Literature DB >> 19628391

Reproducibility of spatio-temporal gait parameters under different conditions in older adults using a trunk tri-axial accelerometer system.

Antonia Hartmann1, Kurt Murer, Rob A de Bie, Eling D de Bruin.   

Abstract

The aim of this study was to determine intra- and interrater reliability of spatio-temporal gait parameters on different walking surfaces and under dual task conditions in an older adult population using a trunk tri-axial accelerometer (DynaPort((MiniMod)) system. Twenty-three independent living, older subjects (8 males, 15 females) aged 73.4+/-4.3 years walked three times at their preferred walking speed in two test sessions under four different conditions over 24 m (gymnasium floor versus soft foam rubber walkway, with both normal and dual task walking conditions). Inter- and intrarater reliability was assessed. Subsequently intraclass correlation coefficients (ICC), coefficients of variation (CV) and ratios limits of agreement (RLOA) were calculated. The reliability of walking speed, cadence, step duration and step length was excellent with high ICCs and small CVs and RLOAs. ICCs of gait variability ranged from 0.12 to 0.88. The corresponding CVs ranged from 12% to 34% and RLOAs from 35% to 93% and appeared relatively large. The results of this study demonstrate that walking speed, cadence, step duration and step length under more challenging conditions can be reliably measured in independent living older adults using the DynaPort(MiniMod) system. Gait variability measures need to be viewed with caution and further research in older populations is needed to determine the value of these parameters derived from this measurement system.

Mesh:

Year:  2009        PMID: 19628391     DOI: 10.1016/j.gaitpost.2009.06.008

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  26 in total

1.  Inertial sensors in estimating walking speed and inclination: an evaluation of sensor error models.

Authors:  Shuozhi Yang; Annemarie Laudanski; Qingguo Li
Journal:  Med Biol Eng Comput       Date:  2012-03-15       Impact factor: 2.602

Review 2.  [Assessment and training of strength and balance for fall prevention in the elderly: recommendations of an interdisciplinary expert panel].

Authors:  U Granacher; T Muehlbauer; Y J Gschwind; B Pfenninger; R W Kressig
Journal:  Z Gerontol Geriatr       Date:  2014-08       Impact factor: 1.281

3.  Understanding the effects of pre-processing on extracted signal features from gait accelerometry signals.

Authors:  Alexandre Millecamps; Kristin A Lowry; Jennifer S Brach; Subashan Perera; Mark S Redfern; Ervin Sejdić
Journal:  Comput Biol Med       Date:  2015-04-04       Impact factor: 4.589

Review 4.  The promise of mHealth: daily activity monitoring and outcome assessments by wearable sensors.

Authors:  Bruce H Dobkin; Andrew Dorsch
Journal:  Neurorehabil Neural Repair       Date:  2011 Nov-Dec       Impact factor: 3.919

5.  Sensor-based foot-mounted wearable system and pressure sensitive gait analysis : Agreement in frail elderly people in long-term care.

Authors:  Slavko Rogan; Rob de Bie; Eling Douwe de Bruin
Journal:  Z Gerontol Geriatr       Date:  2016-09-06       Impact factor: 1.281

Review 6.  Advancing measurement of locomotor rehabilitation outcomes to optimize interventions and differentiate between recovery versus compensation.

Authors:  Mark G Bowden; Andrea L Behrman; Michelle Woodbury; Chris M Gregory; Craig A Velozo; Steven A Kautz
Journal:  J Neurol Phys Ther       Date:  2012-03       Impact factor: 3.649

Review 7.  Gait metrics analysis utilizing single-point inertial measurement units: a systematic review.

Authors:  Ralph Jasper Mobbs; Jordan Perring; Suresh Mahendra Raj; Monish Maharaj; Nicole Kah Mun Yoong; Luke Wicent Sy; Rannulu Dineth Fonseka; Pragadesh Natarajan; Wen Jie Choy
Journal:  Mhealth       Date:  2022-01-20

8.  A comprehensive assessment of gait accelerometry signals in time, frequency and time-frequency domains.

Authors:  Ervin Sejdić; Kristin A Lowry; Jennica Bellanca; Mark S Redfern; Jennifer S Brach
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2013-06-06       Impact factor: 3.802

9.  The test-retest reliability and minimal detectable change of spatial and temporal gait variability during usual over-ground walking for younger and older adults.

Authors:  Maha Almarwani; Subashan Perera; Jessie M VanSwearingen; Patrick J Sparto; Jennifer S Brach
Journal:  Gait Posture       Date:  2015-11-30       Impact factor: 2.840

Review 10.  Wearable motion sensors to continuously measure real-world physical activities.

Authors:  Bruce H Dobkin
Journal:  Curr Opin Neurol       Date:  2013-12       Impact factor: 5.710

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.