Literature DB >> 19596591

Comparative evaluation of the fecal-tagging quality in CT colonography: barium vs. iodinated oral contrast agent.

Koichi Nagata1, Anand Kumar Singh, Minal Jagtiani Sangwaiya, Janne Näppi, Michael E Zalis, Wenli Cai, Hiroyuki Yoshida.   

Abstract

RATIONALE AND
OBJECTIVES: The purpose of this evaluation was to compare the tagging quality of a barium-based regimen with that of iodine-based regimens for computed tomographic (CT) colonography.
MATERIALS AND METHODS: Tagging quality was assessed retrospectively in three different types of fecal-tagging CT colonographic cases: 24 barium-based cases, 22 nonionic iodine-based cases, and 24 ionic iodine-based cases. For the purpose of evaluation, the large intestine was divided into six segments, and the tagging homogeneity of a total of 420 segments (70 patients) was graded by three blinded readers from 0 (heterogeneous) to 4 (homogeneous).
RESULTS: For barium-based cases, the average score for the three readers was 2.4, whereas it was 3.4 for nonionic iodine and 3.6 for ionic iodine. The percentages of segments that were assigned scores of 4 (excellent tagging [100%]) were 11.6%, 61.9%, and 72.9% for the barium-based, nonionic iodine-based, and ionic iodine-based regimens, respectively. The homogeneity scores of iodine-based fecal-tagging regimens were significantly higher than those of the barium-based fecal-tagging regimen (P < .001). The CT attenuation values of tagging in the cases were also assessed: the minimum and maximum values were significantly higher for the iodine-based regimens than for the barium-based regimen (P < .001).
CONCLUSIONS: The iodine-based fecal-tagging regimens provide significantly greater homogeneity in oral-tagging fecal material than the barium-based fecal-tagging regimen. Iodine-based fecal-tagging regimens can provide an appropriate method for use in nonlaxative or minimum-laxative CT colonography.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19596591     DOI: 10.1016/j.acra.2009.05.003

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  9 in total

1.  Laxative-free CT colonography.

Authors:  A Slater; M Betts; H D'Costa
Journal:  Br J Radiol       Date:  2011-12-13       Impact factor: 3.039

2.  Biodegradable iodinated polydisulfides as contrast agents for CT angiography.

Authors:  Erlei Jin; Zheng-Rong Lu
Journal:  Biomaterials       Date:  2014-04-24       Impact factor: 12.479

Review 3.  Computed tomography colonography for the practicing radiologist: A review of current recommendations on methodology and clinical indications.

Authors:  Paola Scalise; Annalisa Mantarro; Francesca Pancrazi; Emanuele Neri
Journal:  World J Radiol       Date:  2016-05-28

4.  Fecal tag CT colonography with a limited 2-day bowel preparation following incomplete colonoscopy.

Authors:  Kaan Meric; Nuray Bakal; Sibel Aydin; Atakan Yesil; Kemal Tekesin; Masum Simsek
Journal:  Jpn J Radiol       Date:  2015-04-21       Impact factor: 2.374

5.  A novel volume-reduced CT colonography regimen using hypertonic laxative (polyethylene glycol with ascorbic acid): randomized controlled trial.

Authors:  Kenichi Utano; Daisuke Takayanagi; Koichi Nagata; Masato Aizawa; Shungo Endo; Tetsutaro Nemoto; Daiki Nemoto; Noriyuki Isohata; Alan Kawarai Lefor; Kazutomo Togashi
Journal:  Eur Radiol       Date:  2019-03-22       Impact factor: 5.315

6.  Development of nanoparticle-based magnetic resonance colonography.

Authors:  Jihong Sun; Weiliang Zheng; Hui Zhang; Tao Wu; Hong Yuan; Xiaoming Yang; Shizheng Zhang
Journal:  Magn Reson Med       Date:  2010-11-03       Impact factor: 4.668

7.  Iohexol versus diatrizoate for fecal/fluid tagging during CT colonography performed with cathartic preparation: comparison of examination quality.

Authors:  Bohyun Kim; Seong Ho Park; Gil-Sun Hong; Ju Hee Lee; Jong Seok Lee; Hyun Jin Kim; Ah Young Kim; Hyun Kwon Ha
Journal:  Eur Radiol       Date:  2015-01-11       Impact factor: 5.315

8.  Pilot study on efficacy of reduced cathartic bowel preparation with polyethylene glycol and bisacodyl.

Authors:  Zhi-Yuan Chen; He-Song Shen; Ming-Yue Luo; Chai-Jie Duan; Wen-Li Cai; Hong-Bing Lu; Guo-Peng Zhang; Yang Liu; Jerome Z Liang
Journal:  World J Gastroenterol       Date:  2013-01-28       Impact factor: 5.742

Review 9.  Computed tomography colonography in 2014: an update on technique and indications.

Authors:  Andrea Laghi
Journal:  World J Gastroenterol       Date:  2014-12-07       Impact factor: 5.742

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.