Literature DB >> 22987109

Transcatheter closure of multiple perimembranous ventricular septal defects with septal aneurysm using two overlapping Amplatzer Duct Occluders II.

Vimalarani Devendran1, Nageswara Rao Koneti, Vimala Jesudian.   

Abstract

Ventricular septal defect (VSD) is a common congenital heart defect in children. Perimembranous VSD (Pm VSD), a defect involving the membranous septum and the adjacent portion of the muscular septum, accounts for about 70 % of cases. Transcatheter closure of Pm VSDs using the Amplatzer Pm VSD device, although successful in many patients, has been associated with major adverse events. Complete heart block, thromboembolism, and new-onset valvular regurgitations in patients undergoing VSD closure using the Pm VSD occluder have been reported [3]. Recently, a new retrograde approach for transcatheter closure of Pm VSDs using the Amplatzer Duct Occluder II (ADO II) has been described with a 90 % success rate [1]. This report describes a child who had multiple Pm VSDs with septal aneurysm undergoing successful transcatheter closure using two ADO II occluders with relative ease.

Entities:  

Mesh:

Year:  2012        PMID: 22987109     DOI: 10.1007/s00246-012-0509-z

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  4 in total

1.  Transcatheter retrograde closure of perimembranous ventricular septal defects in children with the Amplatzer duct occluder II device.

Authors:  Nageswara Rao Koneti; Narayanswami Sreeram; Raghava Raju Penumatsa; Srinivas K Arramraj; Vadlamudi Karunakar; Uwe Trieschmann
Journal:  J Am Coll Cardiol       Date:  2012-11-07       Impact factor: 24.094

2.  Transcatheter closure of multiple muscular ventricular septal defects using Gianturco coils.

Authors:  H A Latiff; M Alwi; G Kandhavel; H Samion; R Zambahari
Journal:  Ann Thorac Surg       Date:  1999-10       Impact factor: 4.330

3.  Transcatheter closure of multi-hole perimembranous VSD with aneurysm: 3-year follow-up study.

Authors:  Hong Wu; Yongwen Qin; Xianxian Zhao; Jianqiang Hu; Xing Zheng; Ersong Wang; Weiping Li; Yanyan Wang; Bo Liu; Jing Liu; Shengqiang Wang
Journal:  Clin Res Cardiol       Date:  2009-07-10       Impact factor: 5.460

4.  Transcatheter device closure of perimembranous ventricular septal defects: mid-term outcomes.

Authors:  Jian Yang; Lifang Yang; Yi Wan; Jian Zuo; Jun Zhang; Wensheng Chen; Jun Li; Lijun Sun; Shiqiang Yu; Jincheng Liu; Tao Chen; Weixun Duan; Lize Xiong; Dinghua Yi
Journal:  Eur Heart J       Date:  2010-08-27       Impact factor: 29.983

  4 in total
  3 in total

1.  Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus.

Authors:  Arkadiusz Wierzyk; Małgorzata Szkutnik; Roland Fiszer; Paweł Banaszak; Szymon Pawlak; Jacek Białkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2014-03-23       Impact factor: 1.426

2.  Transcatheter Closure of Multiple Membranous Ventricular Septal Defects with Giant Aneurysms Using Double Occluders in Four Patients.

Authors:  Li-Jian Zhao; Bo Han; Jian-Jun Zhang; Ying-Chun Yi; Dian-Dong Jiang; Jian-Li Lyu; Chun-Yan Guo
Journal:  Chin Med J (Engl)       Date:  2017-01-05       Impact factor: 2.628

3.  Transcatheter closure of multi-hole perimembranous ventricular septal defect with aneurysm using two occluders.

Authors:  Yi-Yuan Huang; Zhen-Fei Fang; Jian-Jun Tang; Liang Tang; Xin-Qun Hu; Sheng-Hua Zhou
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-03-10       Impact factor: 1.426

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.