Literature DB >> 19532267

Calibration of scattering and absorption properties of a liquid diffusive medium at NIR wavelengths. CW method.

Fabrizio Martelli, Giovanni Zaccanti.   

Abstract

In spite of many progresses achieved both with theories and with experiments in studying light propagation through diffusive media, a reliable method for accurate measurements of the optical properties of diffusive media at NIR wavelengths is, in our opinion, still missing. It is therefore difficult to create a diffusive medium with well known optical properties to be used as a reference. In this paper we describe a method to calibrate the reduced scattering coefficient, mu'(s) , of a liquid diffusive medium and the absorption coefficient, mu(a), of an absorbing medium with a standard error smaller than 2% both on mu'(s) and on mu(a). The method is based on multidistance measurements of fluence into an infinite medium illuminated by a CW source. The optical properties are retrieved with simple inversion procedures (linear fits) exploiting the knowledge of the absorption coefficient of the liquid into which the diffuser and the absorber are dispersed. In this study Intralipid diluted in water has been used as diffusive medium and Indian ink as absorber. For a full characterization of these media measurements of collimated transmittance have also been carried out, from which the asymmetry factor of the scattering function of Intralipid and the single scattering albedo of Indian ink have been determined.

Entities:  

Year:  2007        PMID: 19532267     DOI: 10.1364/oe.15.000486

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  17 in total

1.  Phantoms for diffuse optical imaging based on totally absorbing objects, part 1: Basic concepts.

Authors:  Fabrizio Martelli; Antonio Pifferi; Davide Contini; Lorenzo Spinelli; Alessandro Torricelli; Heidrun Wabnitz; Rainer Macdonald; Angelo Sassaroli; Giovanni Zaccanti
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

2.  Design and evaluation of a laboratory prototype system for 3D photoacoustic full breast tomography.

Authors:  Wenfeng Xia; Daniele Piras; Mithun K A Singh; Johan C G van Hespen; Ton G van Leeuwen; Wiendelt Steenbergen; Srirang Manohar
Journal:  Biomed Opt Express       Date:  2013-10-23       Impact factor: 3.732

3.  Hand-held optical imager (Gen-2): improved instrumentation and target detectability.

Authors:  Jean Gonzalez; Joseph Decerce; Sarah J Erickson; Sergio L Martinez; Annie Nunez; Manuela Roman; Barbara Traub; Cecilia A Flores; Seigbeh M Roberts; Estrella Hernandez; Wenceslao Aguirre; Richard Kiszonas; Anuradha Godavarty
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

4.  Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink.

Authors:  L Spinelli; M Botwicz; N Zolek; M Kacprzak; D Milej; P Sawosz; A Liebert; U Weigel; T Durduran; F Foschum; A Kienle; F Baribeau; S Leclair; J-P Bouchard; I Noiseux; P Gallant; O Mermut; A Farina; A Pifferi; A Torricelli; R Cubeddu; H-C Ho; M Mazurenka; H Wabnitz; K Klauenberg; O Bodnar; C Elster; M Bénazech-Lavoué; Y Bérubé-Lauzière; F Lesage; D Khoptyar; A A Subash; S Andersson-Engels; P Di Ninni; F Martelli; G Zaccanti
Journal:  Biomed Opt Express       Date:  2014-06-04       Impact factor: 3.732

5.  Separation of superficial and cerebral hemodynamics using a single distance time-domain NIRS measurement.

Authors:  Alexander Jelzow; Heidrun Wabnitz; Ilias Tachtsidis; Evgeniya Kirilina; Rüdiger Brühl; Rainer Macdonald
Journal:  Biomed Opt Express       Date:  2014-04-10       Impact factor: 3.732

6.  Correction of an adding-doubling inversion algorithm for the measurement of the optical parameters of turbid media.

Authors:  Paul Lemaillet; Catherine C Cooksey; Jeeseong Hwang; Heidrun Wabnitz; Dirk Grosenick; Lin Yang; David W Allen
Journal:  Biomed Opt Express       Date:  2017-12-04       Impact factor: 3.732

7.  Algorithm for rapid determination of optical scattering parameters.

Authors:  Zachary H Levine; Richelle H Streater; Anne-Michelle R Lieberson; Adam L Pintar; Catherine C Cooksey; Paul Lemaillet
Journal:  Opt Express       Date:  2017-10-30       Impact factor: 3.894

8.  MAESTROS: A Multiwavelength Time-Domain NIRS System to Monitor Changes in Oxygenation and Oxidation State of Cytochrome-C-Oxidase.

Authors:  Frederic Lange; Luke Dunne; Lucy Hale; Ilias Tachtsidis
Journal:  IEEE J Sel Top Quantum Electron       Date:  2018-05-09       Impact factor: 4.544

9.  A hyperspectral imaging system for mapping haemoglobin and cytochrome-c-oxidase concentration changes in the exposed cerebral cortex.

Authors:  Luca Giannoni; Frédéric Lange; Marija Sajic; Kenneth J Smith; Ilias Tachtsidis
Journal:  IEEE J Sel Top Quantum Electron       Date:  2021-01-22       Impact factor: 4.544

10.  Optical characterization of two-layered turbid media for non-invasive, absolute oximetry in cerebral and extracerebral tissue.

Authors:  Bertan Hallacoglu; Angelo Sassaroli; Sergio Fantini
Journal:  PLoS One       Date:  2013-05-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.