Abstract

Radiochromic film is a dosimeter of choice in applications requiring high spatial resolution, two dimensional measurements, or minimum perturbation of the beam fluence. Since the measurement uncertainty in Gafchromic film dosimetry is thought to be significant compared to that of ionization chambers, a rigorous method to evaluate measurement uncertainties is desired. This article provides a method that takes into account the correlation between fit parameters as well as single dose values in order to obtain accurate uncertainties in absolute and relative measurements. A complete portrait of all sources of uncertainty in Gafchromic film dosimetry is given. The parametrization of variance as a function of the number of averaged pixels is obtained in order to accurately predict the uncertainty as a function of the size of the region of interest. The choice of functional form for the sensitometric curve is based on four criteria and a convergence of global net optical density uncertainty to 0.0013 is demonstrated. A minimum number of 12 points is recommended to characterize the sensitometric curve to a sufficient precision on the uncertainty estimation. Uncertainty levels of 0.9% on absolute dose measurements and 0.45% on relative measurements are achieved using a 12-point calibration curve with 220 cGy and repeating measurements five times. Uncertainties of 0.8% and 0.4% are achievable when using 35 points during film characterization. Ignoring covariance terms is shown to lead to errors in the estimation of uncertainty.

Entities:  

Mesh:

Year:  2009        PMID: 19610282     DOI: 10.1118/1.3121488

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.

Authors:  Frédéric Lacroix; Mathieu Guillot; Malcolm McEwen; Claudiu Cojocaru; Luc Gingras; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 3.  Complexity metrics for IMRT and VMAT plans: a review of current literature and applications.

Authors:  Sophie Chiavassa; Igor Bessieres; Magali Edouard; Michel Mathot; Alexandra Moignier
Journal:  Br J Radiol       Date:  2019-07-24       Impact factor: 3.039

4.  SBRT/SRS patient-specific QA using GAFchromicTM EBT3 and FilmQATM Pro software.

Authors:  Giuseppe Stella; Nina Cavalli; Elisa Bonanno; Lucia Zirone; Giuseppina Rita Borzì; Martina Pace; Andrea Girlando; Anna M Gueli; Carmelo Marino
Journal:  J Radiosurg SBRT       Date:  2022

5.  Computation of epistemic uncertainty due to limited data samples in small field dosimetry using Fuzzy Set Theory.

Authors:  Rahul Kumar Chaudhary; Rajesh Kumar; S D Sharma; D Datta
Journal:  Br J Radiol       Date:  2021-03-18       Impact factor: 3.039

6.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

Authors:  David Lewis; Andre Micke; Xiang Yu; Maria F Chan
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

7.  3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry.

Authors:  A R Barbeiro; A Ureba; J A Baeza; R Linares; M Perucha; E Jiménez-Ortega; S Velázquez; J C Mateos; A Leal
Journal:  PLoS One       Date:  2016-11-21       Impact factor: 3.240

8.  Evaluation of triple channel correction acquisition method for radiochromic film dosimetry.

Authors:  Naoki Hayashi; Yoichi Watanabe; Ryan Malmin; Hideki Kato
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

9.  Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

Authors:  Francis Viel; Richard Lee; Ermias Gete; Cheryl Duzenli
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

10.  Probability Distribution of Pixel Intensities of EBT3 Films and its Application in the Correction of Uncertainty Budget.

Authors:  Rahul Kumar Chaudhary; Munir Pathan; Rajesh Kumar; S D Sharma; B K Sapra
Journal:  J Med Phys       Date:  2021-05-05