Literature DB >> 19545805

Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia.

Evdoxia Terzi1, Li Wang, Thomas Kohnen.   

Abstract

PURPOSE: To determine the accuracy of the Holladay 2, Hoffer Q, SRK/T, and Haigis intraocular lens (IOL) power calculation formulas in high myopic and high hyperopic refractive lens exchange (RLE) with hydrophobic acrylic foldable IOLs.
SETTING: Department of Ophthalmology, Johann Wolfgang Goethe University, Frankfurt am Main, Germany.
METHODS: Preoperatively, axial length (AL) was measured by partial coherence interferometry with the IOLMaster. The RLE was performed by phacoemulsification with posterior chamber IOL implantation in the capsular bag. Optimization of the lens constants for each IOL type was done separately for eyes with a positive lens and eyes with a negative lens. Prediction error (predicted refraction - postoperative refraction) and mean absolute error were back-calculated for the Holladay 2, Hoffer Q, SRK/T, and Haigis formulas.
RESULTS: Sixty-three eyes (44 myopic, AL >or=26.0 mm; 19 hyperopic, AL <or=22.0 mm) were included. In myopic and hyperopic RLE, all 4 formulas had an overall good performance. In myopic RLE, the Haigis formula performed better.
CONCLUSION: In myopic and hyperopic RLE, optimization of lens constants improved the accuracy of IOL power calculation.

Entities:  

Mesh:

Year:  2009        PMID: 19545805     DOI: 10.1016/j.jcrs.2009.02.026

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  20 in total

1.  Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

Authors:  Çağatay Çağlar; Sücattin İlker Kocamış; Emre Demir; Mustafa Durmuş
Journal:  Int Ophthalmol       Date:  2016-07-08       Impact factor: 2.031

2.  Comparison of formulas and methods for high myopia patients requiring intraocular lens powers less than six diopters.

Authors:  Harry S Geggel
Journal:  Int Ophthalmol       Date:  2017-06-20       Impact factor: 2.031

3.  [Evaluation and quality assurance of refractive surgery procedures by the German Ophthalmological Society and the Professional Association of German Ophthalmologists. Status: May 2011].

Authors:  T Kohnen; T Neuhann; M Knorz
Journal:  Ophthalmologe       Date:  2011-09       Impact factor: 1.059

4.  Agreement analysis of LENSTAR with other techniques of biometry.

Authors:  S Jasvinder; T F Khang; K K S Sarinder; V P Loo; V Subrayan
Journal:  Eye (Lond)       Date:  2011-03-11       Impact factor: 3.775

5.  A study to evaluate whether CTR increases refractive unpredictability between predicted and actual IOL position.

Authors:  V K Baranwal; Santosh Kumar; Avinash Mishra; Ajay K Dutta
Journal:  Med J Armed Forces India       Date:  2012-10-31

6.  Long-term results of clear lens extraction combined with piggyback intraocular lens implantation to correct high hyperopia.

Authors:  Xia Hua; Xiao-Yong Yuan; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

7.  Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths.

Authors:  Jia-Kang Wang; Shu-Wen Chang
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

8.  Accuracy of intraocular lens power calculation in high myopia.

Authors:  Asaad A Ghanem; Hosam M El-Sayed
Journal:  Oman J Ophthalmol       Date:  2010-09

9.  Intraocular lens power calculation using IOLMaster and various formulas in short eyes.

Authors:  Young Rae Roh; Sang Mok Lee; Young Keun Han; Mee Kum Kim; Won Ryang Wee; Jin Hak Lee
Journal:  Korean J Ophthalmol       Date:  2011-05-24

10.  Accuracy of intraocular lens power calculation formulas in primary angle closure glaucoma.

Authors:  Jongsoo Joo; Woong-Ju Whang; Tae-Hoon Oh; Kyu-Dong Kang; Hyun-Seung Kim; Jung-Il Moon
Journal:  Korean J Ophthalmol       Date:  2011-11-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.