Literature DB >> 19608367

High-definition, single-scan 2D MRI in inhomogeneous fields using spatial encoding methods.

Noam Ben-Eliezer1, Yoav Shrot, Lucio Frydman.   

Abstract

An approach has been recently introduced for acquiring two-dimensional (2D) nuclear magnetic resonance images in a single scan, based on the spatial encoding of the spin interactions. This article explores the potential of integrating this spatial encoding together with conventional temporal encoding principles, to produce 2D single-shot images with moderate field of views. The resulting "hybrid" imaging scheme is shown to be superior to traditional schemes in non-homogeneous magnetic field environments. An enhancement of previously discussed pulse sequences is also proposed, whereby distortions affecting the image along the spatially encoded axis are eliminated. This new variant is also characterized by a refocusing of T(2)(*) effects, leading to a restoration of high-definition images for regions which would otherwise be highly dephased and thus not visible. These single-scan 2D images are characterized by improved signal-to-noise ratios and a genuine T(2) contrast, albeit not free from inhomogeneity distortions. Simple postprocessing algorithms relying on inhomogeneity phase maps of the imaged object can successfully remove most of these residual distortions. Initial results suggest that this acquisition scheme has the potential to overcome strong field inhomogeneities acting over extended acquisition durations, exceeding 100 ms for a single-shot image.

Entities:  

Mesh:

Year:  2009        PMID: 19608367     DOI: 10.1016/j.mri.2009.05.026

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  21 in total

1.  MRI by steering resonance through space.

Authors:  Angela L S Snyder; Curtis A Corum; Steen Moeller; Nathaniel J Powell; Michael Garwood
Journal:  Magn Reson Med       Date:  2013-08-01       Impact factor: 4.668

2.  Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants.

Authors:  Noam Ben-Eliezer; Eddy Solomon; Elad Harel; Nava Nevo; Lucio Frydman
Journal:  MAGMA       Date:  2012-06-29       Impact factor: 2.310

3.  Alleviating artifacts in 1H MRI thermometry by single scan spatiotemporal encoding.

Authors:  Rita Schmidt; Lucio Frydman
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310

4.  Stages: sub-Fourier dynamic shim updating using nonlinear magnetic field phase preparation.

Authors:  Walter Rt Witschey; Sebastian Littin; Chris A Cocosco; Daniel Gallichan; Gerrit Schultz; Hans Weber; Anna Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

5.  Spatial specificity in spatiotemporal encoding and Fourier imaging.

Authors:  Ute Goerke
Journal:  Magn Reson Imaging       Date:  2015-12-19       Impact factor: 2.546

6.  Spatiotemporal encoding as a robust basis for fast three-dimensional in vivo MRI.

Authors:  Noam Ben-Eliezer; Lucio Frydman
Journal:  NMR Biomed       Date:  2011-02-28       Impact factor: 4.044

7.  High fidelity magnetic resonance imaging by frequency sweep encoding and Fourier decoding.

Authors:  Jun Shen; Yun Xiang
Journal:  J Magn Reson       Date:  2010-02-20       Impact factor: 2.229

8.  Functional MRI using super-resolved spatiotemporal encoding.

Authors:  Noam Ben-Eliezer; Ute Goerke; Kamil Ugurbil; Lucio Frydman
Journal:  Magn Reson Imaging       Date:  2012-07-11       Impact factor: 2.546

9.  New spatiotemporal approaches for fully refocused, multislice ultrafast 2D MRI.

Authors:  Rita Schmidt; Lucio Frydman
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Diffusion weighted MRI by spatiotemporal encoding: analytical description and in vivo validations.

Authors:  Eddy Solomon; Noam Shemesh; Lucio Frydman
Journal:  J Magn Reson       Date:  2013-03-14       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.