Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.

Bruce J Gerbi1, John A Antolak, F Christopher Deibel, David S Followill, Michael G Herman, Patrick D Higgins, M Saiful Huq, Dimitris N Mihailidis, Ellen D Yorke, Kenneth R Hogstrom, Faiz M Khan.   

Abstract

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of.Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance testing and treatment planning of new accelerators with therapeutic electron beams. Since the publication of the TG-25 report, significant advances have taken place in the field of electron beam dosimetry, the most significant being that primary standards laboratories around the world have shifted from calibration standards based on exposure or air kerma to standards based on absorbed dose to water. The AAPM has published a new calibration protocol, TG-51, for the calibration of high-energy photon and electron beams. The formalism and dosimetry procedures recommended in this protocol are based on the absorbed dose to water calibration coefficient of an ionization chamber at 60Co energy, N60Co(D,w), together with the theoretical beam quality conversion coefficient k(Q) for the determination of absorbed dose to water in high-energy photon and electron beams. Task Group 70 was charged to reassess and update the recommendations in TG-25 to bring them into alignment with report TG-51 and to recommend new methodologies and procedures that would allow the practicing medical physicist to initiate and continue a high quality program in clinical electron beam dosimetry. This TG-70 report is a supplement to the TG-25 report and enhances the TG-25 report by including new topics and topics that were not covered in depth in the TG-25 report. These topics include procedures for obtaining data to commission a treatment planning computer, determining dose in irregularly shaped electron fields, and commissioning of sophisticated special procedures using high-energy electron beams. The use of radiochromic film for electrons is addressed, and radiographic film that is no longer available has been replaced by film that is available. Realistic stopping-power data are incorporated when appropriate along with enhanced tables of electron fluence data. A larger list of clinical applications of electron beams is included in the full TG-70 report available at http://www.aapm.org/pubs/reports. Descriptions of the techniques in the clinical sections are not exhaustive but do describe key elements of the procedures and how to initiate these programs in the clinic. There have been no major changes since the TG-25 report relating to flatness and symmetry, surface dose, use of thermoluminescent dosimeters or diodes, virtual source position designation, air gap corrections, oblique incidence, or corrections for inhomogeneities. Thus these topics are not addressed in the TG-70 report.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19673223     DOI: 10.1118/1.3125820

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  34 in total

1.  An ionizing radiation acoustic imaging (iRAI) technique for real-time dosimetric measurements for FLASH radiotherapy.

Authors:  Ibrahim Oraiqat; Wei Zhang; Dale Litzenberg; Kwok Lam; Noora Ba Sunbul; Jean Moran; Kyle Cuneo; Paul Carson; Xueding Wang; Issam El Naqa
Journal:  Med Phys       Date:  2020-08-16       Impact factor: 4.071

2.  Fractionation of high-dose electron beam irradiation of BPTB grafts provides significantly improved viscoelastic and structural properties compared to standard gamma irradiation.

Authors:  A Hoburg; S Keshlaf; T Schmidt; M Smith; U Gohs; C Perka; A Pruss; S Scheffler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-04       Impact factor: 4.342

3.  Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.

Authors:  Aiping Ding; Lei Xing; Bin Han
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

4.  Total skin electron beam therapy using an inclinable couch on motorized table and a compensating filter.

Authors:  H Fuse; K Suzuki; K Shida; Y Mori; H Takahashi; D Kobayashi; M Seki; T Isobe; T Okumura; T Sakae; H Sakurai
Journal:  Rev Sci Instrum       Date:  2014-06       Impact factor: 1.523

5.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

6.  Inactivation Effect of Standard and Fractionated Electron Beam Irradiation on Enveloped and Non-Enveloped Viruses in a Tendon Transplant Model.

Authors:  Tanja Schmidt; Arnd T Hoburg; Uwe Gohs; Wolfgang Schumann; Jung-Won Sim-Brandenburg; Andreas Nitsche; Sven Scheffler; Axel Pruss
Journal:  Transfus Med Hemother       Date:  2012-01-20       Impact factor: 3.747

7.  Implementation and experimental validation of a robust hybrid direct aperture optimization approach for mixed-beam radiotherapy.

Authors:  Emily Heath; Silvan Mueller; Gian Guyer; Alisha Duetschler; Olgun Elicin; Daniel Aebersold; Michael K Fix; Peter Manser
Journal:  Med Phys       Date:  2021-10-14       Impact factor: 4.506

8.  A preliminary safety assessment of vertebral augmentation with32P brachytherapy bone cement.

Authors:  Joyce H Keyak; Mando L Eijansantos; Katherine G Rosecrance; Daniel Wong; Sayeh Feizi; Aleen L Meldosian; Pranav Peddinti; Clifford M Les; Harry B Skinner; Varun Sehgal
Journal:  Phys Med Biol       Date:  2022-04-01       Impact factor: 4.174

9.  A comparison of symmetry and flatness measurements in small electron fields by different dosimeters in electron beam radiotherapy.

Authors:  Mohamad Reza Bayatiani; Fatemeh Fallahi; Akbar Aliasgharzadeh; Mahdi Ghorbani; Benyamin Khajetash; Fatemeh Seif
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25

10.  A systematic approach to statistical analysis in dosimetry and patient-specific IMRT plan verification measurements.

Authors:  Songbing Qin; Miao Zhang; Sung Kim; Ting Chen; Leonard H Kim; Bruce G Haffty; Ning J Yue
Journal:  Radiat Oncol       Date:  2013-09-30       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.