Literature DB >> 19521011

Monte Carlo modeling of cascade gamma rays in (86)Y PET imaging: preliminary results.

Xuping Zhu1, Georges El Fakhri.   

Abstract

(86)Y is a PET agent that could be used as an ideal surrogate to allow personalized dosimetry in (90)Y radionuclide therapy. However, (86)Y also emits cascade gamma rays. We have developed a Monte Carlo program based on SimSET (Simulation System for Emission Tomography) to model cascade gamma rays in PET imaging. The new simulation was validated with the GATE simulation package. Agreements within 15% were found in spatial resolution, apparent scatter fraction (ratio of coincidences outside peak regions in line source sinograms), single and coincidence statistics and detected photons energy distribution within the PET energy window. A discrepancy of 20% was observed in the absolute scatter fraction, likely caused by differences in the tracking of higher energy cascade gamma photons. On average, the new simulation is 6 times faster than GATE, and the computing time can be further improved by using variance reduction techniques currently available in SimSET. Comparison with phantom acquisitions showed agreements in spatial resolutions and the general shape of projection profiles; however, the standard scatter correction method on the scanner is not directly applicable to (86)Y PET as it leads to incorrect scatter fractions. The new simulation was used to characterize (86)Y PET. Compared with conventional (18)F PET, in which major contamination at low count rates comes from scattered events, cascade gamma-involved events are more important in (86)Y PET. The two types of contaminations have completely different distribution patterns, which should be considered for the corrections of their effects. Our approach will be further improved in the future in the modeling of random coincidences and tracking of high-energy photons, and simulation results will be used for the development of correction methods in (86)Y PET.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19521011      PMCID: PMC3111055          DOI: 10.1088/0031-9155/54/13/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Quantitative imaging and correction for cascade gamma radiation of 76Br with 2D and 3D PET.

Authors:  Mark Lubberink; Harald Schneider; Mats Bergström; Hans Lundqvist
Journal:  Phys Med Biol       Date:  2002-10-07       Impact factor: 3.609

Review 2.  Diagnostic and therapeutic applications of radiolabeled somatostatin analogs: current status in an oncology center.

Authors:  Donald A Podoloff
Journal:  Curr Pharm Des       Date:  2002       Impact factor: 3.116

3.  Quantitative imaging of yttrium-86 PET with the ECAT EXACT HR+ in 2D mode.

Authors:  Thomas Kull; Jochen Ruckgaber; Rolf Weller; Sven Reske; Gerhard Glatting
Journal:  Cancer Biother Radiopharm       Date:  2004-08       Impact factor: 3.099

4.  Design and Implementation of a Block Detector Simulation in SimSET.

Authors:  Robert L Harrison; Steven B Gillispie; Thomas K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2006

5.  Modeling block detectors in SimSET.

Authors:  Robert Harrison; Steven Gillispie; Ruth Schmitz; Thomas Lewellen
Journal:  J Nucl Med       Date:  2008       Impact factor: 10.057

6.  (124)I in PET imaging: impact on quantification, radiopharmaceutical development and distribution.

Authors:  Andreas Bockisch; Lutz Freudenberg; Sandra Rosenbaum; Walter Jentzen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-11       Impact factor: 9.236

7.  Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections.

Authors:  M Bergström; L Eriksson; C Bohm; G Blomqvist; J Litton
Journal:  J Comput Assist Tomogr       Date:  1983-02       Impact factor: 1.826

Review 8.  Radioimmunotherapy: a new treatment modality for B-cell non-Hodgkin's lymphoma.

Authors:  Irene Ghobrial; Thomas Witzig
Journal:  Oncology (Williston Park)       Date:  2004-05       Impact factor: 2.990

9.  Three-dimensional positron emission tomography imaging with 124I and 86Y.

Authors:  Stefaan Vandenberghe
Journal:  Nucl Med Commun       Date:  2006-03       Impact factor: 1.690

10.  Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86.

Authors:  Stéphan Walrand; François Jamar; Isabelle Mathieu; Joëlle De Camps; Max Lonneux; Mérence Sibomana; Daniel Labar; Christian Michel; Stanislas Pauwels
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-12-17       Impact factor: 9.236

View more
  3 in total

1.  Impact of Region-of-Interest Delineation Methods, Reconstruction Algorithms, and Intra- and Inter-Operator Variability on Internal Dosimetry Estimates Using PET.

Authors:  N López-Vilanova; J Pavía; M A Duch; A Catafau; D Ros; S Bullich
Journal:  Mol Imaging Biol       Date:  2017-04       Impact factor: 3.488

Review 2.  Quantitative imaging of 124I and 86Y with PET.

Authors:  Mark Lubberink; Hans Herzog
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

Review 3.  Physics of pure and non-pure positron emitters for PET: a review and a discussion.

Authors:  Maurizio Conti; Lars Eriksson
Journal:  EJNMMI Phys       Date:  2016-05-23