Literature DB >> 19523678

Clinical outcome of three-unit lithium-disilicate glass-ceramic fixed dental prostheses: up to 8 years results.

Stefan Wolfart1, Stefanie Eschbach, Susanne Scherrer, Matthias Kern.   

Abstract

OBJECTIVES: The purpose of this prospective study was to evaluate the clinical outcome of crown-retained fixed dental prostheses (FDPs) made from a lithium-disilicate glass-ceramic (IPS e.max Press, Ivoclar-Vivadent).
METHODS: Thirty-six three-unit FDPs were placed in 28 patients. The FDPs replaced teeth in the anterior (16%) and posterior (84%) regions. All teeth were prepared following a standardized protocol. The size of the proximal connector of the FDPs was 12 mm2 (anterior) or 16 mm2 (posterior). FDPs were cemented either with glass-ionomer cement (n=19) or composite resin (n=17). The following parameters were evaluated at baseline, 6 months after cementation and then annually (at abutment and contralateral teeth): probing pocket depth, plaque index, bleeding on probing, and tooth vitality.
RESULTS: Three FDPs were defined as drop-out. The mean observation period of the remaining 33 FDPs was 86 months (range: 67-98 months): two FDPs in two patients had to be replaced (6%) because of fractures. The 8-year survival rate according to Kaplan-Meier was 93%. In addition, chipping of the veneering material was found in two FDPs (6%). Two abutments (3%) of two restorations had to be treated endodontically; and two FDPs (6%) lost retention and had to be recemented. These complications did not affect the function of the involved restorations clinically. There were no significant differences between the periodontal parameters of the test and control teeth. SIGNIFICANCE: Short-span crown-retained three-unit FDPs made from lithium-disilicate glass-ceramic can be used clinically irrespective of an adhesive or conventional cementation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19523678     DOI: 10.1016/j.dental.2009.05.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  18 in total

1.  Clinical results of lithium-disilicate crowns after up to 9 years of service.

Authors:  Maren Gehrt; Stefan Wolfart; Nicole Rafai; Sven Reich; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-03-07       Impact factor: 3.573

2.  Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology.

Authors:  Moritz Zimmermann; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2019-07-08       Impact factor: 3.573

Review 3.  Ocular prosthesis incorporating IPS e-max press scleral veneer and a literature review on non-integrated ocular prosthesis.

Authors:  Godwin Clovis Da Costa; Meena Ajay Aras; Paul Chalakkal; Michelle Clovis Da Costa
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

4.  An in situ and ex situ study of the microstructural evolution of a novel lithium silicate glass-ceramic during crystallization firing.

Authors:  Angel L Ortiz; Camila S Rodrigues; Fernando Guiberteau; Yu Zhang
Journal:  Dent Mater       Date:  2020-04-08       Impact factor: 5.304

5.  Fatigue limit of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector.

Authors:  Marina Amaral; Regina F Villefort; Renata Marques Melo; Gabriel K R Pereira; Yu Zhang; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  J Mech Behav Biomed Mater       Date:  2017-03-07

6.  Microstructural development during heat treatment of a commercially available dental-grade lithium disilicate glass-ceramic.

Authors:  Angel L Ortiz; Oscar Borrero-López; Fernando Guiberteau; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

7.  Wear behavior of pressable lithium disilicate glass ceramic.

Authors:  Zhongxiao Peng; Muhammad Izzat Abdul Rahman; Yu Zhang; Ling Yin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-05-15       Impact factor: 3.368

8.  Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue.

Authors:  Stefan Schultheis; Joerg R Strub; Thomas A Gerds; Petra C Guess
Journal:  Clin Oral Investig       Date:  2012-09-22       Impact factor: 3.573

9.  Fracture-resistant monolithic dental crowns.

Authors:  Yu Zhang; Zhisong Mai; Amir Barani; Mark Bush; Brian Lawn
Journal:  Dent Mater       Date:  2016-01-11       Impact factor: 5.304

10.  Three-unit CAD/CAM-generated lithium disilicate FDPs after a mean observation time of 46 months.

Authors:  Sven Reich; Lutz Endres; Claudia Weber; Klaus Wiedhahn; Peter Neumann; Oliver Schneider; Nicole Rafai; Stefan Wolfart
Journal:  Clin Oral Investig       Date:  2014-02-04       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.