Abnormal kinematics of the artificial knee. Roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS knees.

K G Nilsson1, J Kärrholm, P Gadegaard.   

Abstract

The in vivo kinematics of two types of unconstrained, posterior cruciate ligament retaining knee prostheses were analyzed 1 year postoperatively using roentgen stereophotogrammetric analysis. Ten knees had the Miller-Galante and five the New Jersey LCS design. The Miller-Galante knees displayed decreased adduction during active flexion when compared with normal knees. In both types of prostheses, there was decreased medial and increased proximal and posterior displacement. The abnormal kinematics probably reflect the design of the articular surfaces, the absence of the anterior cruciate ligament, and the dysfunction of the posterior cruciate ligament.

Mesh:

Year:  1991        PMID: 1950487     DOI: 10.3109/17453679108996640

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  11 in total

1.  Changes in knee kinematics reflect the articular geometry after arthroplasty.

Authors:  Anthony M J Bull; Oliver Kessler; Mahbub Alam; Andrew A Amis
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

2.  Control of paradoxical kinematics in posterior cruciate-retaining total knee arthroplasty by increasing posterior femoral offset.

Authors:  J Donadio; A Pelissier; P Boyer; P Massin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-14       Impact factor: 4.342

3.  Changes in varus-valgus laxity after total knee arthroplasty over time.

Authors:  Mitsuhiro Takeda; Yoshinori Ishii; Hideo Noguchi; Yoshikazu Matsuda; Junko Sato
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-25       Impact factor: 4.342

4.  Will early reconstruction prevent abnormal kinematics after ACL injury? Two-year follow-up using dynamic radiostereometry in 14 patients operated with hamstring autografts.

Authors:  Jonas Isberg; Eva Faxén; Gauti Laxdal; Bengt I Eriksson; Johan Kärrholm; Jon Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-18       Impact factor: 4.342

5.  Lack of axial rotation in mobile-bearing knee designs.

Authors:  Ray C Wasielewski; Richard D Komistek; Sumesh M Zingde; Kate C Sheridan; Mohamed R Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2008-06-26       Impact factor: 4.176

6.  Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty.

Authors:  Hua-Wei Liu; Ming Ni; Guo-Qiang Zhang; Xiang Li; Hui Chen; Qiang Zhang; Wei Chai; Yong-Gang Zhou; Ji-Ying Chen; Yu-Liang Liu; Cheng-Kung Cheng; Yan Wang
Journal:  Am J Transl Res       Date:  2016-05-15       Impact factor: 4.060

7.  Comparison of tibial rotation in fixed and mobile bearing total knee arthroplasty using computer navigation.

Authors:  James B Stiehl
Journal:  Int Orthop       Date:  2008-07-11       Impact factor: 3.075

8.  Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

Authors:  Valentina Ngai; Markus A Wimmer
Journal:  J Biomech       Date:  2009-08-03       Impact factor: 2.712

9.  Kinematics of successful knee prostheses during weight-bearing: three-dimensional movements and positions of screw axes in the Tricon-M and Miller-Galante designs.

Authors:  J Kärrholm; H Jonsson; K G Nilsson; I Söderqvist
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1994       Impact factor: 4.342

10.  The Mark Coventry Award: Articular contact estimation in TKA using in vivo kinematics and finite element analysis.

Authors:  Fabio Catani; Bernardo Innocenti; Claudio Belvedere; Luc Labey; Andrea Ensini; Alberto Leardini
Journal:  Clin Orthop Relat Res       Date:  2009-06-23       Impact factor: 4.176