Literature DB >> 19585599

Bolus-tracking MRI with a simultaneous T1- and T2*-measurement.

S Sourbron1, M Heilmann, A Biffar, C Walczak, J Vautier, A Volk, M Peller.   

Abstract

The aim of this study was to propose and evaluate a methodology to analyze simultaneously acquired T2*-weighted dynamic susceptibility contrast (DSC) MRI and T(1)-weighted dynamic contrast enhanced (DCE) MRI data. Two generalized models of T2*-relaxation are proposed to account for tracer leakage, and a two-compartment exchange model is used to separate tracer in intra- and extravascular spaces. The methods are evaluated using data extracted from ROIs in three mice with subcutaneously implanted human colorectal tumors. Comparing plasma flow values obtained from DCE-MRI and DSC-MRI data defines a practical experimental paradigm to measure T2*-relaxivities, and reveals a factor of 15 between values in tissue and blood. Comparing mean transit time values obtained from DCE-MRI and DSC-MRI without leakage correction, indicates a significant reduction of susceptibility weighting in DSC-MRI during tracer leakage. A one-parameter gradient correction model provides a good approximation for this susceptibility loss, but redundancy of the parameter limits the practical potential of this model for DSC-MRI. Susceptibility loss is modeled more accurately with a variable T2*-relaxivity, which allows to extract new parameters that cannot be derived from DSC-MRI or DCE-MRI alone. They reflect the cellular and vessel geometry, and thus may lead to a more complete characterization of tissue structure.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19585599     DOI: 10.1002/mrm.22042

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

Review 1.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

2.  Comparison of dual-echo DSC-MRI- and DCE-MRI-derived contrast agent kinetic parameters.

Authors:  C Chad Quarles; John C Gore; Lei Xu; Thomas E Yankeelov
Journal:  Magn Reson Imaging       Date:  2012-05-21       Impact factor: 2.546

3.  Differentiation between glioblastoma and primary CNS lymphoma: application of DCE-MRI parameters based on arterial input function obtained from DSC-MRI.

Authors:  Koung Mi Kang; Seung Hong Choi; Park Chul-Kee; Tae Min Kim; Sung-Hye Park; Joo Ho Lee; Soon-Tae Lee; Inpyeong Hwang; Roh-Eul Yoo; Tae Jin Yun; Ji-Hoon Kim; Chul-Ho Sohn
Journal:  Eur Radiol       Date:  2021-05-18       Impact factor: 5.315

4.  Evaluation of single bolus, dual-echo dynamic susceptibility contrast MRI protocols in brain tumor patients.

Authors:  Ashley M Stokes; Maurizio Bergamino; Lea Alhilali; Leland S Hu; John P Karis; Leslie C Baxter; Laura C Bell; C Chad Quarles
Journal:  J Cereb Blood Flow Metab       Date:  2021-08-20       Impact factor: 6.960

Review 5.  Magnetic Resonance Imaging of Blood-Brain Barrier permeability in Dementia.

Authors:  Audrey Chagnot; Samuel R Barnes; Axel Montagne
Journal:  Neuroscience       Date:  2021-08-13       Impact factor: 3.708

6.  Validation of a T1 and T2* leakage correction method based on multiecho dynamic susceptibility contrast MRI using MION as a reference standard.

Authors:  Ashley M Stokes; Natenael Semmineh; C Chad Quarles
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

7.  Magnetic Resonance Imaging Estimation of Longitudinal Relaxation Rate Change (ΔR1) in Dual Gradient Echo Sequences Using an Adaptive Model.

Authors:  H Bagher-Ebadian; S P Nejad-Davarani; M M Ali; S Brown; M Makki; Q Jiang; D C Noll; J R Ewing
Journal:  Proc Int Jt Conf Neural Netw       Date:  2011

8.  Dynamic contrast-enhanced quantitative susceptibility mapping with ultrashort echo time MRI for evaluating renal function.

Authors:  Luke Xie; Anita T Layton; Nian Wang; Peder E Z Larson; Jeff L Zhang; Vivian S Lee; Chunlei Liu; G Allan Johnson
Journal:  Am J Physiol Renal Physiol       Date:  2015-10-07

9.  Assessing tumor cytoarchitecture using multiecho DSC-MRI derived measures of the transverse relaxivity at tracer equilibrium (TRATE).

Authors:  Natenael B Semmineh; Junzhong Xu; Jack T Skinner; Jingping Xie; Hua Li; Gregory Ayers; C Chad Quarles
Journal:  Magn Reson Med       Date:  2014-09-16       Impact factor: 4.668

10.  A simulation tool for dynamic contrast enhanced MRI.

Authors:  Nicolas Adrien Pannetier; Clément Stéphan Debacker; Franck Mauconduit; Thomas Christen; Emmanuel Luc Barbier
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.