Literature DB >> 19623098

Piezoelectric round window osteoplasty for Vibrant Soundbridge implant.

Domenico Cuda1, Alessandra Murri, Nicoletta Tinelli.   

Abstract

OBJECTIVE: To evaluate the Piezosurgery (PZS) ultrasonic bone dissector as an alternative to conventional drilling to implant the Vibrant Soundbridge transducer in the round window (RW) niche. STUDY
DESIGN: Prospective noncontrolled study. Audiologic and surgical records analysis.
METHODS: Eight patients with mixed hearing loss and previous unsuccessful otologic surgeries were recruited. A transcanal or transmastoid approach was used. Round window osteoplasty was performed with the PZS device to implant the VBS floating mass transducer for cochlear stimulation.
RESULTS: The osteoplasty was performed safely with PZS, and all patients were successfully implanted. No sensorineural hearing deterioration occurred in all but 1 patient. The postoperative air conduction threshold was slightly higher than preoperatively because of minor middle ear transfer function changes. After fitting, patients continue to wear their speech processors full-time. The aided speech discrimination scores at conversational level ranged from 65 to 100%. Aided hearing threshold was 32.2 dB HL (preoperative threshold under earphones, 62.8 dB HL). One patient affected by congenital aural atresia had a posterior canalithiosis on the operated side that was successfully treated by the repositioning maneuver.
CONCLUSION: The PZS device proved to be effective for RW osteoplasty; floating mass transducer was successfully implanted in all patients. Audiologic results are comparable to those obtained from traditionally operated patients. Relative to conventional drilling, the PZS allows a safer osteoplasty because it does not produce any rotation or torque that reduces the risk of RW membrane injury. Although hearing was preserved in our sample, the potential inner ear risks need to be further evaluated in both experimental and clinical fields.

Entities:  

Mesh:

Year:  2009        PMID: 19623098     DOI: 10.1097/MAO.0b013e3181b04d4d

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  5 in total

1.  Measurement of basilar membrane motion during round window stimulation in guinea pigs.

Authors:  Yongzheng Chen; Xiying Guan; Tianyu Zhang; Rong Z Gan
Journal:  J Assoc Res Otolaryngol       Date:  2014-08-01

2.  The floating mass transducer on the round window versus attachment to an ossicular replacement prosthesis.

Authors:  Yoshitaka Shimizu; Sunil Puria; Richard L Goode
Journal:  Otol Neurotol       Date:  2011-01       Impact factor: 2.311

Review 3.  [Piezoelectric ear surgery: a systematic review. German version].

Authors:  Stefan Lyutenski; Anja Lieder; Marc Bloching
Journal:  HNO       Date:  2022-08-12       Impact factor: 1.330

Review 4.  Piezoelectric ear surgery: a systematic review.

Authors:  Stefan Lyutenski; Anja Lieder; Marc Bloching
Journal:  HNO       Date:  2022-10-07       Impact factor: 1.330

5.  Ultrasonic bone removal from the ossicular chain affects cochlear structure and function.

Authors:  Jennifer M Siu; Jaina Negandhi; Robert V Harrison; Nikolaus E Wolter; Adrian James
Journal:  J Otolaryngol Head Neck Surg       Date:  2021-04-02
  5 in total