Literature DB >> 23412263

Clinical results of arthroscopic all-inside lateral meniscal repair using the Meniscal Viper Repair System.

Tetsuo Hagino1, Satoshi Ochiai, Yoshiyuki Watanabe, Shinya Senga, Masanori Wako, Takashi Ando, Eiichi Sato, Hirotaka Haro.   

Abstract

PURPOSE: This study examined the postoperative outcome of the all-inside arthroscopic meniscal suture repair technique using the Meniscal Viper Repair System for lateral meniscus tears.
METHODS: Between January 2006 and December 2008, 57 patients (27 males and 30 females) with lateral meniscus tears who underwent meniscal repair using the Meniscal Viper Repair System were evaluated prospectively. Among them, 52 cases were tears involving the posterior third of the lateral meniscus, and most were longitudinal tears or bucket handle tears. The postoperative follow-up period ranged from 12 months to 4 years and 2 months, and averaged 19 months.
RESULTS: Both Lysholm and Japanese Orthopaedic Association Score were significantly improved after surgery. Forty-nine of 57 patients (86.0 %) had no locking or catching, no joint line tenderness, and a negative McMurray test at the last follow-up. Of 32 patients who underwent second-look arthroscopy, 24 achieved complete healing, while four showed partial healing and required repeat repair, and four showed no healing and meniscectomy was conducted. The failure rate in all patients was thus 14.0 % (8 of 57 repairs). No major complications associated with the use of the Meniscal Viper Repair System were observed.
CONCLUSION: The Meniscal Viper System is a convenient and effective device for all- inside lateral meniscal suture, with high success rate and no major complications.

Entities:  

Mesh:

Year:  2012        PMID: 23412263     DOI: 10.1007/s00590-012-1138-1

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  38 in total

1.  Review of the clinical results of arthroscopic meniscal repair.

Authors:  S Venkatachalam; S P Godsiff; M L Harding
Journal:  Knee       Date:  2001-06       Impact factor: 2.199

2.  Deteriorating outcomes after meniscal repair using the Meniscus Arrow in knees undergoing concurrent anterior cruciate ligament reconstruction: increased failure rate with long-term follow-up.

Authors:  Gregory P Lee; David R Diduch
Journal:  Am J Sports Med       Date:  2005-07-06       Impact factor: 6.202

3.  All-inside suture technique using anterior portals in posterior horn tears of lateral meniscus.

Authors:  Alejandro Espejo-Baena; Alejandro Figueroa-Mata; José Serrano-Fernández; Francisco de la Torre-Solís
Journal:  Arthroscopy       Date:  2007-10-03       Impact factor: 4.772

4.  Second-look arthroscopic evaluation of bucket-handle meniscus tear repairs with anterior cruciate ligament reconstruction: 67 consecutive cases.

Authors:  Hua Feng; Lei Hong; Xiang-su Geng; Hui Zhang; Xue-song Wang; Xie-yuan Jiang
Journal:  Arthroscopy       Date:  2008-09-13       Impact factor: 4.772

5.  Biomechanical evaluation of arthroscopic all-inside meniscus repairs.

Authors:  Taner Gunes; Bora Bostan; Mehmet Erdem; Murat Asci; Cengiz Sen; Mehmet Halidun Kelestemur
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

Review 6.  Arthroscopic meniscal repair.

Authors:  D E Cooper; S P Arnoczky; R F Warren
Journal:  Clin Sports Med       Date:  1990-07       Impact factor: 2.182

7.  Rating systems in the evaluation of knee ligament injuries.

Authors:  Y Tegner; J Lysholm
Journal:  Clin Orthop Relat Res       Date:  1985-09       Impact factor: 4.176

8.  Meniscal repair using the FasT-Fix all-inside meniscal repair device.

Authors:  Andrew L Haas; Anthony A Schepsis; Joshua Hornstein; Cory M Edgar
Journal:  Arthroscopy       Date:  2005-02       Impact factor: 4.772

9.  Arthroscopic all-inside suture repair of medial meniscus lesion in anterior cruciate ligament--deficient knees: results of second-look arthroscopies in 39 cases.

Authors:  Jin Hwan Ahn; Joon Ho Wang; Jae Chul Yoo
Journal:  Arthroscopy       Date:  2004-11       Impact factor: 4.772

10.  "All-inside" meniscal repair devices: an experimental study in the goat model.

Authors:  Mark D Miller; Alex J Kline; Kerry G Jepsen
Journal:  Am J Sports Med       Date:  2004-06       Impact factor: 6.202

View more
  5 in total

1.  Arthroscopic meniscus repair for recurrent subluxation of the lateral meniscus.

Authors:  Jin Hwan Ahn; Sang Hak Lee; Kang Il Kim; Juhyun Nam
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-03       Impact factor: 4.342

2.  The best cited articles of the European Journal of Orthopaedic Surgery and Traumatology (EJOST): a bibliometric analysis.

Authors:  Andreas F Mavrogenis; Panayiotis D Megaloikonomos; Cyril Mauffrey; Marius M Scarlat; Patrick Simon; Kazuhiro Hasegawa; Samo K Fokter; Pierre Kehr
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-02-14

3.  Arthroscopic repair of bucket-handle tears of the lateral meniscus.

Authors:  Jin Hwan Ahn; Kang-Il Kim; Joon Ho Wang; Bong Soo Kyung; Min Chul Seo; Sang Hak Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-09       Impact factor: 4.342

Review 4.  Second-Look Arthroscopic Evaluation of Healing Rates After Arthroscopic Repair of Meniscal Tears: A Systematic Review and Meta-analysis.

Authors:  Wenli Dai; Xi Leng; Jian Wang; Xiaoqing Hu; Yingfang Ao
Journal:  Orthop J Sports Med       Date:  2021-10-22

5.  The Results of All-Inside Meniscus Repair Using the Viper Repair System Simultaneously with Anterior Cruciate Ligament Reconstruction.

Authors:  Hong Je Kang; Churl Hong Chun; Kwang Mee Kim; Hang Hwan Cho; Johnsel C Espinosa
Journal:  Clin Orthop Surg       Date:  2015-05-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.