Literature DB >> 11672716

Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage.

W L Lim1, Y T Chew, T C Chew, H T Low.   

Abstract

A two-dimensional particle image tracking velocimetry (PIV) system has been used to map the velocity vector fields and Reynolds stresses in the immediate downstream vicinity of a porcine bioprosthetic heart valve at the aortic root region in vitro under pulsatile flow conditions. Measurements were performed at five different time steps of the systolic phase of the cardiac cycle. The velocity vector fields and Reynolds stress mappings at different time steps allowed us to chart a time history of the stress levels experienced by fluid particles as they move across the aortic root. This Lagrangian description of the stresses experienced by individual blood cells enabled us to estimate the propensity of shear-induced damage to platelets and red blood cells. Coupled with flow visualization techniques, the hydrodynamic consequences of introducing a porcine bioprosthetic heart valve into the aortic root was examined. Although the PIV measurements may lack the accuracy of single point measuring systems, the overall view of the flow in the aortic root region compensates for the shortcoming.

Entities:  

Mesh:

Year:  2001        PMID: 11672716     DOI: 10.1016/s0021-9290(01)00132-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  17 in total

1.  Protocol for relative hydrodynamic assessment of tri-leaflet polymer valves.

Authors:  Sharan Ramaswamy; Manuel Salinas; Rob Carrol; Karla Landaburo; Xavier Ryans; Cynthia Crespo; Ailyn Rivero; Faris Al-Mousily; Curt DeGroff; Mark Bleiweis; Hitomi Yamaguchi
Journal:  J Vis Exp       Date:  2013-10-17       Impact factor: 1.355

2.  Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.

Authors:  Hwansung Lee; Yoshiaki Ikeuchi; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka; Takao Yamamoto
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

3.  Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

Authors:  Yubing Shi; Tony Joon Hock Yeo; Yong Zhao; Ned H C Hwang
Journal:  J Biol Phys       Date:  2007-03-28       Impact factor: 1.365

4.  Blood damage through a bileaflet mechanical heart valve: a quantitative computational study using a multiscale suspension flow solver.

Authors:  B Min Yun; Cyrus K Aidun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-10       Impact factor: 2.097

5.  Effect of Arched Leaflets and Stent Profile on the Hemodynamics of Tri-Leaflet Flexible Polymeric Heart Valves.

Authors:  Atieh Yousefi; David L Bark; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-06-15       Impact factor: 3.934

6.  Design and validation of a novel bioreactor to subject aortic valve leaflets to side-specific shear stress.

Authors:  Ling Sun; Nalini M Rajamannan; Philippe Sucosky
Journal:  Ann Biomed Eng       Date:  2011-04-01       Impact factor: 3.934

7.  Duration of Systole and Diastole for Hydrodynamic Testing of Prosthetic Heart Valves: Comparison Between ISO 5840 Standards and in vivo Studies.

Authors:  Ovandir Bazan; Jayme Pinto Ortiz
Journal:  Braz J Cardiovasc Surg       Date:  2016-04

8.  Role of Computational Simulations in Heart Valve Dynamics and Design of Valvular Prostheses.

Authors:  Krishnan B Chandran
Journal:  Cardiovasc Eng Technol       Date:  2010-03       Impact factor: 2.495

9.  In vitro and in vivo investigations on the effects of low-density lipoprotein concentration polarization and haemodynamics on atherosclerotic localization in rabbit and zebrafish.

Authors:  Xiang Xie; Ju Tan; Dangheng Wei; Daoxi Lei; Tieying Yin; Junli Huang; Xiaojuan Zhang; Juhui Qiu; Chaojun Tang; Guixue Wang
Journal:  J R Soc Interface       Date:  2013-02-28       Impact factor: 4.118

10.  Purely phase-encoded MRI of turbulent flow through a dysfunctional bileaflet mechanical heart valve.

Authors:  Olusegun Adegbite; Lyes Kadem; Benedict Newling
Journal:  MAGMA       Date:  2013-09-24       Impact factor: 2.310