Literature DB >> 19633465

A guide frame for the Taylor Spatial Frame.

Anastasios D Kanellopoulos1, Andreas F Mavrogenis, Nikolaos D Kanellopoulos, Evangellos A Magnissalis, Panayiotis J Papagelopoulos.   

Abstract

The Taylor Spatial Frame (TSF) is a versatile multiplanar external fixator that combines ease of application with computer accuracy to effectively reduce fractures and correct all aspects of deformity in reconstructive orthopaedic surgery. However, postapplication adjustments depend on adequate anteroposterior and lateral radiographic measurements to yield the most accurate output from the program. These radiographs need to be taken in an orthogonal plane to the reference ring. We describe a noninvasive technique using a specifically designed radiolucent frame that can be attached to the TSF to guide the surgeon and radiologist in obtaining lateral and anteroposterior radiographs, with the reference ring perfectly orthogonal in single exposures for each radiographic view. By using this guiding frame, reproducible and consistent x-rays oriented orthogonally to the reference ring at different points in the correction may be achieved, thus eliminating the need for repeat radiographs and radiation exposure for patients, radiologists, and surgeons. In this manner, the mounting parameters and the orientation of the bony deformity will be consistent. This should lead to enhanced accuracy of the TSF correction.

Entities:  

Mesh:

Year:  2009        PMID: 19633465     DOI: 10.1097/BOT.0b013e3181a24021

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  9 in total

1.  Fracture healing following high energy tibial trauma: Ilizarov versus Taylor Spatial Frame.

Authors:  C U Menakaya; A S Rigby; Y Hadland; E Barron; H Sharma
Journal:  Ann R Coll Surg Engl       Date:  2014-03       Impact factor: 1.891

2.  Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex.

Authors:  Jaco Naude; Muhammad Manjra; Franz F Birkholtz; Annette-Christy Barnard; Vaida Glatt; Kevin Tetsworth; Erik Hohmann
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 Sep-Dec

3.  Distance from the magnification device contributes to differences in lower leg length measured in patients with TSF correction.

Authors:  Marc-Daniel Ahrend; Michael Rühle; Fabian Springer; Heiko Baumgartner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-06       Impact factor: 2.928

4.  The results of bone deformity correction using a spider frame with web-based software for lower extremity long bone deformities.

Authors:  Ali Çağrı Tekin; Haluk Çabuk; Süleyman Semih Dedeoğlu; Mehmet Selçuk Saygılı; Müjdat Adaş; Cem Zeki Esenyel; Cem Dinçay Büyükkurt; Murat Tonbul
Journal:  SICOT J       Date:  2016-03-22

5.  The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator.

Authors:  Jonathan Wright; Shiraz A Sabah; Shelain Patel; Gavin Spence
Journal:  Strategies Trauma Limb Reconstr       Date:  2017-05-12

6.  Two-year clinical and economic burden, risk and outcomes following application of software-assisted hexapod ring fixation systems.

Authors:  J Spence Reid; Mollie Vanderkarr; Bidusee Ray; Abhishek Chitnis; Chantal E Holy; Charisse Sparks
Journal:  BMC Musculoskelet Disord       Date:  2022-01-03       Impact factor: 2.362

7.  Improving postoperative radiographs for the parameter measurement of hexapod external fixator using an additional foot ring.

Authors:  Yanshi Liu; Kai Liu; Feiyu Cai; Tao Zhang; Aihemaitijiang Yusufu
Journal:  J Orthop Surg Res       Date:  2021-11-13       Impact factor: 2.359

8.  Staged correction trajectory with hexapod external fixator for the satisfactory reduction of long bone shaft fracture.

Authors:  Yanshi Liu; Fei Wang; Kai Liu; Feiyu Cai; Xingpeng Zhang; Hong Li; Tao Zhang; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2022-03-08       Impact factor: 2.362

9.  Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.

Authors:  Yanshi Liu; Hong Li; Jialin Liu; Xingpeng Zhang; Maimaiaili Yushan; Zhenhui Liu; Chuang Ma; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-24       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.