah; Maryam Farhadian
Journal:  Lasers Med Sci       Date:  2016-04-28       Impact factor: 3.161

3.  [Effect of osseointegration in the posterior area by Shenggu pills].

Authors:  Luo Cuifen; Peng Guoguang
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-10-01

4.  Intra- and inter-operator concordance of the resonance frequency analysis. A cross-sectional and prospective clinical study.

Authors:  Raquel Antequera-Diaz; Maria-Pilar Quesada-García; Cristina Vallecillo; Marta Vallecillo-Rivas; Esther Muñoz-Soto; Maria-Victoria Olmedo-Gaya
Journal:  Clin Oral Investig       Date:  2022-07-08       Impact factor: 3.573

5.  Mini-implant stability at the initial healing period: a clinical pilot study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Angle Orthod       Date:  2013-07-24       Impact factor: 2.079

6.  Impact of mini-implant length on stability at the initial healing period: a controlled clinical study.

Authors:  Manuel Nienkemper; Benedict Wilmes; Alexander Pauls; Dieter Drescher
Journal:  Head Face Med       Date:  2013-10-20       Impact factor: 2.151

7.  Customized SmartPeg for measurement of resonance frequency of mini dental implants.

Authors:  Jagjit Singh Dhaliwal; Rubens F Albuquerque; Ali Fakhry; Sukhbir Kaur; Jocelyne S Feine
Journal:  Int J Implant Dent       Date:  2017-02-01

8.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

9.  Multivariate linear regression analysis to identify general factors for quantitative predictions of implant stability quotient values.

Authors:  Hairong Huang; Zanzan Xu; Xianhong Shao; Daniel Wismeijer; Ping Sun; Jingxiao Wang; Gang Wu
Journal:  PLoS One       Date:  2017-10-30       Impact factor: 3.240

10.  Bone implant sockets made using three different procedures: a stability study in dogs.

Authors:  Jorge Cano; Julián Campo
Journal:  J Clin Exp Dent       Date:  2012-10-01