In vivo feasibility of real-time monitoring of focused ultrasound surgery (FUS) using harmonic motion imaging (HMI).

Caroline Maleke1, Elisa E Konofagou.   

Abstract

In this study, the Harmonic Motion Imaging for Focused Ultrasound (HMIFU) technique is applied to monitor changes in mechanical properties of tissues during thermal therapy in a transgenic breast cancer mouse model in vivo. An HMIFU system, composed of a 4.5-MHz focused ultrasound (FUS) and a 3.3-MHz phased-array imaging transducer, was mechanically moved to image and ablate the entire tumor. The FUS transducer was driven by an amplitude-modulated (AM) signal at 15 Hz. The acoustic intensity ( I(spta)) was equal to 1050 W/cm(2) at the focus. A digital low-pass filter was used to filter out the spectrum of the FUS beam and its harmonics prior to displacement estimation. The resulting axial displacement was estimated using 1-D cross-correlation on the acquired RF signals. Results from two mice with eight lesions formed in each mouse (16 lesions total) showed that the average peak-to-peak displacement amplitude before and after lesion formation was respectively equal to 17.34 +/- 1.34 microm and 10.98 +/- 1.82 microm ( p << 0.001). Cell death was also confirmed by hematoxylin and eosin histology. HMI displacement can be used to monitor the relative tissue stiffness changes in real time during heating so that the treatment procedure can be performed in a time-efficient manner. The HMIFU system may, therefore, constitute a cost-efficient and reliable alternative for real-time monitoring of thermal ablation.

Entities:  

Mesh:

Year:  2009        PMID: 19643703     DOI: 10.1109/TBME.2009.2027423

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  24 in total

1.  Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Authors:  Elisa E Konofagou; Caroline Maleke; Jonathan Vappou
Journal:  Curr Med Imaging Rev       Date:  2012

2.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

3.  Phase-shift perfluorocarbon agents enhance high intensity focused ultrasound thermal delivery with reduced near-field heating.

Authors:  Linsey C Phillips; Connor Puett; Paul S Sheeran; G Wilson Miller; Terry O Matsunaga; Paul A Dayton
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

Review 4.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

5.  Analysis of tissue changes, measurement system effects, and motion artifacts in echo decorrelation imaging.

Authors:  Fong Ming Hooi; Anna Nagle; Swetha Subramanian; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2015-02       Impact factor: 1.840

6.  High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).

Authors:  Yang Han; Gary Yi Hou; Shutao Wang; Elisa Konofagou
Journal:  Phys Med Biol       Date:  2015-07-17       Impact factor: 3.609

Review 7.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

8.  Performance assessment of HIFU lesion detection by harmonic motion imaging for focused ultrasound (HMIFU): a 3-D finite-element-based framework with experimental validation.

Authors:  Gary Y Hou; Jianwen Luo; Fabrice Marquet; Caroline Maleke; Jonathan Vappou; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2011-10-27       Impact factor: 2.998

9.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

10.  Sparse matrix beamforming and image reconstruction for 2-D HIFU monitoring using harmonic motion imaging for focused ultrasound (HMIFU) with in vitro validation.

Authors:  Gary Y Hou; Jean Provost; Julien Grondin; Shutao Wang; Fabrice Marquet; Ethan Bunting; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2014-06-20       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.