Literature DB >> 23080327

Single-chamber ICD, single-zone therapy in primary and secondary prevention patients: the simpler the better?

S González-Enríquez1, F Rodríguez-Entem, V Expósito, C Castrillo-Bustamante, A Canteli, A Solloso, I Madrazo, J J Olalla.   

Abstract

BACKGROUND: It is now well established that implantable cardioverter defibrillator (ICD) implantation reduces mortality in patients at increased risk of sudden cardiac death. However, the best programming parameters remain controversial. Our traditional policy has followed a simple approach in the vast majority of patients. In accordance with ICD programming in the major randomized clinical trials, we programmed a single high-rate, shock-only therapy zone. We aimed to demonstrate in this observational study that simple programming is not associated with higher shock rates or mortality when compared to other published studies.
METHODS: Consecutive patients who underwent single-chamber ICD implantation with single-zone, high-rate programming at our institution between 1993 and 2008 were retrospectively studied. Data were collected prospectively in a database regarding details of ICD implantation, demographic data, and indication.
RESULTS: Three hundred thirty-two patients were included in our study, 31 % primary prevention and 68 % secondary prevention. Mean ejection fraction (EF) is 33.7 ± 15.3. Over a mean follow-up period of 62.5 ± 38.1 months, 135 patients experienced ICD shock (annualized event rate 7.7 %); 89 patients (26.8 %) appropriate shock in VT-ventricular fibrillation (VF), 68 patients (20.5 %) inappropriate shocks, and 22 patients (6.6 %) both. Twenty-nine patients (8.7 %) were reprogrammed to additional VT-ATP zones. Twenty-two (6.6 %) patients underwent heart transplantation. Sixty-two patients (18.6 %) died during follow-up, 43.6 % out of them due to cardiac cause, mainly progressive heart failure.
CONCLUSION: Our results show that simpler settings with single-zone, high-rate programming is associated with ICD shock rates and long-term mortality that does not appear to be worse when compared with contemporary studies which include multizone ICD programming with antitachycardia pacing activated.

Entities:  

Mesh:

Year:  2012        PMID: 23080327     DOI: 10.1007/s10840-012-9735-9

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  35 in total

1.  Ventricular tachycardias above the initially programmed tachycardia detection interval in patients with implantable cardioverter-defibrillators: incidence, prediction and significance.

Authors:  D Bänsch; M Castrucci; D Böcker; G Breithardt; M Block
Journal:  J Am Coll Cardiol       Date:  2000-08       Impact factor: 24.094

2.  Do traditional VT zones improve outcome in primary prevention ICD patients?

Authors:  Edward Duncan; Glyn Thomas; Neville Johns; Cameron Pfeffer; Gautham Appanna; Nirav Shah; Ross Hunter; Malcolm Finlay; Richard J Schilling; Simon Sporton
Journal:  Pacing Clin Electrophysiol       Date:  2010-08-18       Impact factor: 1.976

3.  ACC/AHA/HRS 2008 Guidelines for device-based therapy of cardiac rhythm abnormalities.

Authors:  Andrew E Epstein; John P Dimarco; Kenneth A Ellenbogen; N A Mark Estes; Roger A Freedman; Leonard S Gettes; A Marc Gillinov; Gabriel Gregoratos; Stephen C Hammill; David L Hayes; Mark A Hlatky; L Kristin Newby; Richard L Page; Mark H Schoenfeld; Michael J Silka; Lynne Warner Stevenson; Michael O Sweeney
Journal:  Heart Rhythm       Date:  2008-05-21       Impact factor: 6.343

4.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

5.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.

Authors: 
Journal:  N Engl J Med       Date:  1997-11-27       Impact factor: 91.245

6.  Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators: the OPTIC Study: a randomized trial.

Authors:  Stuart J Connolly; Paul Dorian; Robin S Roberts; Michael Gent; Steven Bailin; Eric S Fain; Kevin Thorpe; Jean Champagne; Mario Talajic; Benoit Coutu; Gerian C Gronefeld; Stefan H Hohnloser
Journal:  JAMA       Date:  2006-01-11       Impact factor: 56.272

7.  Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.

Authors:  James P Daubert; Wojciech Zareba; David S Cannom; Scott McNitt; Spencer Z Rosero; Paul Wang; Claudio Schuger; Jonathan S Steinberg; Steven L Higgins; David J Wilber; Helmut Klein; Mark L Andrews; W Jackson Hall; Arthur J Moss
Journal:  J Am Coll Cardiol       Date:  2008-04-08       Impact factor: 24.094

8.  Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study.

Authors:  Bruce L Wilkoff; Brian D Williamson; Richard S Stern; Stephen L Moore; Fei Lu; Sung W Lee; Ulrika M Birgersdotter-Green; Mark S Wathen; Isabelle C Van Gelder; Brooke M Heubner; Mark L Brown; Keith K Holloman
Journal:  J Am Coll Cardiol       Date:  2008-08-12       Impact factor: 24.094

9.  Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.

Authors:  Alan Kadish; Alan Dyer; James P Daubert; Rebecca Quigg; N A Mark Estes; Kelley P Anderson; Hugh Calkins; David Hoch; Jeffrey Goldberger; Alaa Shalaby; William E Sanders; Andi Schaechter; Joseph H Levine
Journal:  N Engl J Med       Date:  2004-05-20       Impact factor: 91.245

10.  Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp DeliVery for pAiNless ICD thErapy (ADVANCE-D) Trial results.

Authors:  Massimo Santini; Maurizio Lunati; Pascal Defaye; Johann Mermi; Alessandro Proclemer; Silvia del Castillo-Arroys; Giulio Molon; Elisabetta Santi; Tiziana De Santo; Xavier Navarro; Axel Kloppe
Journal:  J Interv Card Electrophysiol       Date:  2010-01-20       Impact factor: 1.900

View more
  2 in total

1.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01

Review 2.  Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis.

Authors:  Angelo Auricchio; J Harrison Hudnall; Edward J Schloss; Laurence D Sterns; Takashi Kurita; Albert Meijer; Dedra H Fagan; Tyson Rogers
Journal:  Europace       Date:  2017-12-01       Impact factor: 5.214

  2 in total