Literature DB >> 19550001

Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols.

D R Dance1, K C Young, R E van Engen.   

Abstract

The United Kingdom, European and IAEA protocols for breast dosimetry in mammography make use of s-factors which allow for the use of different target/filter combinations. To supplement the existing protocols, a Monte Carlo computer program has been used to calculate s-factors for mammography using a tungsten target with silver filters of thicknesses 50-75 microm and for the same target filtered with 0.5 mm aluminium. The dosimetry protocols use slabs of polymethyl methacrylate (PMMA) of specified thicknesses to simulate the exposure of typical breasts. The equivalent thickness of PMMA has been calculated using a simplified approach for a wider range of x-ray spectra and for breast thicknesses of 2-11 cm. The results show that for the tungsten/silver target/filter combination, a single s-factor of 1.042 can be used with the protocols, but when the tungsten target is filtered with 0.5 mm of aluminium, it is necessary to select from a tabulation of s-factors against breast thickness. The equivalent thicknesses of PMMA for a given breast thickness show some dependence on beam quality and the values obtained differ from those presently used in the dosimetry protocols by an amount which depends upon breast thickness and half value layer (HVL). For the extreme case of an 11 cm breast and an HVL of 0.62 mm Al, the use of the protocol thickness would give rise to an error of 10%, but for breast thicknesses of 6 cm or less, the error is typically 2-3%.

Entities:  

Mesh:

Year:  2009        PMID: 19550001     DOI: 10.1088/0031-9155/54/14/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  Radiation doses received in the United Kingdom breast screening programme in 2010 to 2012.

Authors:  Kenneth C Young; Jennifer M Oduko
Journal:  Br J Radiol       Date:  2015-12-14       Impact factor: 3.039

2.  Clinical dose performance of full field digital mammography in a breast screening programme.

Authors:  J B McCullagh; P Baldelli; N Phelan
Journal:  Br J Radiol       Date:  2011-05-17       Impact factor: 3.039

3.  The potential use of ultra-low radiation dose images in digital mammography--a clinical proof-of-concept study in craniocaudal views.

Authors:  A M J Bluekens; W J H Veldkamp; K H Schuur; N Karssemeijer; M J M Broeders; G J den Heeten
Journal:  Br J Radiol       Date:  2015-01-09       Impact factor: 3.039

4.  Mean glandular dose in digital mammography: a dose calculation method comparison.

Authors:  Moayyad E Suleiman; Patrick C Brennan; Mark F McEntee
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-24

5.  A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

Authors:  Antonio Sarno; David R Dance; Ruben E van Engen; Kenneth C Young; Paolo Russo; Francesca Di Lillo; Giovanni Mettivier; Kristina Bliznakova; Baowei Fei; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2017-06-13       Impact factor: 4.071

6.  Towards standardization of x-ray beam filters in digital mammography and digital breast tomosynthesis: Monte Carlo simulations and analytical modelling.

Authors:  Suman Shrestha; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med Biol       Date:  2017-01-11       Impact factor: 3.609

7.  Low-dose, phase-contrast mammography with high signal-to-noise ratio.

Authors:  Lukas B Gromann; Dirk Bequé; Kai Scherer; Konstantin Willer; Lorenz Birnbacher; Marian Willner; Julia Herzen; Susanne Grandl; Karin Hellerhoff; Jonathan I Sperl; Franz Pfeiffer; Cristina Cozzini
Journal:  Biomed Opt Express       Date:  2016-01-07       Impact factor: 3.732

8.  Integrating mammographic breast density in glandular dose calculation.

Authors:  Moayyad E Suleiman; Patrick C Brennan; Ernest Ekpo; Peter Kench; Mark F McEntee
Journal:  Br J Radiol       Date:  2018-02-13       Impact factor: 3.039

9.  Human-Compatible Multi-Contrast Mammographic Prototype System.

Authors:  Ran Zhang; Ke Li; John W Garrett; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-07

10.  Testing a dual-modality system that combines full-field digital mammography and automated breast ultrasound.

Authors:  Christopher L Vaughan; Tania S Douglas; Qonita Said-Hartley; Roland V Baasch; James A Boonzaier; Brian C Goemans; John Harverson; Michael W Mingay; Shuaib Omar; Raphael V Smith; Nielen C Venter; Heidi S Wilson
Journal:  Clin Imaging       Date:  2015-12-03       Impact factor: 1.605

View more