Literature DB >> 19603200

Randomised study for the 1-year crestal bone maintenance around modified diameter implants with different loading protocols: a radiographic evaluation.

Matteo Danza1, Pietro Tortora, Alessandro Quaranta, Vittoria Perrotti, Iole Vozza, Adriano Piattelli.   

Abstract

This study evaluated by standardised digitised periapical radiography the crestal bone maintenance around modified diameter internal hex implants with variable thread design and narrow neck loaded with different procedures. Forty implants were placed in 25 patients. Twenty implants were conventionally loaded, 20 ones immediately loaded. Radiographs were taken with a customised bite record and processed with software. Measurements of bone from the fixture-abutment junction to mesial and distal marginal bone levels were made. Student's t test statistical analysis was adopted. Baseline data were variable; at 1-year follow-up, there were no significant differences for marginal bone loss between immediately and conventionally loaded maxillary implants (p = 0.1031), whilst there were slight significant differences between immediately and conventionally loaded implants in the mandible (p = 0.0141). Crestal bone maintenance around conventionally and immediately loaded modified diameter implants was similar, with slight significant differences in mandible where a lower marginal bone loss was observed.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19603200     DOI: 10.1007/s00784-009-0314-0

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  44 in total

1.  Immediate functional loading of Brånemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study.

Authors:  Roberto Calandriello; Massimiliano Tomatis; Bo Rangert
Journal:  Clin Implant Dent Relat Res       Date:  2003       Impact factor: 3.932

2.  Scalloped implant designs enhance interproximal bone levels.

Authors:  Bradley S McAllister
Journal:  Int J Periodontics Restorative Dent       Date:  2007-02       Impact factor: 1.840

3.  Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels.

Authors:  Richard J Lazzara; Stephan S Porter
Journal:  Int J Periodontics Restorative Dent       Date:  2006-02       Impact factor: 1.840

4.  Immediate function with NobelPerfect implants in the anterior dental arch.

Authors:  Robert Noelken; Thomas Morbach; Martin Kunkel; Wilfried Wagner
Journal:  Int J Periodontics Restorative Dent       Date:  2007-06       Impact factor: 1.840

5.  A comparative prospective clinical study of two single-tooth implants: a preliminary report of 102 implants.

Authors:  P Kemppainen; S Eskola; P Ylipaavalniemi
Journal:  J Prosthet Dent       Date:  1997-04       Impact factor: 3.426

Review 6.  The long-term efficacy of currently used dental implants: a review and proposed criteria of success.

Authors:  T Albrektsson; G Zarb; P Worthington; A R Eriksson
Journal:  Int J Oral Maxillofac Implants       Date:  1986       Impact factor: 2.804

7.  On functional strain in fixed mandibular reconstructions. I. An in vitro study.

Authors:  P O Glantz; E Strandman; S A Svensson; K Randow
Journal:  Acta Odontol Scand       Date:  1984-08       Impact factor: 2.331

8.  A 3-year prospective clinical and radiologic analysis of early loaded maxillary dental implants supporting single-tooth crowns.

Authors:  Ilser Turkyilmaz
Journal:  Int J Prosthodont       Date:  2006 Jul-Aug       Impact factor: 1.681

9.  The radiographic bone loss pattern adjacent to immediately placed, immediately loaded implants.

Authors:  Robert Jaffin; Matthew Kolesar; Akshay Kumar; Satoshi Ishikawa; Joseph Fiorellini
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Mar-Apr       Impact factor: 2.804

10.  Immediately loaded titanium implant with a tissue-stabilizing/maintaining design ('beyond platform switch') retrieved from man after 4 weeks: a histological and histomorphometrical evaluation. A case report.

Authors:  Marco Degidi; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Clin Oral Implants Res       Date:  2007-12-13       Impact factor: 5.977

View more
  4 in total

1.  Changes in mastication after an immediate loading implantation with complete fixed rehabilitation.

Authors:  J L Veyrune; S Opé; E Nicolas; A Woda; M Hennequin
Journal:  Clin Oral Investig       Date:  2012-07-20       Impact factor: 3.573

2.  A case report of a TPS dental implant rigidly connected to a natural tooth: 19-year follow-up.

Authors:  Alessandro Quaranta; Ottavia Poli; Iole Vozza
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

3.  Radiographic Evaluation of Crestal Bone Loss Around Dental Implants in Maxilla and Mandible: One Year Prospective Clinical Study.

Authors:  Muhamed Ajanović; Adis Hamzić; Sead Redžepagić; Alma Kamber-Ćesir; Lejla Kazazić; Selma Tosum
Journal:  Acta Stomatol Croat       Date:  2015-06

4.  A comparative analysis of periimplant bone levels of immediate and conventionally loaded implants.

Authors:  G K Thapliyal; V R Pawar
Journal:  Med J Armed Forces India       Date:  2012-09-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.