Literature DB >> 19524313

On-line cone beam CT image guidance for vocal cord tumor targeting.

Sarah O S Osman1, Hans C J de Boer, Eleftheria Astreinidou, Anne Gangsaas, Ben J M Heijmen, Peter C Levendag.   

Abstract

BACKGROUND AND
PURPOSE: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections.
MATERIALS AND METHODS: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured.
RESULTS: While before correction the systematic displacements of the vocal cords were as large as 2.4+/-3.3mm (cranial-caudal population mean+/-SD Sigma), daily CBCT registration and correction reduced these values to less than 0.2+/-0.5mm in all directions. Random positioning errors (SD sigma) were reduced to less than 1mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD=0.2-0.6mm).
CONCLUSION: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation.

Entities:  

Mesh:

Year:  2009        PMID: 19524313     DOI: 10.1016/j.radonc.2009.05.015

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  9 in total

1.  Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: implications for isocenter localization accuracy.

Authors:  J Chetley Ford; Dandan Zheng; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

2.  Set-up errors and planning target volume margins in head and neck cancer radiotherapy: a clinical study of image guidance with on-line cone-beam computed tomography.

Authors:  Francesco Dionisi; Mauro Filippo Palazzi; Francesco Bracco; Maria Grazia Brambilla; Claudia Carbonini; Diego Dario Asnaghi; Angelo Filippo Monti; Alberto Torresin
Journal:  Int J Clin Oncol       Date:  2012-03-03       Impact factor: 3.402

3.  Volumetric modulated arc radiotherapy of the whole larynx, followed by a single affected vocal cord, for T1a glottic cancer: Dosimetric analysis of a case.

Authors:  Seung-Gu Yeo
Journal:  Mol Clin Oncol       Date:  2016-01-14

4.  Risk-adapted partial larynx and/or carotid artery sparing modulated radiation therapy of glottic cancer.

Authors:  Stefan Janssen; Christoph Glanzmann; Gerhard Huber; Gabriela Studer
Journal:  Radiat Oncol       Date:  2014-06-13       Impact factor: 3.481

5.  Estimation of daily interfractional larynx residual setup error after isocentric alignment for head and neck radiotherapy: quality assurance implications for target volume and organs-at-risk margination using daily CT on- rails imaging.

Authors:  Charles A Baron; Musaddiq J Awan; Abdallah S R Mohamed; Imad Akel; David I Rosenthal; G Brandon Gunn; Adam S Garden; Brandon A Dyer; Laurence Court; Parag R Sevak; Esengul Kocak-Uzel; Clifton D Fuller
Journal:  J Appl Clin Med Phys       Date:  2014-01-08       Impact factor: 2.102

6.  Set-up errors in head and neck cancer treated with IMRT technique assessed by cone-beam computed tomography: a feasible protocol.

Authors:  Durim Delishaj; Stefano Ursino; Francesco Pasqualetti; Fabrizio Matteucci; Agostino Cristaudo; Carlo Pietro Soatti; Amelia Barcellini; Fabiola Paiar
Journal:  Radiat Oncol J       Date:  2018-03-30

7.  Evaluation of MVCT imaging dose levels during helical IGRT: comparison between ion chamber, TLD, and EBT3 films.

Authors:  Jean-Pierre Mege; Sun Wenzhao; Attila Veres; Guillaume Auzac; Ibrahima Diallo; Dimitri Lefkopoulos
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

8.  Consequences of tumor planning target volume reduction in treatment of T2-T4 laryngeal cancer.

Authors:  Cornelia A J M Vugts; Chris H J Terhaard; Marielle E P Philippens; Frank A Pameijer; Nicolien Kasperts; Cornelis P J Raaijmakers
Journal:  Radiat Oncol       Date:  2014-09-04       Impact factor: 3.481

9.  Carotid-Sparing TomoHelical 3-Dimensional Conformal Radiotherapy for Early Glottic Cancer.

Authors:  Chae-Seon Hong; Dongryul Oh; Sang Gyu Ju; Yong Chan Ahn; Jae Myoung Noh; Kwangzoo Chung; Jin Sung Kim; Tae-Suk Suh
Journal:  Cancer Res Treat       Date:  2015-03-06       Impact factor: 4.679

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.