Feasibility of saccadic vector optokinetic perimetry: a method of automated static perimetry for children using eye tracking.

Ian C Murray1, Brian W Fleck, Harry M Brash, Mary E Macrae, Lai L Tan, Robert A Minns.   

Abstract

PURPOSE: To determine the feasibility of a new technique for suprathreshold automated static perimetry in children.
DESIGN: Evaluation of diagnostic test or technology. PARTICIPANTS: The study included 29 subjects comprising 4 groups: 12 adults with normal fields, 4 children aged less than 10 years with normal fields, 8 adults with visual field defect, and 5 children aged less than 10 years with suspected visual field defects.
METHODS: The system comprises a personal computer, display, and eye tracker to monitor gaze position when stimuli are presented in the visual field. The natural saccadic eye movement to fixate on the stimuli, if seen, can be detected and measured to produce a visual field plot. Subjects performed 3 eye-tracking tests, unless unable to do so for any reason: a 40-point binocular test and two 41-point tests for each eye. The tests were based on the Humphrey Field Analyzer (HFA) Central-40 point screening test with a stimulus size of Goldmann III and intensity of 14 decibels (dB). Adults also performed the equivalent Humphrey screening test in each eye for comparison. MAIN OUTCOME MEASURES: Comparison of visual field plot results between the eye-tracking tests and HFA tests in adults. Correlation between the eye-tracking tests and the clinical assessment in the children with suspected visual field defects.
RESULTS: In the eyes of all normal adult and child subjects performing the eye-tracking test, the percentage of points in agreement with a healthy visual field was 99.2% and 99.1%, respectively. The percentage of points agreeing with the HFA's screening test in the adult eyes with visual field defects was 89.8%. Visual field defects were also correctly identified by the eye-tracking system in the eyes of children with suspected visual field defects.
CONCLUSIONS: The results demonstrate that suprathreshold automated static perimetry using eye tracking is a promising method of perimetry for use with children.

Entities:  

Mesh:

Year:  2009        PMID: 19560207     DOI: 10.1016/j.ophtha.2009.03.015

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  22 in total

Review 1.  Visual function in children with primary brain tumors.

Authors:  Jason H Peragallo
Journal:  Curr Opin Neurol       Date:  2019-02       Impact factor: 5.710

2.  Perimetric evaluation of saccadic latency, saccadic accuracy, and visual threshold for peripheral visual stimuli in young compared with older adults.

Authors:  David E Warren; Matthew J Thurtell; Joy N Carroll; Michael Wall
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-08-27       Impact factor: 4.799

3.  Comparison of Quality and Output of Different Optimal Perimetric Testing Approaches in Children With Glaucoma.

Authors:  Dipesh E Patel; Phillippa M Cumberland; Bronwen C Walters; Isabelle Russell-Eggitt; John Brookes; Maria Papadopoulos; Peng Tee Khaw; Ananth C Viswanathan; David Garway-Heath; Mario Cortina-Borja; Jugnoo S Rahi
Journal:  JAMA Ophthalmol       Date:  2018-02-01       Impact factor: 7.389

4.  A novel Bayesian adaptive method for mapping the visual field.

Authors:  Pengjing Xu; Luis Andres Lesmes; Deyue Yu; Zhong-Lin Lu
Journal:  J Vis       Date:  2019-12-02       Impact factor: 2.240

5.  Validity and Repeatability of Saccadic Response Times Across the Visual Field in Eye Movement Perimetry.

Authors:  Johan J M Pel; Michel C M van Beijsterveld; Gijs Thepass; Johannes van der Steen
Journal:  Transl Vis Sci Technol       Date:  2013-11-13       Impact factor: 3.283

6.  Development of a Pediatric Visual Field Test.

Authors:  Marco A Miranda; David B Henson; Cecilia Fenerty; Susmito Biswas; Tariq Aslam
Journal:  Transl Vis Sci Technol       Date:  2016-12-14       Impact factor: 3.283

7.  Development of a test grid using Eye Movement Perimetry for screening glaucomatous visual field defects.

Authors:  N S Kadavath Meethal; D Mazumdar; R Asokan; M Panday; J van der Steen; K A Vermeer; H G Lemij; R J George; J J M Pel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-12-28       Impact factor: 3.117

8.  Study of Optimal Perimetric Testing in Children (OPTIC): Feasibility, Reliability and Repeatability of Perimetry in Children.

Authors:  Dipesh E Patel; Phillippa M Cumberland; Bronwen C Walters; Isabelle Russell-Eggitt; Jugnoo S Rahi
Journal:  PLoS One       Date:  2015-06-19       Impact factor: 3.240

9.  Comparison of saccadic reaction time between normal and glaucoma using an eye movement perimeter.

Authors:  Deepmala Mazumdar; J J M Pel; Manish Panday; Rashima Asokan; L Vijaya; B Shantha; Ronnie George; J Van Der Steen
Journal:  Indian J Ophthalmol       Date:  2014-01       Impact factor: 1.848

10.  Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry.

Authors:  Ian C Murray; Lorraine A Cameron; Alice D McTrusty; Antonios Perperidis; Harry M Brash; Brian W Fleck; Robert A Minns
Journal:  Transl Vis Sci Technol       Date:  2016-08-31       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.