Literature DB >> 19529577

Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source.

Sucbei Moon, Dug Young Kim.   

Abstract

We introduce a new high-speed Fourier-domain optical coherence tomography (FD-OCT) scheme based on a stretched pulse supercontinuum source. A wide-band short pulse of a supercontinuum source of which output spectrum spanned a wavelength range from 1,200 nm to 1,550 nm was stretched to a long pulse of 70-ns duration by using a dispersive fiber due to the group-velocity dispersion, and it was used directly as frequency-swept light for FD-OCT. The OCT spectral interferogram was acquired in the time domain and converted into the spectral domain by the pre-calibrated time-to-wavelength relation. Using this stretched-pulse OCT (SP-OCT) scheme, we have demonstrated an ultrahigh-speed axial-line scanning rate of 5 MHz. The axial resolution of 8 microm was achieved without re-calibration of the sweep characteristic owing to the passive nature of the frequency-sweeping mechanism.

Year:  2006        PMID: 19529577     DOI: 10.1364/oe.14.011575

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  19 in total

1.  28 MHz swept source at 1.0 μm for ultrafast quantitative phase imaging.

Authors:  Xiaoming Wei; Andy K S Lau; Yiqing Xu; Kevin K Tsia; Kenneth K Y Wong
Journal:  Biomed Opt Express       Date:  2015-09-08       Impact factor: 3.732

2.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

3.  High-performance multi-megahertz optical coherence tomography based on amplified optical time-stretch.

Authors:  Jingjiang Xu; Xiaoming Wei; Luoqin Yu; Chi Zhang; Jianbing Xu; K K Y Wong; Kevin K Tsia
Journal:  Biomed Opt Express       Date:  2015-03-18       Impact factor: 3.732

4.  Adaptive optics optical coherence tomography at 1 MHz.

Authors:  Omer P Kocaoglu; Timothy L Turner; Zhuolin Liu; Donald T Miller
Journal:  Biomed Opt Express       Date:  2014-11-06       Impact factor: 3.732

5.  Wavelength shifting of intra-cavity photons: Adiabatic wavelength tuning in rapidly wavelength-swept lasers.

Authors:  Christian Jirauschek; Robert Huber
Journal:  Biomed Opt Express       Date:  2015-06-12       Impact factor: 3.732

6.  VCSEL-based swept source for low-cost optical coherence tomography.

Authors:  Sucbei Moon; Eun Seo Choi
Journal:  Biomed Opt Express       Date:  2017-01-25       Impact factor: 3.732

Review 7.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

8.  Phase-stability optimization of swept-source optical coherence tomography.

Authors:  Sucbei Moon; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2018-10-09       Impact factor: 3.732

9.  A rapid, dispersion-based wavelength-stepped and wavelength-swept laser for optical coherence tomography.

Authors:  Serhat Tozburun; Meena Siddiqui; Benjamin J Vakoc
Journal:  Opt Express       Date:  2014-02-10       Impact factor: 3.894

10.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second.

Authors:  Benjamin Potsaid; Iwona Gorczynska; Vivek J Srinivasan; Yueli Chen; James Jiang; Alex Cable; James G Fujimoto
Journal:  Opt Express       Date:  2008-09-15       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.