Literature DB >> 19651353

Buccal cortical bone thickness for mini-implant placement.

Sebastian Baumgaertel1, Mark G Hans.   

Abstract

INTRODUCTION: The thickness of cortical bone is an important factor in mini-implant stability. In this study, we investigated the buccal cortical bone thickness of every interdental area as an aid in planning mini-implant placement.
METHODS: From the cone-beam computed tomography scans of 30 dry skulls, 2-dimensional slices through every interdental area were generated. On these, cortical bone thickness was measured at 2, 4, and 6 mm from the alveolar crest. Intraclass correlation was used to determine intrarater reliability, and analysis of variance (ANOVA) was used to test for differences in cortical bone thickness.
RESULTS: Buccal cortical bone thickness was greater in the mandible than in the maxilla. Whereas this thickness increased with increasing distance from the alveolar crest in the mandible and in the maxillary anterior sextant, it behaved differently in the maxillary buccal sextants; it was thinnest at the 4-mm level.
CONCLUSIONS: Interdental buccal cortical bone thickness varies in the jaws. There appears to be a distinct pattern. Knowledge of this pattern and the mean values for thickness can aid in mini-implant site selection and preparation.

Entities:  

Mesh:

Year:  2009        PMID: 19651353     DOI: 10.1016/j.ajodo.2007.10.045

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  42 in total

1.  A report on the use of Er:YAG laser for pilot hole drilling prior to miniscrew insertion.

Authors:  Fulya Ozdemir; Hande Biceroglu Demir; Mehmet Oguz Oztoprak; Murat Tozlu
Journal:  Lasers Med Sci       Date:  2013-06-23       Impact factor: 3.161

2.  Comparison of interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns using cone-beam computed tomography.

Authors:  Nattida Khumsarn; Virush Patanaporn; Apirum Janhom; Dhirawat Jotikasthira
Journal:  Imaging Sci Dent       Date:  2016-06-23

3.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

4.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

5.  Alveolar bone loss around incisors in Class I bidentoalveolar protrusion patients: a retrospective three-dimensional cone beam CT study.

Authors:  K-Y Nahm; J-H Kang; S-C Moon; Y-S Choi; Y-A Kook; S-H Kim; Jc Huang
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

6.  A CBCT atlas of buccal cortical bone thickness in interradicular spaces.

Authors:  Patrick B Holmes; Bethany J Wolf; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

7.  An evaluation of insertion sites for mini-implants: a micro - CT study of human autopsy material.

Authors:  Morten G Laursen; Birte Melsen; Paolo M Cattaneo
Journal:  Angle Orthod       Date:  2012-08-27       Impact factor: 2.079

8.  Effects of predrilling depth and implant shape on the mechanical properties of orthodontic mini-implants during the insertion procedure.

Authors:  Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-11-03       Impact factor: 2.079

9.  Root proximity and cortical bone thickness effects on the success rate of orthodontic micro-implants using cone beam computed tomography.

Authors:  Kyung-Inn Min; Sang-Cheol Kim; Kyung-Hwa Kang; Jin-Hyoung Cho; Eon-Hwa Lee; Na-Young Chang; Jong-Moon Chae
Journal:  Angle Orthod       Date:  2012-03-14       Impact factor: 2.079

10.  Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure.

Authors:  Yoon-Young Heo; Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-03-03       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.