| Literature DB >> 27163100 |
Ali Çağrı Tekin1, Haluk Çabuk1, Süleyman Semih Dedeoğlu1, Mehmet Selçuk Saygılı2, Müjdat Adaş1, Cem Zeki Esenyel1, Cem Dinçay Büyükkurt1, Murat Tonbul3.
Abstract
AIM: To present the functional and radiological results and evaluate the effectiveness of a computer-assisted external fixator (spider frame) in patients with lower extremity shortness and deformity.Entities:
Keywords: Computer-assisted software; Deformity correction; Limb shortness treatment
Year: 2016 PMID: 27163100 PMCID: PMC4849258 DOI: 10.1051/sicotj/2016005
Source DB: PubMed Journal: SICOT J ISSN: 2426-8887
Figure 1.Spider Frame correction modes.
Figure 2.An example of a correction prescription.
Figure 3.A 17-year-old male with Perthes disease sequelae and preoperative 4-cm shortness of femur (Case No. 5 in Table 1).
Figure 7.Case No. 6 in Table 1. (a) Varus deformity of femur with preoperative 5-cm shortness, (b) same patient after correction with the Spider Frame, (c) same patient after the removal of Spider Frame.
Master table of all patients.
| No | Sex | Etiology | Deformity | App period of ex-fix | Correction period | Lengthening (cm) | Distraction index (day/cm) | External fixator index (day/cm) | Follow-up period | Paley scale of difficulty | Results of femur | Results of tibia | Functional results of tibia |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | M | Malunion | Shortness | 241 | 50 | 5 | 10 | 48.2 | 31 | 4 | 95 – excellent | ||
| 2 | F | Congenital | Coxa vara 10°, genu varum 10°, shortness | 266 | 60 | 6 | 10 | 44.3 | 17 | 5 | 90 – good | ||
| 3 | F | Malunion | Genu varum 10°, shortness | 240 | 20 | 2 | 10 | 120 | 19 | 6 | 95 – excellent | ||
| 4 | M | Malunion | Genu valgum, shortness | 149 | 30 | 3 | 10 | 49.6 | 14 | 3 | 65 – fair | ||
| 5 | M | Perthess | Shortness | 214 | 40 | 4 | 10 | 53.5 | 13 | 5 | 75 – good | ||
| 6 | M | Malunion | Genu varum 10°, shortness | 210 | 57 | 5 | 11.4 | 42 | 11 | 4 | 80 – good | ||
| 7 | M | Congenital | Genu valgum 14° | 104 | 10 | 1 | 10 | 104 | 12 | 1 | 90 – good | ||
| 8 | M | Congenital | Shortness | 180 | 35 | 3.5 | 10 | 51.4 | 11 | 1 | 95 – excellent | ||
| 9 | M | Congenital | Shortness genu valgus 8° | 150 | 20 | 2 | 10 | 75 | 6 | 7 | 90 – good | ||
| 10 | M | Malunion | Genu varum 20°, procurvatum 10° | 210 | 30 | 3 | 10 | 70 | 14 | 3 | 95 – excellent | ||
| 11 | F | Malunion | Tibial internal rotation 20° | 114 | 13 | 1 | 13 | 114 | 24 | 1 | excellent | excellent | |
| 12 | M | Multiple Enkondromatozis | Tibial procurvatum 30°, valgus 20° | 161 | 10 | 1 | 10 | 161 | 20 | 3 | good | good | |
| 13 | M | Congenital | Shortness | 219 | 40 | 4 | 10 | 54.7 | 19 | 3 | excellent | excellent | |
| 14 | M | Congenital | Shortness | 300 | 50 | 5 | 10 | 60 | 15 | 2 | excellent | excellent | |
| 15 | M | Osteogenesis imperfekta | Tibial procurvatum 10°, varus 10° | 265 | 14 | 1 | 14 | 265 | 16 | 6 | excellent | good | |
| 16 | M | Congenital | Tibial procurvatum 5°, varus 14° | 210 | 10 | 1 | 10 | 210 | 13 | 5 | poor | good | |
| 17 | M | Malunion | Tibial procurvatum 5°, valgus 15° | 213 | 20 | 2 | 10 | 106.5 | 7 | 6 | excellent | excellent |
Figure 8.Spider Frame half pins are laser marked with a depth scale, enabling the surgeon to determine the depth to which the half pin is implanted by checking its scale. The rings in the Spider Frame range from 100 mm to 300 mm. Unlike predicate devices, the Spider Frame ring has double-sided holes on its surface.