BACKGROUND: Cardiac CT angiography (CCTA) has become a frequently used diagnostic tool in clinical practice, but concern remains about the radiation exposure. Because of the second x-ray acquisition system, dual-source CT systems might allow for high-pitch CT data acquisition and thus for examination of the whole heart during a single heart beat, with the potential for radiation dose reduction. OBJECTIVE: We assessed the feasibility of a high-pitch scan mode with a dual-source CT system. METHODS: High-pitch modes were used in patients undergoing CCTA with a dual-source CT system. Diagnostic image quality for cardiac structures and coronary arteries was assessed. Radiation dose was estimated from the scanner-generated dose-length product (DLP). RESULTS: CCTA was performed in 14 patients during a single heart beat applying a pitch value of 3.4. Mean heart rate during examination was 56.4+/-8.1 beats/min. Diagnostic image quality for the assessment of larger cardiac structures was obtained in all patients, whereas diagnostic image quality could be achieved in 82% of all coronary segments. With a mean DLP of 145+/-47 mGy x cm, the resulting estimated radiation dose was 2.0+/-0.7 mSv. CONCLUSIONS: This proof-of-concept study shows the ability of dual-source CT scanners to scan the whole heart during one single heart beat at low radiation dose.
BACKGROUND: Cardiac CT angiography (CCTA) has become a frequently used diagnostic tool in clinical practice, but concern remains about the radiation exposure. Because of the second x-ray acquisition system, dual-source CT systems might allow for high-pitch CT data acquisition and thus for examination of the whole heart during a single heart beat, with the potential for radiation dose reduction. OBJECTIVE: We assessed the feasibility of a high-pitch scan mode with a dual-source CT system. METHODS: High-pitch modes were used in patients undergoing CCTA with a dual-source CT system. Diagnostic image quality for cardiac structures and coronary arteries was assessed. Radiation dose was estimated from the scanner-generated dose-length product (DLP). RESULTS:CCTA was performed in 14 patients during a single heart beat applying a pitch value of 3.4. Mean heart rate during examination was 56.4+/-8.1 beats/min. Diagnostic image quality for the assessment of larger cardiac structures was obtained in all patients, whereas diagnostic image quality could be achieved in 82% of all coronary segments. With a mean DLP of 145+/-47 mGy x cm, the resulting estimated radiation dose was 2.0+/-0.7 mSv. CONCLUSIONS: This proof-of-concept study shows the ability of dual-source CT scanners to scan the whole heart during one single heart beat at low radiation dose.
Authors: Annika Schuhbäck; Mohamed Marwan; Sören Gauss; Gerd Muschiol; Dieter Ropers; Christian Schneider; Michael Lell; Johannes Rixe; Christian Hamm; Werner G Daniel; Stephan Achenbach Journal: Eur Radiol Date: 2012-03-27 Impact factor: 5.315
Authors: E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri Journal: Radiol Med Date: 2010-06-23 Impact factor: 3.469
Authors: E Maffei; S Seitun; C Martini; A Aldrovandi; G Cervellin; C Tedeschi; A Guaricci; G Messalli; O Catalano; F Cademartiri Journal: Radiol Med Date: 2011-03-07 Impact factor: 3.469
Authors: Gorka Bastarrika; Jordi Broncano; María Arraiza; Pedro M Azcárate; Isabel Simon-Yarza; Beltrán G Levy Praschker; Jesús C Pueyo; José L Zubieta; Gregorio Rabago Journal: Eur Radiol Date: 2011-04-12 Impact factor: 5.315
Authors: Jelena R Ghadri; Silke M Küest; Robert Goetti; Michael Fiechter; Aju P Pazhenkottil; Rene N Nkoulou; Felix P Kuhn; Carsten Pietsch; Patrick von Schulthess; Oliver Gaemperli; Christian Templin; Philipp A Kaufmann Journal: Int J Cardiovasc Imaging Date: 2011-07-10 Impact factor: 2.357
Authors: Bernhard Bischoff; Simon Deseive; Martin Rampp; Andrei Todica; Marc Wermke; Stefan Martinoff; Steffen Massberg; Maximilian F Reiser; Hans-Christoph Becker; Jörg Hausleiter Journal: Int J Cardiovasc Imaging Date: 2016-11-15 Impact factor: 2.357
Authors: Filippo Cademartiri; Erica Maffei; Alessandro Palumbo; Sara Seitun; Chiara Martini; Carlo Tedeschi; Ludovico La Grutta; Massimo Midiri; Annick C Weustink; Nico R Mollet; Gabriel P Krestin Journal: Eur Radiol Date: 2009-09-16 Impact factor: 5.315