Literature DB >> 19499835

Influence of cup orientation on the wear performance of metal-on-metal hip replacements.

A Angadji1, M Royle, S N Collins, J C Shelton.   

Abstract

There are a number of factors that determine the overall outcome of total hip replacement (THR) surgery, some of which appear to be related to the surgical procedure. In particular, the inclination angle at which the acetabular component is placed has been reported to influence the long-term successful performance of THR. The present study assessed the influence of cup orientation on the wear of 40 mm diameter metal-on-metal (MoM) hip bearings tested in a hip simulator. The bearings had a mean radial clearance of 150 microm; the cups oriented at 35 degrees, 50 degrees, and 60 degrees to the horizontal were loaded for up to 6 x 10(6) cycles. In each test the wear rates during the run-in phase were higher than in the steady state phase; the wear rates during the run-in phase were not significantly different for each cup orientation. However, at cup angles of 50 degrees and 60 degrees, the steady state wear rates were 0.69 mm3/ 10(6) cycles and 1.7 mm3/10(6) cycles respectively, significantly higher than at 35 degrees (0.24 mm3/10(6) cycles). The results indicated that larger cup inclination angles not only move the position of the wear scar but also, more significantly in MoM bearings, increase the wear rates and total wear volume generated.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19499835     DOI: 10.1243/09544119JEIM518

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  17 in total

Review 1.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

2.  How Reliable is the Acetabular Cup Position Assessment from Routine Radiographs?

Authors:  Jaime A Carvajal Alba; Heather K Vincent; Jagdeep S Sodhi; Loren L Latta; Hari K Parvataneni
Journal:  Iowa Orthop J       Date:  2017

3.  Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing.

Authors:  Alister J Hart; John A Skinner; Johann Henckel; Barry Sampson; Fabiana Gordon
Journal:  Clin Orthop Relat Res       Date:  2011-06-09       Impact factor: 4.176

4.  A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

Authors:  S G Clarke; A T M Phillips; A M J Bull; J P Cobb
Journal:  J Biomech       Date:  2012-04-16       Impact factor: 2.712

5.  Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up.

Authors:  Alessandro Bistolfi; Riccardo Ferracini; Alessandro Aprato; Alessandro Massè; Walter Daghino; Sara Lea; Stefano Artiaco; Gwo-Chin Lee
Journal:  J Orthop       Date:  2020-08-28

6.  What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Authors:  Nick Bayley; Habeeb Khan; Paul Grosso; Thomas Hupel; David Stevens; Matthew Snider; Emil Schemitsch; Paul Kuzyk
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

7.  False profile view is independently associated with serum metal levels in patients with metal-on-metal hip arthroplasty.

Authors:  Arne Borgwardt; Bo Madvig Larsen; Søren Ribel-Madsen; Bo Zerahn
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-11-26

Review 8.  Metal on metal hip resurfacing arthroplasty: Where are we now?

Authors:  E J Clough; T M Clough
Journal:  J Orthop       Date:  2020-12-31

9.  Investigation of creep mechanical characteristics of femoral prostheses by simulated hip replacement.

Authors:  Guang-Yao Liu; Yan Jin; Peng Li
Journal:  Exp Ther Med       Date:  2013-02-19       Impact factor: 2.447

10.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Sophie Williams; Joanne L Tipper; Louise M Jennings
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-12-20       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.