Literature DB >> 19500231

Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?

Pietro Francia1, Cristina Balla, Arianna Uccellini, Riccardo Cappato.   

Abstract

The implantable cardioverter defibrillator (ICD) offers life-saving therapies for primary and secondary prevention of sudden cardiac death in high-risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single-chamber ICD (Sc-ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachycardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual-chamber ICDs (Dc-ICDs) are supposed to overcome specificity issues by enhancing detection algorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc-ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc-ICDs in a more selective use of aggressive therapies. Despite this solid background, superiority of Dc- over Sc-ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc-ICDs in preventing inappropriate therapies.

Entities:  

Mesh:

Year:  2009        PMID: 19500231     DOI: 10.1111/j.1540-8167.2009.01477.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  6 in total

Review 1.  Basic Properties And Clinical Applications Of The Intracardiac.

Authors:  Francesco Zanon; Lina Marcantoni; Gianni Pastore; Enrico Baracca; Silvio Aggio; Franco Di Gregorio; Alberto Barbetta; Mauro Carraro; Claudio Picariello; Luca Conte; Loris Roncon
Journal:  J Atr Fibrillation       Date:  2016-12-31

2.  Common genetic variants in selected Ca²⁺ signaling genes and the risk of appropriate ICD interventions in patients with heart failure.

Authors:  Pietro Francia; Carmen Adduci; Agnese Ricotta; Rosita Stanzione; Isabella Sensini; Arianna Uccellini; Alessandra Frattari; Cristina Balla; Maria Cotugno; Riccardo Cappato; Speranza Rubattu; Massimo Volpe
Journal:  J Interv Card Electrophysiol       Date:  2013-09-19       Impact factor: 1.900

3.  Electrical And Hemodynamic Evalution Of Ventricular And Supraventricular Tachycardias With An Implantable Dual-Chamber Pacemaker.

Authors:  Claudio Pandozi; Franco Di Gregorio; Carlo Lavalle; Renato Pietro Ricci; Sabina Ficili; Marco Galeazzi; Maurizio Russo; Angela Pandozi; Furio Colivicchi; Massimo Santini
Journal:  J Atr Fibrillation       Date:  2014-06-30

4.  Single-chamber ICD, single-zone therapy in primary and secondary prevention patients: the simpler the better?

Authors:  S González-Enríquez; F Rodríguez-Entem; V Expósito; C Castrillo-Bustamante; A Canteli; A Solloso; I Madrazo; J J Olalla
Journal:  J Interv Card Electrophysiol       Date:  2012-10-19       Impact factor: 1.900

Review 5.  The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new-onset atrial high-rate episodes or subclinical atrial fibrillation: A systematic review and meta-analysis.

Authors:  Xuanming Pung; Daniel Zhihao Hong; Tzyy Yeou Ho; Xiayan Shen; Pei Ting Tan; Colin Yeo; Vern Hsen Tan
Journal:  J Arrhythm       Date:  2022-01-15

6.  The efficacy of the LinoxSmart DX ICD lead from a single center experience.

Authors:  Ibrahim Marai; Anat Milman; Rafael Diamante; Osnat Gurevitz; David Barlev; Igor Lipchenka; Eyal Nof; Michael Glikson; Roy Beinart
Journal:  Indian Pacing Electrophysiol J       Date:  2019-12-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.