Literature DB >> 19581311

The intravertebral cleft in benign vertebral compression fracture: the diagnostic performance of non-enhanced MRI and fat-suppressed contrast-enhanced MRI.

C-W Ryu1, H Han, Y-M Lee, M-K Lim.   

Abstract

We compared the diagnostic performance of non-enhanced MRI and fat-suppressed contrast-enhanced MRI (CEMRI) in diagnosing intravertebral clefts in benign vertebral compression fractures (VCFs). We retrospectively reviewed 99 consecutive patients who had undergone percutaneous vertebroplasty for VCFs. A cleft was defined as a signal void or hyperintense area on non-enhanced MRI (T(1) and T(2) weighted imaging) or as a hypointense area within a diffusely enhanced vertebra on CEMRI. A cleft was confirmed as a solid opacification on post-procedural radiographs. The interobserver reliability and MRI diagnostic performance were evaluated. The interobserver reliability of non-enhanced MRI was substantial (k _ 0.698) and the interobserver reliability of CEMRI was almost perfect (k _ 0.836). Post-procedural radiographs showed solid cleft opacification in 32 out of the 99 cases. The sensitivity and specificity of non-enhanced MRI were 0.72 and 0.82 (observer 1) and 0.63 and 0.87 (observer 2), respectively. The sensitivity and specificity of CEMRI were 0.94 and 0.63 (observer 1) and 0.85 and 0.60 (observer 2), respectively. The sensitivity of CEMRI was significantly higher than that of non-enhanced MRI, and the specificity of non-enhanced MRI was higher than that of CEMRI. CEMRI was highly reliable and sensitive, and non-enhanced MRI was specific for intravertebral clefts. Therefore, spine MRIs, including CEMRI, could provide useful information about intravertebral clefts before percutaneous vertebroplasty.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19581311      PMCID: PMC3473379          DOI: 10.1259/bjr/57527063

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  23 in total

1.  Percutaneous vertebroplasty: complication avoidance and technique optimization.

Authors:  John M Mathis
Journal:  AJNR Am J Neuroradiol       Date:  2003-09       Impact factor: 3.825

2.  Intravertebral vacuum cleft: changes in content after supine positioning.

Authors:  J Malghem; B Maldague; M A Labaisse; G Dooms; T Duprez; J P Devogelaer; B Vande Berg
Journal:  Radiology       Date:  1993-05       Impact factor: 11.105

3.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

4.  Spinal vacuum phenomena: anatomical study and review.

Authors:  D Resnick; G Niwayama; J Guerra; V Vint; J Usselman
Journal:  Radiology       Date:  1981-05       Impact factor: 11.105

5.  Percutaneous vertebroplasty: treatment of painful vertebral compression fractures with intraosseous vacuum phenomena.

Authors:  Wilfred C G Peh; Michael S Gelbart; Louis A Gilula; Dallas D Peck
Journal:  AJR Am J Roentgenol       Date:  2003-05       Impact factor: 3.959

Review 6.  Idiopathic avascular necrosis of a vertebral body. Case report and literature review.

Authors:  L H Chou; R Q Knight
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

7.  Acute vertebral collapse due to osteoporosis or malignancy: appearance on unenhanced and gadolinium-enhanced MR images.

Authors:  C A Cuénod; J D Laredo; S Chevret; B Hamze; J F Naouri; X Chapaux; J M Bondeville; J M Tubiana
Journal:  Radiology       Date:  1996-05       Impact factor: 11.105

8.  Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body.

Authors:  Edward P Lin; Sven Ekholm; Akio Hiwatashi; Per-Lennart Westesson
Journal:  AJNR Am J Neuroradiol       Date:  2004-02       Impact factor: 3.825

9.  Vertebral pseudarthrosis in the osteoporotic spine.

Authors:  K Hasegawa; T Homma; S Uchiyama; H Takahashi
Journal:  Spine (Phila Pa 1976)       Date:  1998-10-15       Impact factor: 3.468

10.  Vertebral compression fractures: pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty retrospective report of 245 cases.

Authors:  Avery J Evans; Mary E Jensen; Kevin E Kip; Andrew J DeNardo; Gregory J Lawler; Geoffrey A Negin; Kent B Remley; Selene M Boutin; Steven A Dunnagan
Journal:  Radiology       Date:  2003-02       Impact factor: 11.105

View more
  11 in total

1.  Therapeutic effects of PKP on chronic painful osteoporotic vertebral compression fractures with or without intravertebral cleft.

Authors:  Debo Zou; Kaining Zhang; Yanjun Ren
Journal:  Int J Clin Exp Med       Date:  2015-09-15

2.  Development and Internal Validation of Supervised Machine Learning Algorithm for Predicting the Risk of Recollapse Following Minimally Invasive Kyphoplasty in Osteoporotic Vertebral Compression Fractures.

Authors:  Sheng-Tao Dong; Jieyang Zhu; Hua Yang; Guangyi Huang; Chenning Zhao; Bo Yuan
Journal:  Front Public Health       Date:  2022-05-02

3.  Time course of osteoporotic vertebral fractures by magnetic resonance imaging using a simple classification: a multicenter prospective cohort study.

Authors:  S Takahashi; M Hoshino; K Takayama; K Iseki; R Sasaoka; T Tsujio; H Yasuda; T Sasaki; F Kanematsu; H Kono; H Toyoda; H Nakamura
Journal:  Osteoporos Int       Date:  2016-08-30       Impact factor: 4.507

4.  Predictors of kyphotic deformity in osteoporotic vertebral compression fractures: a radiological study.

Authors:  Sanganagouda Patil; Abhay M Nene
Journal:  Eur Spine J       Date:  2014-07-11       Impact factor: 3.134

5.  Percutaneous balloon kyphoplasty of osteoporotic vertebral compression fractures with intravertebral cleft.

Authors:  Bao Chen; Shunwu Fan; Fengdong Zhao
Journal:  Indian J Orthop       Date:  2014-01       Impact factor: 1.251

6.  Early Bone Marrow Edema Pattern of the Osteoporotic Vertebral Compression Fracture : Can Be Predictor of Vertebral Deformity Types and Prognosis?

Authors:  Sung Eun Ahn; Kyung Nam Ryu; Ji Seon Park; Wook Jin; So Young Park; Sung Bum Kim
Journal:  J Korean Neurosurg Soc       Date:  2016-02-29

Review 7.  Progression of Vertebral Compression Fractures After Previous Vertebral Augmentation: Technical Reasons for Recurrent Fractures in a Previously Treated Vertebra.

Authors:  Robert E Jacobson; Ovidiu Palea; Michelle Granville
Journal:  Cureus       Date:  2017-10-16

8.  Treating osteoporotic vertebral compression fractures with intraosseous vacuum phenomena using high-viscosity bone cement via bilateral percutaneous vertebroplasty.

Authors:  Dan Guo; Jun Cai; Shengfei Zhang; Liang Zhang; Xinmin Feng
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

9.  What Effects Does Necrotic Area of Contrast-Enhanced MRI in Osteoporotic Vertebral Fracture Have on Further Compression and Clinical Outcome?

Authors:  Ja Myoung Lee; Young Seok Lee; Young Baeg Kim; Seung Won Park; Dong Ho Kang; Shin Heon Lee
Journal:  J Korean Neurosurg Soc       Date:  2017-03-01

10.  Effect of an intensive conservative therapy with daily teriparatide administration and rehabilitation for osteoporotic delayed vertebral collapse and paralysis.

Authors:  Norimitsu Wakao; Mikinobu Takeuchi; Daniel K Riew; Atsuhiko Hirasawa; Shiro Imagama; Katsuhisa Kawanami; Toshihiro Matsuo; Kenta Murotani; Masataka Deie
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.