Literature DB >> 17646973

Contents of selected B vitamins in NIST SRM 3280 multivitamin/multielement tablets by liquid chromatography isotope dilution mass spectrometry.

Pei Chen1, Mustafa Ozcan, Wayne R Wolf.   

Abstract

There is increased interest in accurately assessing the total dietary intake of vitamins from all sources, including foods and dietary supplements. Consequently, a Dietary Supplement Ingredient Database (DSID), based upon analytical values, is being established by USDA with support of the Office of Dietary Supplements (ODS), NIH. The DSID necessitated the development of a new SRM, 3280--Multivitamin/Multimineral Tablets, by the National Institute of Standards and Technology (NIST), with support from the ODS. As a continuation of a long-term project to develop and validate new methods of determining water-soluble B vitamins in foods and dietary supplements, and as part of a collaborative effort with NIST to characterize SRM 3280, values for the vitamin contents of SRM 3280 have been generated by a liquid chromatographic isotope dilution mass spectrometric (LC/IDMS) method. Isotope-labeled ((13)C and/or (2)H) B vitamins (B1-thiamine, B6-pyridoxine, B3-nicotinamide, and B5-pantothenic acid) were obtained from commercial sources, with the support of the ODS/NIH. Our LC/IDMS method uses a C18 reversed phase column, an Agilent 1100 HPLC system, and a Quattro Micro triple-quad mass spectrometer (MS). B vitamin determination was achieved using a gradient LC profile combined with MS/MS detection in multiple reaction monitoring mode. Stock solutions of the isotope-labeled vitamins were calibrated against USP standard solutions. The SRM tablets, with added amounts of the four isotope-labeled B vitamins, were extracted and the vitamins simultaneously determined in a single LC run, in contrast with the single-component determinations performed via IDMS. Unknown vitamin concentrations were calculated by comparing the ratios of the integrated LC peaks at the different masses of the unlabeled and labeled vitamins.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17646973     DOI: 10.1007/s00216-007-1430-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Dietary supplement laboratory quality assurance program: the first five exercises.

Authors:  Melissa M Phillips; Catherine A Rimmer; Laura J Wood; Katrice A Lippa; Katherine E Sharpless; David L Duewer; Lane C Sander; Joseph M Betz
Journal:  J AOAC Int       Date:  2011 May-Jun       Impact factor: 1.913

2.  Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets.

Authors:  Pei Chen; Renata Atkinson; Wayne R Wolf
Journal:  J AOAC Int       Date:  2009 Mar-Apr       Impact factor: 1.913

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.