Literature DB >> 19536729

[Radiological placement of peripheral central venous access ports at the forearm. Technical results and long term outcome in 391 patients].

M Lenhart1, S Schätzler, C Manke, M Strotzer, J Seitz, J Gmeinwieser, M Völk, N Zorger, S Feuerbach, T Herold, C Paetzel.   

Abstract

PURPOSE: To retrospectively analyze the technical result and long term outcome of central venous arm ports placed by radiologists. MATERIALS AND
METHOD: Over a 5-year period, 399 arm ports were implanted by radiologists in 391 patients. The system consists of a low profile titanium chamber and a silicone catheter. Ports were placed at the forearm after puncture of a vein proximally to the elbow under fluoroscopic guidance. In a retrospective analysis the technical results and the long term outcome were evaluated. Complications were documented according to the standards of the society of interventional radiology.
RESULTS: In 391 patients a total of 98 633 catheter days were documented (1 - 1325 days, mean 252 days). Primary technical success was 99.25 % (396 / 399) with a 100 % secondary technical success rate. No severe procedural complications, e. g. pneumothorax or severe hemorrhage, were found. A total of 45 complications occurred (11.28 %, 0.45 / 1000 catheter days), including 8 portal pocket infections (27 - 205 days, mean 115 days). Fifteen ports were explanted because of complications. The complication rate corresponds to the data from subclavian ports and is less than the complication rates published in large surgical trials.
CONCLUSION: Implantation of central-venous arm ports by radiologists is safe and minimally invasive. No severe immediate procedural complications occur due to the peripheral implantation site. Long term complication rates are comparable to other studies of radiological or surgical port implantation at different sites. (c) Georg Thieme Verlag KG Stuttgart-New York.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19536729     DOI: 10.1055/s-0028-1109453

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  11 in total

1.  Totally implantable venous power ports of the forearm and the chest: initial clinical experience with port devices approved for high-pressure injections.

Authors:  J P Goltz; C Noack; B Petritsch; J Kirchner; D Hahn; R Kickuth
Journal:  Br J Radiol       Date:  2012-06-06       Impact factor: 3.039

2.  [Superior vena cava occlusion : Radiological placement of a central venous port system via femoral vein access].

Authors:  P Heiss; C Stroszczynski; H Gössmann
Journal:  Radiologe       Date:  2012-05       Impact factor: 0.635

3.  Femoral placement of totally implantable venous power ports as an alternative implantation site for patients with central vein occlusions.

Authors:  Jan P Goltz; Hendrik Janssen; Bernhard Petritsch; Ralph Kickuth
Journal:  Support Care Cancer       Date:  2013-09-24       Impact factor: 3.603

4.  Placement of port-a-cath through the right internal jugular vein under ultrasound guidance.

Authors:  E Capalbo; M Peli; M Lovisatti; M Cosentino; V Ticha; M Cariati; G Cornalba
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

5.  Percutaneous image-guided implantation of totally implantable venous access ports in the forearm or the chest? A patients' point of view.

Authors:  Jan Peter Goltz; Bernhard Petritsch; Johannes Kirchner; Dietbert Hahn; Ralph Kickuth
Journal:  Support Care Cancer       Date:  2012-07-25       Impact factor: 3.603

6.  [Indications, technique and complications of port implantation].

Authors:  L Haeder; J Jähne
Journal:  Chirurg       Date:  2013-07       Impact factor: 0.955

7.  Central venous port systems as an integral part of chemotherapy.

Authors:  Ulf K Teichgräber; Robert Pfitzmann; Herbert A F Hofmann
Journal:  Dtsch Arztebl Int       Date:  2011-03-04       Impact factor: 5.594

8.  Short-term and long-term outcome of radiological-guided insertion of central venous access port devices implanted at the forearm: a retrospective monocenter analysis in 1704 patients.

Authors:  Moritz Wildgruber; Sebastian Borgmeyer; Bernhard Haller; Heike Jansen; Jochen Gaa; Marion Kiechle; Reinhard Meier; Johannes Ettl; Hermann Berger
Journal:  Eur Radiol       Date:  2014-09-20       Impact factor: 5.315

Review 9.  Systematic review: malfunction of totally implantable venous access devices in cancer patients.

Authors:  Godelieve Alice Goossens; Marguerite Stas; Martine Jérôme; Philip Moons
Journal:  Support Care Cancer       Date:  2011-05-10       Impact factor: 3.603

10.  Implantation of venous access devices under local anesthesia: patients' satisfaction with oral lorazepam.

Authors:  De-Hua Chang; Sonja Hiss; Lena Herich; Ingrid Becker; Kamal Mammadov; Mareike Franke; Anastasios Mpotsaris; Robert Kleinert; Thorsten Persigehl; David Maintz; Christopher Bangard
Journal:  Patient Prefer Adherence       Date:  2015-07-07       Impact factor: 2.711

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.