Literature DB >> 21151857

Modeling block detectors in SimSET.

Robert Harrison1, Steven Gillispie, Ruth Schmitz, Thomas Lewellen.   

Abstract

OBJECTIVES: We have added a block detector model to the Simulation System for Emission Tomography (SimSET) software version 2.9.
METHODS: The new model simulates the detector system as a collection of right rectangular boxes and allows for very flexible positioning of these boxes. This model allows users to simulate typical block-based cylindrical tomographs, pixelated positron emission mammography (PEM) detectors, and many more imaginative tomograph designs. We have tested the block detector software against analytically derived results and against SimSET simulations of dual-headed and cylindrical detector tomographs. We have also compared experimental and simulated sensitivities for a General Electric DSTE PET for 3 different phantom diameters in 2d and 3d acquisition modes.
RESULTS: The tests against analytically derived results and against simulations were validated both statistically using the t-test and visually by comparing profiles through the sinograms. Within the limits of statistical fluctuation, the new software passed all tests. In comparisons with data from the PET scanner, the simulation showed better agreement than previous SimSET releases, but still showed substantially increased coincidence sensitivity.
CONCLUSIONS: We believe the increased sensitivity is a result of the very simple default models used for energy resolution and scintillation light collection, and the lack of any livetime correction. The new release provides a user-modifiable function where all these factors can be realistically modeled for a given tomograph. The SimSET software, including source code, remains in the public domain.

Year:  2008        PMID: 21151857      PMCID: PMC2999359     

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  2 in total

1.  Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

Authors:  Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov
Journal:  Med Phys       Date:  2017-05-18       Impact factor: 4.071

2.  Monte Carlo modeling of cascade gamma rays in (86)Y PET imaging: preliminary results.

Authors:  Xuping Zhu; Georges El Fakhri
Journal:  Phys Med Biol       Date:  2009-06-12       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.