Literature DB >> 25080894

Measurement of basilar membrane motion during round window stimulation in guinea pigs.

Yongzheng Chen1, Xiying Guan, Tianyu Zhang, Rong Z Gan.   

Abstract

Driving the cochlea in reverse via the round window membrane (RWM) is an alternative treatment option for the hearing rehabilitation of a nonfunctional or malformed middle ear. However, cochlear stimulation from the RWM side is not a normal sound transmission pathway. The basilar membrane (BM) motion elicited by mechanical stimulation of the RWM is unknown. In this study, the BM movement at the basal turn was investigated in both reverse via RWM drive and acoustic stimulation in the ear canal or forward drive in postmortem isolated temporal bone preparations of guinea pigs. During reverse drive, a magnet-coil was coupled on RWM, and the BM vibration at the basal turn and the movement of the incus tip were measured with laser Doppler vibrometry. During forward drive, the vibration of the incus tip induced by sound pressure in the ear canal resulted in BM vibration and the BM movement at the same location as that in the reverse stimulation was measured. The displacement ratio of the BM to RWM in reverse drive and the ratio of the BM to incus in forward drive were compared. The results demonstrated that the BM response measured in both situations was similar in nature between forward and reverse drives. This study provides new knowledge for an understanding of BM movement induced by reverse drive via the RWM stimulation.

Entities:  

Mesh:

Year:  2014        PMID: 25080894      PMCID: PMC4389955          DOI: 10.1007/s10162-014-0477-5

Source DB:  PubMed          Journal:  J Assoc Res Otolaryngol        ISSN: 1438-7573


  26 in total

1.  Basilar membrane vibration in the basal turn of the sensitive gerbil cochlea.

Authors:  T Ren; A L Nuttall
Journal:  Hear Res       Date:  2001-01       Impact factor: 3.208

2.  Characteristics of the travelling wave in the low-frequency region of a temporal-bone preparation of the guinea-pig cochlea.

Authors:  W Hemmert; H Zenner; A W Gummer
Journal:  Hear Res       Date:  2000-04       Impact factor: 3.208

3.  Three-dimensional stapes footplate motion in human temporal bones.

Authors:  Naohito Hato; Stefan Stenfelt; Richard L Goode
Journal:  Audiol Neurootol       Date:  2003 May-Jun       Impact factor: 1.854

4.  Application of a commercially-manufactured Doppler-shift laser velocimeter to the measurement of basilar-membrane vibration.

Authors:  M A Ruggero; N C Rich
Journal:  Hear Res       Date:  1991-02       Impact factor: 3.208

5.  Laser Doppler velocimetry of basilar membrane vibration.

Authors:  A L Nuttall; D F Dolan; G Avinash
Journal:  Hear Res       Date:  1991-02       Impact factor: 3.208

Review 6.  The round window electromagnetic implantable hearing aid approach.

Authors:  J H Spindel; P R Lambert; R A Ruth
Journal:  Otolaryngol Clin North Am       Date:  1995-02       Impact factor: 3.346

7.  Observations of the vibration of the basilar membrane in squirrel monkeys using the Mössbauer technique.

Authors:  W S Rhode
Journal:  J Acoust Soc Am       Date:  1971-04       Impact factor: 1.840

8.  Effect of middle ear fluid on sound transmission and auditory brainstem response in guinea pigs.

Authors:  Xiying Guan; Rong Z Gan
Journal:  Hear Res       Date:  2011-03-21       Impact factor: 3.208

9.  Comparison of forward (ear-canal) and reverse (round-window) sound stimulation of the cochlea.

Authors:  Christof Stieger; John J Rosowski; Hideko Heidi Nakajima
Journal:  Hear Res       Date:  2012-11-14       Impact factor: 3.208

10.  Piezoelectric middle ear implant preserving the ossicular chain.

Authors:  T Dumon; O Zennaro; J M Aran; J P Bébéar
Journal:  Otolaryngol Clin North Am       Date:  1995-02       Impact factor: 3.346

View more
  4 in total

1.  Development of the head, pinnae, and acoustical cues to sound location in a precocial species, the guinea pig (Cavia porcellus).

Authors:  Kelsey L Anbuhl; Victor Benichoux; Nathaniel T Greene; Andrew D Brown; Daniel J Tollin
Journal:  Hear Res       Date:  2017-11-01       Impact factor: 3.208

2.  Effect of Endolymphatic Hydrops on Sound Transmission in Live Guinea Pigs Measured with a Laser Doppler Vibrometer.

Authors:  Chen-Ru Ding; Xin-Da Xu; Xin-Wei Wang; Xian-Hao Jia; Xiang Cheng; Xiang Liu; Lin Yang; Bu-Sheng Tong; Fang-Lu Chi; Dong-Dong Ren
Journal:  Neural Plast       Date:  2016-12-14       Impact factor: 3.599

3.  The Influence of Piezoelectric Transducer Stimulating Sites on the Performance of Implantable Middle Ear Hearing Devices: A Numerical Analysis.

Authors:  Houguang Liu; Yu Zhao; Jianhua Yang; Zhushi Rao
Journal:  Micromachines (Basel)       Date:  2019-11-14       Impact factor: 2.891

Review 4.  Round Window Stimulation of the Cochlea.

Authors:  Herman A Jenkins; Nathaniel Greene; Daniel J Tollin
Journal:  Front Neurol       Date:  2021-12-14       Impact factor: 4.003

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.