Literature DB >> 19485230

Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets.

Pei Chen1, Renata Atkinson, Wayne R Wolf.   

Abstract

The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19485230      PMCID: PMC4159756     

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  9 in total

1.  Determination of vitamin B12 in multivitamin tablets by multimode high-performance liquid chromatography.

Authors:  S Wongyai
Journal:  J Chromatogr A       Date:  2000-02-18       Impact factor: 4.759

2.  Determination of vitamin B12 in multivitamin tablets and fermentation medium by high-performance liquid chromatography with fluorescence detection.

Authors:  H B Li; F Chen; Y Jiang
Journal:  J Chromatogr A       Date:  2000-09-08       Impact factor: 4.759

3.  LC/UV/MS-MRM for the simultaneous determination of water-soluble vitamins in multi-vitamin dietary supplements.

Authors:  Pei Chen; Wayne R Wolf
Journal:  Anal Bioanal Chem       Date:  2006-11-08       Impact factor: 4.142

4.  Determination of vitamin B6 (pyridoxamine, pyridoxal and pyridoxine) in pork meat and pork meat products by liquid chromatography.

Authors:  M J Esteve; R Farré; A Frígola; J M García-Cantabella
Journal:  J Chromatogr A       Date:  1998-02-06       Impact factor: 4.759

5.  Determination of water-soluble vitamins in infant milk by high-performance liquid chromatography.

Authors:  S Albalá-Hurtado; M T Veciana-Nogués; M Izquierdo-Pulido; A Mariné-Font
Journal:  J Chromatogr A       Date:  1997-08-22       Impact factor: 4.759

6.  Progress in development of an integrated dietary supplement ingredient database at the NIH Office of Dietary Supplements.

Authors:  Johanna T Dwyer; Mary Frances Picciano; Joseph M Betz; Kenneth D Fisher; Leila G Saldanha; Elizabeth A Yetley; Paul M Coates; Kathy Radimer; Bernadette Bindewald; Katherine E Sharpless; Joanne Holden; Karen Andrews; Cuiwei Zhao; James Harnly; Wayne R Wolf; Charles R Perry
Journal:  J Food Compost Anal       Date:  2006-08-01       Impact factor: 4.556

7.  Determination of eight water- and fat-soluble vitamins in multi-vitamin pharmaceutical formulations by high-performance liquid chromatography.

Authors:  P Moreno; V Salvadó
Journal:  J Chromatogr A       Date:  2000-02-18       Impact factor: 4.759

8.  Development of a validated HPLC method for the determination of B-complex vitamins in pharmaceuticals and biological fluids after solid phase extraction.

Authors:  Pavlos F Chatzimichalakis; Victoria F Samanidou; Robert Verpoorte; Ioannis N Papadoyannis
Journal:  J Sep Sci       Date:  2004-10       Impact factor: 3.645

9.  Contents of selected B vitamins in NIST SRM 3280 multivitamin/multielement tablets by liquid chromatography isotope dilution mass spectrometry.

Authors:  Pei Chen; Mustafa Ozcan; Wayne R Wolf
Journal:  Anal Bioanal Chem       Date:  2007-07-24       Impact factor: 4.142

  9 in total
  9 in total

1.  Dietary supplement laboratory quality assurance program: the first five exercises.

Authors:  Melissa M Phillips; Catherine A Rimmer; Laura J Wood; Katrice A Lippa; Katherine E Sharpless; David L Duewer; Lane C Sander; Joseph M Betz
Journal:  J AOAC Int       Date:  2011 May-Jun       Impact factor: 1.913

2.  A novel and sensitive method for determining vitamin B3 and B7 by pre-column derivatization and high-performance liquid chromatography method with fluorescence detection.

Authors:  Baolei Fan; Jinmao You; Yourui Suo; Chunqi Qian
Journal:  PLoS One       Date:  2018-06-06       Impact factor: 3.240

3.  Clostridioides difficile Activates Human Mucosal-Associated Invariant T Cells.

Authors:  Isabel Bernal; Julia Danielle Hofmann; Björn Bulitta; Frank Klawonn; Annika-Marisa Michel; Dieter Jahn; Meina Neumann-Schaal; Dunja Bruder; Lothar Jänsch
Journal:  Front Microbiol       Date:  2018-10-25       Impact factor: 5.640

4.  Evaluation of Extrusion Temperatures, Pelleting Parameters, and Vitamin Forms on Vitamin Stability in Feed.

Authors:  Pan Yang; Huakai Wang; Min Zhu; Yongxi Ma
Journal:  Animals (Basel)       Date:  2020-05-20       Impact factor: 2.752

Review 5.  The Importance of Reference Materials and Method Validation for Advancing Research on the Health Effects of Dietary Supplements and Other Natural Products.

Authors:  Sanem Hosbas Coskun; Stephen A Wise; Adam J Kuszak
Journal:  Front Nutr       Date:  2021-12-14

6.  Effects of Pelleting and Long-Term High-Temperature Stabilization on Vitamin Retention in Swine Feed.

Authors:  Huakai Wang; Longxian Li; Nan Zhang; Tuan Zhang; Yongxi Ma
Journal:  Animals (Basel)       Date:  2022-04-20       Impact factor: 2.752

7.  Feasibility of Mass-Spectrometry to Lower Cost and Blood Volume Requirements for Assessment of B Vitamins in Patients Undergoing Bariatric Surgery.

Authors:  Seth Armah; Mario G Ferruzzi; Nana Gletsu-Miller
Journal:  Metabolites       Date:  2020-06-10

8.  Effects of Choline Chloride, Copper Sulfate and Zinc Oxide on Long-Term Stabilization of Microencapsulated Vitamins in Premixes for Weanling Piglets.

Authors:  Pan Yang; Huakai Wang; Min Zhu; Yongxi Ma
Journal:  Animals (Basel)       Date:  2019-12-16       Impact factor: 2.752

9.  Degradation kinetics of vitamins in premixes for pig: effects of choline, high concentrations of copper and zinc, and storage time.

Authors:  Pan Yang; Hua Kai Wang; Min Zhu; Long Xian Li; Yong Xi Ma
Journal:  Anim Biosci       Date:  2020-06-24
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.