Literature DB >> 19656657

Selection of optimal dental implant diameter and length in type IV bone: a three-dimensional finite element analysis.

T Li1, L Kong, Y Wang, K Hu, L Song, B Liu, D Li, J Shao, Y Ding.   

Abstract

This study aimed to create a 3D finite element model for continuous variation of implant diameter and length, thereby identifying their optimal range in type IV bone under biomechanical consideration. Implant diameter ranged from 3.0 to 5.0mm, and implant length ranged from 6.0 to 14.0mm. The results suggest that under axial load, the maximum Von Mises stresses in cortical and cancellous bones decrease by 50% and 27%, respectively; and under buccolingual load, by 52% and 60%, respectively. Under these two loads, the maximum displacements of implant-abutment complex decrease by 39% and 43%, respectively. These results indicate that in type IV bone, implant length is more crucial in reducing bone stress and enhancing the stability of implant-abutment complex than implant diameter. Biomechanically, implant diameter exceeding 4.0mm and implant length exceeding 9.0mm are the combination with optimal properties for a screwed implant in type IV bone.

Mesh:

Substances:

Year:  2009        PMID: 19656657     DOI: 10.1016/j.ijom.2009.07.001

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  8 in total

1.  Stress Distribution Around Single Short Dental Implants: A Finite Element Study.

Authors:  S Vidya Bhat; Priyanka Premkumar; K Kamalakanth Shenoy
Journal:  J Indian Prosthodont Soc       Date:  2014-09-10

2.  Three-dimensional finite element analysis of platform switched implant.

Authors:  Se-Young Moon; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

3.  Bone quality effect on short implants in the edentulous mandible: a finite element study.

Authors:  Chaowei Liu; Yifeng Xing; Yan Li; Yanjun Lin; Jianghan Xu; Dong Wu
Journal:  BMC Oral Health       Date:  2022-04-26       Impact factor: 3.747

4.  Bivariate optimization of orthodontic mini-implant thread height and pitch.

Authors:  Shuning Shen; Yingying Sun; Chen Zhang; Yongjin Yang; Zhiren Li; Xingwei Cai; Yinzhong Duan; Tao Li
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-08-27       Impact factor: 2.924

5.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

6.  Numerical Method for the Design of Healing Chamber in Additive-Manufactured Dental Implants.

Authors:  Hsiao-Chien Lee; Pei-I Tsai; Chih-Chieh Huang; San-Yuan Chen; Chuen-Guang Chao; Nien-Ti Tsou
Journal:  Biomed Res Int       Date:  2017-02-12       Impact factor: 3.411

7.  Comparison of the Effect of Three Abutment-implant Connections on Stress Distribution at the Internal Surface of Dental Implants: A Finite Element Analysis.

Authors:  Saeed Raoofi; Maryam Khademi; Reza Amid; Mahdi Kadkhodazadeh; Mohammad Reza Movahhedi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-08-30

8.  Numerical study of effect of elastomeric stress absorbers on stress reduction in bone-dental implant interface.

Authors:  Ghalem Mehdi; Abderrahmane Belarbi; Bensmaine Mansouri; Zitouni Azari
Journal:  J Appl Oral Sci       Date:  2015 Jan-Feb       Impact factor: 2.698

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.