Literature DB >> 19557489

Survivorship of a low-stiffness extensively porous-coated femoral stem at 10 years.

Mark A Hartzband1, Andrew H Glassman, Victor M Goldberg, Louis R Jordan, Roy D Crowninshield, Kevin B Fricka, Louis C Jordan.   

Abstract

UNLABELLED: A novel low-stiffness extensively porous-coated total hip femoral component was designed to achieve stable skeletal fixation, structural durability, and reduced periprosthetic femoral stress shielding. In short- to intermediate-term clinical review, this implant achieved secure biologic fixation and preserved periprosthetic bone. We retrospectively reviewed all 102 prospectively followed patients (106 implants) with this implant to document the longer-term implant survivorship, clinical function, fixation quality, and periprosthetic bone preservation. Ninety-seven patients with 101 implants had current followup or were followed to patient death (range, 1-14 years; average, 10 years). Eighty-six living patients were followed for an average implant survivorship of 10 years. There were no known femoral implant removals. The average Harris hip score at 10-year followup was 98. Radiographs demonstrated secure implant fixation and maintenance of periprosthetic bone. These data suggest this implant design provided long-term function characterized by extensive fixation, structural durability, and radiographic appearance of maintained periprosthetic cortical thickness and density. LEVEL OF EVIDENCE: Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19557489      PMCID: PMC2807009          DOI: 10.1007/s11999-009-0950-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  27 in total

1.  Current sterilization and packaging methods for polyethylene.

Authors:  L S Bargmann; B C Bargmann; J P Collier; B H Currier; M B Mayor
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

2.  A low stiffness composite biologically fixed prosthesis.

Authors:  A H Glassman; R D Crowninshield; R Schenck; P Herberts
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

3.  Material optimization of femoral component of total hip prosthesis using fiber reinforced polymeric composites.

Authors:  H Katoozian; D T Davy; A Arshi; U Saadati
Journal:  Med Eng Phys       Date:  2001-09       Impact factor: 2.242

4.  Clinical and histologic results related to a low-modulus composite total hip replacement stem.

Authors:  Sam Akhavan; Mary M Matthiesen; Leah Schulte; Tom Penoyar; Matthew J Kraay; Clare M Rimnac; Victor M Goldberg
Journal:  J Bone Joint Surg Am       Date:  2006-06       Impact factor: 5.284

5.  Early failure of a press-fit carbon fiber hip prosthesis with a smooth surface.

Authors:  Frank Adam; Dietrich Stephan Hammer; Steffen Pfautsch; Kord Westermann
Journal:  J Arthroplasty       Date:  2002-02       Impact factor: 4.757

6.  Poor results from the isoelastic total hip replacement: 14-17-year follow-up of 149 cementless prostheses.

Authors:  Rihard Trebse; Ingrid Milosev; Simon Kovac; Martin Mikek; Venceslav Pisot
Journal:  Acta Orthop       Date:  2005-04       Impact factor: 3.717

7.  Polyethylene sterilization and production affects wear in total hip arthroplasties.

Authors:  Philip M Faris; Merrill A Ritter; Andrew L Pierce; Kenneth E Davis; Gregory W Faris
Journal:  Clin Orthop Relat Res       Date:  2006-12       Impact factor: 4.176

8.  Influence of porous coating level on proximal femoral remodeling. A postmortem analysis.

Authors:  J P McAuley; C J Sychterz; C A Engh
Journal:  Clin Orthop Relat Res       Date:  2000-02       Impact factor: 4.176

9.  Evaluation of a femoral stem with reduced stiffness. A randomized study with use of radiostereometry and bone densitometry.

Authors:  Johan Kärrholm; Christian Anderberg; Finnur Snorrason; Jonas Thanner; Norvald Langeland; Henrik Malchau; Peter Herberts
Journal:  J Bone Joint Surg Am       Date:  2002-09       Impact factor: 5.284

10.  Progressive failure analysis of laminated composite femoral prostheses for total hip arthroplasty.

Authors:  Chaodi Li; Christopher Granger; H Del Schutte; Sherrill B Biggers; John M Kennedy; Robert A Latour
Journal:  Biomaterials       Date:  2002-11       Impact factor: 12.479

View more
  7 in total

1.  Bone remodeling after a mean of 10 years in diaphyseal cortical defects repaired with femoral revision using bypass fixation of extensively porous-coated stems with high stiffness.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-01-04

2.  Effect of implant composition on periprosthetic bone mineral density after total hip arthroplasty.

Authors:  Akira Morita; Naomi Kobayashi; Hyonmin Choe; Taro Tezuka; Toshihiro Misumi; Yutaka Inaba
Journal:  Arch Orthop Trauma Surg       Date:  2022-07-20       Impact factor: 2.928

3.  Radiological Evaluation of the Relationship Between Cortical Hypertrophy and Stress Shielding After Total Hip Arthroplasty Using a Cementless Stem.

Authors:  Makoto Kanto; Shigeo Fukunishi; Tomokazu Fukui; Shoji Nishio; Yuki Fujihara; Shohei Okahisa; Yu Takeda; Shinichi Yoshiya; Toshiya Tachibana
Journal:  Arthroplast Today       Date:  2020-11-03

4.  Maintenance of a bone collagen phenotype by osteoblast-like cells in 3D periodic porous titanium (Ti-6Al-4 V) structures fabricated by selective electron beam melting.

Authors:  Nikolas W Hrabe; Peter Heinl; Rajendra K Bordia; Carolin Körner; Russell J Fernandes
Journal:  Connect Tissue Res       Date:  2013-09-30       Impact factor: 3.417

5.  Ultrashort versus Conventional Anatomic Cementless Femoral Stems in the Same Patients Younger Than 55 Years.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2016-06-03       Impact factor: 4.176

Review 6.  Lower limb joint repair and replacement: an overview.

Authors:  Rocco Aicale; Nicola Maffulli
Journal:  F1000Res       Date:  2019-12-19

Review 7.  Periprosthetic bone remodeling of short cementless femoral stems in primary total hip arthroplasty: A systematic review and meta-analysis of randomized-controlled trials.

Authors:  Shuang G Yan; Di Li; Shuai Yin; Xingyi Hua; Jian Tang; Florian Schmidutz
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.