Literature DB >> 19522975

A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years.

Marco Aglietta1, Vincenzo Iorio Siciliano, Marcel Zwahlen, Urs Brägger, Bjarni E Pjetursson, Niklaus P Lang, Giovanni E Salvi.   

Abstract

OBJECTIVE: The aim of this systematic review was to assess the survival rates of short-span implant-supported cantilever fixed dental prostheses (ICFDPs) and the incidence of technical and biological complications after an observation period of at least 5 years.
MATERIAL AND METHODS: An electronic MEDLINE search supplemented by manual searching was conducted to identify prospective or retrospective cohort studies reporting data of at least 5 years on ICFDPs. Five- and 10-year estimates for failure and complication rates were calculated using standard or random-effect Poisson regression analysis.
RESULTS: The five studies eligible for the meta-analysis yielded an estimated 5- and 10-year ICFDP cumulative survival rate of 94.3% [95 percent confidence interval (95% CI): 84.1-98%] and 88.9% (95% CI: 70.8-96.1%), respectively. Five-year estimates for peri-implantitis were 5.4% (95% CI: 2-14.2%) and 9.4% (95% CI: 3.3-25.4%) at implant and prosthesis levels, respectively. Veneer fracture (5-year estimate: 10.3%; 95% CI: 3.9-26.6%) and screw loosening (5-year estimate: 8.2%; 95% CI: 3.9-17%) represented the most common complications, followed by loss of retention (5-year estimate: 5.7%; 95% CI: 1.9-16.5%) and abutment/screw fracture (5-year estimate: 2.1%; 95% CI: 0.9-5.1%). Implant fracture was rare (5-year estimate: 1.3%; 95% CI: 0.2-8.3%); no framework fracture was reported. Radiographic bone level changes did not yield statistically significant differences either at the prosthesis or at the implant levels when comparing ICFDPs with short-span implant-supported end-abutment fixed dental prostheses.
CONCLUSIONS: ICFDPs represent a valid treatment modality; no detrimental effects can be expected on bone levels due to the presence of a cantilever extension per se.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19522975     DOI: 10.1111/j.1600-0501.2009.01706.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  27 in total

1.  Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.

Authors:  Zhen-zhen Peng; Xin-min Chen; Jun Wang; Ai-jie Li; Zu-jie Xu
Journal:  J Zhejiang Univ Sci B       Date:  2013-06       Impact factor: 3.066

2.  The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices.

Authors:  Minoo Mahshid; Aboulfazl Saboury; Seyed Jalil Sadr; Ali Fayyaz; Mahdi Kadkhodazadeh
Journal:  J Periodontal Implant Sci       Date:  2013-10-29       Impact factor: 2.614

3.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

4.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

5.  Survey of Screw-Retained versus Cement-Retained Implant Restorations in Saudi Arabia.

Authors:  Alaa Makke; Abdulwahed Homsi; Montaha Guzaiz; Abdulrahman Almalki
Journal:  Int J Dent       Date:  2017-10-30

6.  Prevalence of complications after the oral rehabilitation with implant-supported hybrid prostheses.

Authors:  Júlia Real-Osuna; Nieves Almendros-Marqués; Cosme Gay-Escoda
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-01-01

7.  A 3-year prospective cohort study on mandibular anterior cantilever restorations associated with screw-retained implant-supported prosthesis: An in vivo study.

Authors:  Vizaikumar Vasudha Nelluri; Kandathilparambil Maria Roseme; Rajani Kumar Gedela
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

8.  The effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.

Authors:  Aboulfazl Saboury; Seyed Jalil Sadr; Ali Fayaz; Minoo Mahshid
Journal:  J Dent (Tehran)       Date:  2013-01-31

9.  The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants.

Authors:  Minoo Mahshid; Aboulfazl Saboury; Ali Fayaz; Seyed Jalil Sadr; Friedrich Lampert; Maziar Mir
Journal:  Clin Cosmet Investig Dent       Date:  2012-07-31

10.  Biological and immunotoxicity evaluation of antimicrobial peptide-loaded coatings using a layer-by-layer process on titanium.

Authors:  Jue Shi; Yu Liu; Ying Wang; Jing Zhang; Shifang Zhao; Guoli Yang
Journal:  Sci Rep       Date:  2015-11-09       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.