Literature DB >> 19631122

Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture.

Daniel Calladine1, Vaughan Tanner.   

Abstract

PURPOSE: To evaluate the effects of stromal hydration on clear corneal incision (CCI) architecture immediately after surgery using anterior segment optical coherence tomography (AS-OCT).
SETTING: Department of Ophthalmology, Royal Berkshire Hospital, Reading, United Kingdom.
METHODS: Clear corneal incisions in adult eyes were examined using a Visante AS-OCT imaging system within 1 hour of surgery. Half the CCIs had stromal hydration with a balanced salt solution and half did not. Incisions were made with a 2.75 mm steel keratome. Intraocular pressure (IOP) was measured within 90 minutes after surgery. The CCI length and corneal thickness at the CCI site were measured using software built into the AS-OCT system.
RESULTS: Thirty CCIs were evaluated. Stromal hydration significantly increased the measured CCI length (P<.05, t test); this was the result of a trend toward increased corneal thickness at the CCI site with hydration (P<.1, t test). The mean CCI length was 1.69 mm +/- 0.27 (SD) (range 1.31 to 2.32 mm) with hydration and 1.51 +/- 0.23 mm (range 1.30 to 1.95 mm) without hydration. The mean IOP was 20.9 +/- 8.18 mm Hg and 15.8 +/- 8.20 mm Hg, respectively. The IOP tended to be higher with hydration (P<.1, t test). Local detachment of Descemet membrane was more likely with stromal hydration (63%) than without (25%).
CONCLUSION: Stromal hydration significantly increased CCI length and tended to leave the eye with a higher early postoperative IOP, showing the importance of taking stromal hydration into account when designing similar OCT studies of CCI architecture.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19631122     DOI: 10.1016/j.jcrs.2009.03.036

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

1.  Intraoperative Optical Coherence Tomography Analysis of Clear Corneal Incision: Effect of the Lateral Stromal Hydration.

Authors:  Jiri Cendelin; Stepan Rusnak; Lenka Hecova
Journal:  J Ophthalmol       Date:  2020-09-08       Impact factor: 1.909

2.  Comparison of Three-Dimensional Surgical System Versus Binocular Microscope for Clear Corneal Incision in Cataract Surgery.

Authors:  Zehui Zhu; Pingjun Chang; Feng Huang; Songqing Shen; Xiaomeng Zhao; Xinpei Ji; Yun E Zhao
Journal:  Ophthalmol Ther       Date:  2022-06-24

3.  Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery.

Authors:  Ken Hayashi; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2014-06-28       Impact factor: 2.447

4.  Safety of air tamponade versus corneal hydration for sealing clear corneal incisions in cataract surgery.

Authors:  Asimina Mataftsi; Maria Dermenoudi; Artemis Matsou; Argyrios Tzamalis; Periklis Brazitikos; Persefoni Talimtzi; Nikolaos Ziakas; Ioannis T Tsinopoulos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-18       Impact factor: 3.117

5.  The effect of stromal hydration on surgical outcomes for cataract patients who received a hydrogel ocular bandage.

Authors:  Thomas R Walters
Journal:  Clin Ophthalmol       Date:  2011-03-20

Review 6.  Cataract surgery and methods of wound closure: a review.

Authors:  Cynthia Matossian; Sarah Makari; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-05-22

7.  Structural analysis of different incision sizes and stromal hydration in cataract surgery using anterior segment optical coherence tomography.

Authors:  Jong-Wook Bang; Jong-Hyun Lee; Jin-Hyoung Kim; Do-Hyung Lee
Journal:  Korean J Ophthalmol       Date:  2015-01-22

8.  Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector with/without Pause Time and a Manual Injector.

Authors:  Hisanori Imai; Ayaka Fujii; Emiko Tani; Atsushi Azumi
Journal:  J Ophthalmol       Date:  2016-02-17       Impact factor: 1.909

9.  Real-time Optical Coherence Tomography Incorporated in the Operating Microscope during Cataract Surgery.

Authors:  Mohammed A Almutlak; Turki Aloniazan; William May
Journal:  Middle East Afr J Ophthalmol       Date:  2017 Jul-Sep

10.  Irrigation port hydration in phacoemulsification surgery.

Authors:  Hisaharu Suzuki; Yoichiro Masuda; Yuki Hamajima; Hiroshi Takahashi
Journal:  Clin Ophthalmol       Date:  2018-01-17
  10 in total