Literature DB >> 19545810

Repeatability and validity of lens densitometry measured with Scheimpflug imaging.

Bradley J Kirkwood1, Peter L Hendicott, Scott A Read, Konrad Pesudovs.   

Abstract

PURPOSE: To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system.
SETTING: Eye Clinic, Queensland University of Technology, Brisbane, Australia.
METHODS: This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through a dilated pupil. Lenses were graded with the Lens Opacities Classification System III. Intraobserver and interobserver reliability of 3 observers performing 3 repeated Scheimpflug lens densitometry measurements each was assessed. Three lens densitometry metrics were evaluated: linear, for which a line was drawn through the visual axis and a mean lens densitometry value given; peak, which is the point at which lens densitometry is greatest on the densitogram; 3-dimensional (3D), in which a fixed, circular 3.0 mm area of the lens is selected and a mean lens densitometry value given. Bland and Altman analysis of repeatability for multiple measures was applied; results were reported as the repeatability coefficient and relative repeatability (RR).
RESULTS: Twenty eyes were evaluated. Repeatability was high. Overall, interobserver repeatability was marginally lower than intraobserver repeatability. The peak was the least reliable metric (RR 37.31%) and 3D, the most reliable (RR 5.88%). Intraobserver and interobserver lens densitometry values in the cataract group were slightly less repeatable than in the noncataract group.
CONCLUSION: The intraobserver and interobserver repeatability of Scheimpflug lens densitometry was high in eyes with cataract and eyes without cataract, which supports the use of automated lens density scoring using the Scheimpflug system evaluated in the study.

Entities:  

Mesh:

Year:  2009        PMID: 19545810     DOI: 10.1016/j.jcrs.2009.03.017

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  20 in total

1.  Quantitative Scheimpflug camera study of the lens density in healthy Turkish population.

Authors:  Taner Kar; Yakup Aksoy; Yıldıray Yıldırım; Abdullah Kaya; Ali Ayata; Melih Hamdi Ünal
Journal:  Int Ophthalmol       Date:  2016-02-25       Impact factor: 2.031

2.  Psychophysical impact and optical and morphological characteristics of symptomatic non-advanced cataract.

Authors:  S Charalampidou; J Nolan; J Loughman; J Stack; G Higgins; L Cassidy; S Beatty
Journal:  Eye (Lond)       Date:  2011-06-10       Impact factor: 3.775

3.  Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification.

Authors:  Süleyman Demircan; Mustafa Ataş; Emre Göktaş; Burhan Başkan
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

4.  Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.

Authors:  Fernando Faria-Correia; Bernardo Lopes; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Int Ophthalmol       Date:  2017-05-26       Impact factor: 2.031

5.  A test of lens opacity as an indicator of preclinical Alzheimer Disease.

Authors:  Ling Bei; Ying-Bo Shui; Fang Bai; Suzanne K Nelson; Gregory P Van Stavern; David C Beebe
Journal:  Exp Eye Res       Date:  2015-03-13       Impact factor: 3.467

6.  Clinical applications of Scheimpflug imaging in cataract surgery.

Authors:  Dilraj Singh Grewal; Satinder Pal Singh Grewal
Journal:  Saudi J Ophthalmol       Date:  2012-01

7.  The quantitative assessment of alterations in lens transparency after transconjunctival 27-gauge microincision vitrectomy surgery.

Authors:  K Tekin; M Inanc; K Ozdemir; K Sonmez; P Yilmazbas
Journal:  Eye (Lond)       Date:  2017-10-27       Impact factor: 3.775

8.  Assessment of cataract forming effect of diabetes in young adults by lens densitometer.

Authors:  Neslihan Bayraktar Bilen; Murat Sinan Sarıcaoğlu
Journal:  Int Ophthalmol       Date:  2020-10-28       Impact factor: 2.031

9.  Clinical characteristics and outcomes of cataract surgery in highly myopic Koreans.

Authors:  Sohee Jeon; Hyun Seung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

10.  Volumetric macro- and micro-scale assessment of crystalline lens opacities in cataract patients using long-depth-range swept source optical coherence tomography.

Authors:  Ireneusz Grulkowski; Silvestre Manzanera; Lukasz Cwiklinski; Juan Mompeán; Alberto de Castro; Jose Maria Marin; Pablo Artal
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.