Transcatheter closure of multi-hole perimembranous VSD with aneurysm: 3-year follow-up study.

Hong Wu1, Yongwen Qin, Xianxian Zhao, Jianqiang Hu, Xing Zheng, Ersong Wang, Weiping Li, Yanyan Wang, Bo Liu, Jing Liu, Shengqiang Wang.   

Abstract

The majority of ventricular septal defects (VSDs) are perimembranous, accounting for 75-80% of all VSDs. The objective of this study was to investigate occluder selection and transcatheter closure technique for multi-hole perimembranous VSD with aneurysm, and to evaluate clinical efficacy and safety. Patients with multi-hole VSDs and aneurysm (n = 64) were selected for the procedure using transthoracic echocardiography. Double-disc symmetrical, small-waist double-disc asymmetrical and zero eccentricity occluders were selected based on left ventricular angiography. The closure was successful in 63 of 64 patients (98%). The double-disc symmetrical occluder was used in 16 cases, the small-waist double-disc asymmetrical occluder in 42 cases, and the zero eccentricity occluder in 8 cases (2 occluder types were used in 2 cases). Fifteen minutes after the procedure, 52 cases had no residual shunt and 12 had a trace amount of residual shunt. The residual shunt disappeared in five cases 5-7 days post procedure, with a trace amount of shunt remaining in seven cases. Transient conduction abnormalities related to the procedure occurred in six patients; however, none required permanent pacemaker implantation. At the 1-month, 6-month, 1-year, 2-year, and 3-year follow-up visits, echocardiography indicated that the position of the occluders was fixed, and there were no complications including residual shunt, newly developed atrioventricular block, thromboembolism, or bacterial endocarditis. The study results indicate that left ventricular angiography is useful in selecting the most appropriate device for transcatheter closure of multi-hole perimembranous VSD with aneurysm. The transcatheter closure procedure is safe and effective with little residual shunt and no major complications for up to 3 years of follow-up.

Entities:  

Mesh:

Year:  2009        PMID: 19590919     DOI: 10.1007/s00392-009-0044-y

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  13 in total

Review 1.  Morphology of perimembranous ventricular septal defects: implications for transcatheter device closure.

Authors:  Siew Yen Ho; Karen P McCarthy; Micheal L Rigby
Journal:  J Interv Cardiol       Date:  2004-04       Impact factor: 2.279

2.  Percutaneous closure of perimembranous ventricular septal defects with the eccentric Amplatzer device: multicenter follow-up study.

Authors:  J Masura; W Gao; P Gavora; K Sun; A Q Zhou; S Jiang; L Ting-Liang; Y Wang
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

3.  Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: immediate and midterm results of an international registry.

Authors:  Ralf Holzer; Jo de Giovanni; Kevin P Walsh; Andrew Tometzki; Th Goh; Fakhri Hakim; Carlos Zabal; Jose Suarez de Lezo; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2006-10       Impact factor: 2.692

4.  Is complete heart block after surgical closure of ventricular septum defects still an issue?

Authors:  Henrik Ø Andersen; Marc R de Leval; Victor T Tsang; Martin J Elliott; Robert H Anderson; Andrew C Cook
Journal:  Ann Thorac Surg       Date:  2006-09       Impact factor: 4.330

5.  Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: initial clinical experience.

Authors:  Ziyad M Hijazi; Fakhri Hakim; A Abu Haweleh; Awni Madani; Walid Tarawna; Aktham Hiari; Qi-Ling Cao
Journal:  Catheter Cardiovasc Interv       Date:  2002-08       Impact factor: 2.692

6.  Initial experience with the Amplatzer membranous septal occluder in adults.

Authors:  Rafael Hirsch; Avraham Lorber; Yaron Shapira; David Brosh; Asaad Khoury; John L Bass; Ran Kornowski; Alexander Battler
Journal:  Acute Card Care       Date:  2007

7.  Initial human experience with the Amplatzer perimembranous ventricular septal occluder device.

Authors:  John L Bass; G S Kalra; Ramesh Arora; Jozef Masura; Pavlo Gavora; Basil D Thanopoulos; William Torres; Horst Sievert; Mario Carminati; Gunther Fischer; Peter Ewert
Journal:  Catheter Cardiovasc Interv       Date:  2003-02       Impact factor: 2.692

8.  Transcatheter closure of perimembranous ventricular septal defect using a modified double-disk occluder.

Authors:  Yongwen Qin; Jinming Chen; Xianxian Zhao; Dening Liao; Ruibin Mu; Shengqiang Wang; Hong Wu; Haoxue Guo
Journal:  Am J Cardiol       Date:  2008-04-09       Impact factor: 2.778

9.  Transcatheter closure of congenital ventricular septal defects: results of the European Registry.

Authors:  Mario Carminati; Gianfranco Butera; Massimo Chessa; Joseph De Giovanni; Gunter Fisher; Marc Gewillig; Mathias Peuster; Jean Francois Piechaud; Giuseppe Santoro; Horst Sievert; Isabella Spadoni; Kevin Walsh
Journal:  Eur Heart J       Date:  2007-08-07       Impact factor: 29.983

10.  Transcatheter closure of perimembranous ventricular septal defect with amplatzer membranous occluder.

Authors:  S R Anil; Raghavan Sreekanth; Sanjay Bhalerao; R Nagarajan; Rohit Agarwal; N B Girish
Journal:  Indian Heart J       Date:  2005 Nov-Dec
View more
  7 in total

1.  Ruptured pulmonary artery caused by isolated pulmonary valve endocarditis: case report.

Authors:  Dominik Joskowiak; U Kappert; K Matschke; S M Tugtekin
Journal:  Clin Res Cardiol       Date:  2010-03-21       Impact factor: 5.460

2.  Arrhythmias after transcatheter closure of perimembranous ventricular septal defects with a modified double-disk occluder: early and long-term results.

Authors:  Pan Li; Xian-xian Zhao; Xing Zheng; Yong-wen Qin
Journal:  Heart Vessels       Date:  2011-06-04       Impact factor: 2.037

3.  Transcatheter closure of multiple perimembranous ventricular septal defects with septal aneurysm using two overlapping Amplatzer Duct Occluders II.

Authors:  Vimalarani Devendran; Nageswara Rao Koneti; Vimala Jesudian
Journal:  Pediatr Cardiol       Date:  2012-09-18       Impact factor: 1.655

4.  Minimally-invasive-perventricular-device-occlusion versus surgical-closure for treating perimembranous-ventricular-septal-defect: 3-year outcomes of a multicenter randomized clinical trial.

Authors:  Wenxin Lu; Fengwen Zhang; Taibing Fan; Tianli Zhao; Yu Han; Xiaopeng Hu; Qi Li; Hao Shi; Xiangbin Pan
Journal:  J Thorac Dis       Date:  2021-04       Impact factor: 2.895

5.  Transcatheter Closure of Multiple Membranous Ventricular Septal Defects with Giant Aneurysms Using Double Occluders in Four Patients.

Authors:  Li-Jian Zhao; Bo Han; Jian-Jun Zhang; Ying-Chun Yi; Dian-Dong Jiang; Jian-Li Lyu; Chun-Yan Guo
Journal:  Chin Med J (Engl)       Date:  2017-01-05       Impact factor: 2.628

6.  Transcatheter closure of multi-hole perimembranous ventricular septal defect with aneurysm using two occluders.

Authors:  Yi-Yuan Huang; Zhen-Fei Fang; Jian-Jun Tang; Liang Tang; Xin-Qun Hu; Sheng-Hua Zhou
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-03-10       Impact factor: 1.426

7.  A new coated nitinol occluder for transcatheter closure of ventricular septal defects in a canine model.

Authors:  Yong Zhou; Feng Chen; Xinmiao Huang; Xianxian Zhao; Hong Wu; Yuan Bai; Yongwen Qin
Journal:  Biomed Res Int       Date:  2013-08-27       Impact factor: 3.411

  7 in total