Literature DB >> 16322716

Effect of the diastolic and systolic duration on valve cavitation in a pediatric pulsatile ventricular assist device.

Branka Lukic1, Conrad M Zapanta, Kimberly A Griffith, William J Weiss.   

Abstract

Minimization of cavitation is of high importance in the design of pulsatile ventricular assist devices because cavitation can cause blood and valve surface damage. Cavitation is associated with valve closure and has been previously correlated to high dP/dt, high valve closing velocity, and decreased pump filling. In this study, the effects of diastolic and systolic duration on the inlet and outlet valve cavitation were investigated. A low volume (280 ml) mock circulatory loop filled with room-temperature saline was used. A high-fidelity hydrophone was mounted into the inlet valve connector approximately 0.5 cm upstream from the inlet valve to quantify inlet valve cavitation. The inlet valve connector and hydrophone were placed symmetrically on the outlet side when measuring outlet valve cavitation. The RMS intensity of a 6-millisecond window pressure trace, bandpass filtered from 50 to 500 kHz, was used to quantify cavitation intensity. Approximately 80 beats were recorded at every test condition. High-speed video and an accelerometer were used to determine the position of the valves during closure. The cavitation intensity of the inlet valve was minimal when the onset of systole occurred at the moment when the pump just completed filling (RMS was approximately zero). The cavitation intensity increased when the onset of systole occurred before the pump was completely filled (valve partially opened), reaching a plateau of approximately 16 mm Hg when the valve was fully open. The cavitation intensity increased again when diastolic duration exceeded pump filling time by more than 30 milliseconds. The outlet valve cavitation intensity was very low (<4 mm Hg) regardless of the systolic duration, which can be attributed to the position of the hydrophone being on the opposite side of cavitation events. Although very small, the outlet cavitation intensities with respect to systolic duration show a trend similar to the inlet valve cavitation with respect to diastolic duration. Both inlet and outlet valve cavitation increased with increased peak regurgitant flow. An understanding of the relationship of the inlet and outlet valve cavitation to the diastolic and systolic duration can be used to determine the optimal operating conditions of the pulsatile pediatric pump.

Entities:  

Mesh:

Year:  2005        PMID: 16322716     DOI: 10.1097/01.mat.0000178964.45296.9b

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  7 in total

1.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

2.  Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals.

Authors:  Hwansung Lee; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

3.  Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.

Authors:  Hwansung Lee; Yoshiaki Ikeuchi; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka; Takao Yamamoto
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

4.  Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing.

Authors:  Hwansung Lee; Akihiko Homma; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

5.  The influence of operational protocol on the fluid dynamics in the 12 cc Penn state pulsatile pediatric ventricular assist device: the effect of end-diastolic delay.

Authors:  Benjamin T Cooper; Breigh N Roszelle; Tobias C Long; Steven Deutsch; Keefe B Manning
Journal:  Artif Organs       Date:  2010-04       Impact factor: 3.094

6.  Chronic in vivo testing of the Penn State infant ventricular assist device.

Authors:  William J Weiss; Elizabeth L Carney; J Brian Clark; Rebecca Peterson; Timothy K Cooper; Thomas P Nifong; Christopher A Siedlecki; Dennis Hicks; Bradley Doxtater; Branka Lukic; Eric Yeager; John Reibson; Joshua Cysyk; Gerson Rosenberg; William S Pierce
Journal:  ASAIO J       Date:  2012 Jan-Feb       Impact factor: 2.872

7.  Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

Authors:  Breigh N Roszelle; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2010-02       Impact factor: 3.934

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.