Literature DB >> 1961159

Coronary blood flow measurement using an angiographic first pass distribution technique: a feasibility study.

N J Hangiandreou1, J D Folts, W W Peppler, C A Mistretta.   

Abstract

Due to the well-documented problems associated with visual interpretation of coronary angiograms, more physiologic means of assessing coronary artery stenosis are being investigated. One physiologic parameter that has been suggested is coronary flow reserve (CFR). A digital subtraction angiographic technique based on first pass distribution analysis (FPA) is proposed as a means of measuring CFR and absolute coronary flow. The theory of the FPA method is first outlined, and the implementation of a preliminary version of the FPA algorithm is described. Experiments verifying the utility of this algorithm for measuring absolute flow through a flow phantom, and through the canine circumflex artery are reported. It was determined that the preliminary FPA algorithm is capable of measuring canine coronary flow ratios (R) with accuracy and precision characteristics meeting or exceeding those reported for the parametric imaging technique (RFPA = 0.933.Rtrue, SEE = 0.16, r = 0.984). Accurate absolute flow (Q) measurements were obtained in all of the phantom experiments (QFPA = 1.054.Qtrue, r = 0.993), and in one of the three dogs that were studied (QFPA = 0.977.Qtrue, r = 0.935). The difficulty encountered in the other two dog experiments is attributed to the effects of system temporal lag, and would likely be corrected through the use of improved cameras. The feasibility of the general FPA method for measuring relative flow is established, and the potential for routine, absolute flow measurement is demonstrated.

Entities:  

Mesh:

Year:  1991        PMID: 1961159     DOI: 10.1118/1.596716

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Absolute volumetric coronary blood flow measurement with digital subtraction angiography.

Authors:  S Molloi; G Bednarz; J Tang; Y Zhou; T Mathur
Journal:  Int J Card Imaging       Date:  1998-06

2.  Quantification of coronary microvascular resistance using angiographic images for volumetric blood flow measurement: in vivo validation.

Authors:  Zhang Zhang; Shigeho Takarada; Sabee Molloi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-03-11       Impact factor: 4.733

3.  Improved densitometric measurement of left ventricular ejection fraction using dual-energy digital subtraction angiography.

Authors:  M S van Lysel; W P Miller; T P Fuerst; D J Albright
Journal:  Int J Card Imaging       Date:  1994-06

4.  Quantification of fractional flow reserve based on angiographic image data.

Authors:  Jerry T Wong; Huy Le; William M Suh; David A Chalyan; Toufan Mehraien; Morton J Kern; Ghassan S Kassab; Sabee Molloi
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-07       Impact factor: 2.357

5.  Estimation of coronary artery hyperemic blood flow based on arterial lumen volume using angiographic images.

Authors:  Sabee Molloi; David Chalyan; Huy Le; Jerry T Wong
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-07       Impact factor: 2.357

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.