Literature DB >> 19473914

Phase coherence imaging.

Jorge Camacho1, Montserrat Parrilla, Carlos Fritsch.   

Abstract

A new method for grating and side lobes suppression in ultrasound images is presented. It is based on an analysis of the phase diversity at the aperture data. Two coherence factors, namely the phase coherence factor (PCF) and the sign coherence factor (SCF), are proposed to weight the coherent sum output. Different from other approaches, phase rather than amplitude information is used to perform the correction action. Besides achieving the main goal, the method obtains improvements in lateral resolution and SNR. Implementation of the SCF technique is quite straightforward, operating in realtime, and can be added to any virtually existing beamformer to improve the resolution, contrast, SNR, and dynamic range of the images. A programmable parameter allows adjusting the sensitivity of the method to out-of-phase signals, from zero to a strict coherence criterion. The theoretical basis for the 2 methods are given and their performances evaluated by simulation. Then, experiments are conducted to provide results that are in good agreement with those expected from theory and simulation.

Entities:  

Mesh:

Year:  2009        PMID: 19473914     DOI: 10.1109/TUFFC.2009.1128

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  48 in total

1.  Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2015-10-07       Impact factor: 1.314

2.  Synthetic aperture focusing for short-lag spatial coherence imaging.

Authors:  Nick Bottenus; Brett C Byram; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

3.  Adaptive windowing in contrast-enhanced intravascular ultrasound imaging.

Authors:  Brooks D Lindsey; K Heath Martin; Xiaoning Jiang; Paul A Dayton
Journal:  Ultrasonics       Date:  2016-04-27       Impact factor: 2.890

4.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

5.  Equivalence of time and aperture domain additive noise in ultrasound coherence.

Authors:  Nick B Bottenus; Gregg E Trahey
Journal:  J Acoust Soc Am       Date:  2015-01       Impact factor: 1.840

6.  Pseudononlinear ultrasound simulation approach for reverberation clutter.

Authors:  Brett Byram; Jasmine Shu
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-08

7.  Apodized adaptive beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2017-01-13       Impact factor: 1.314

8.  Ultrasonic Reverberation Clutter Suppression Using Multiphase Apodization With Cross Correlation.

Authors:  Junseob Shin; Yu Chen; Harshawn Malhi; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

9.  Improvement of penetration of modified amplitude and phase estimation beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2016-07-21       Impact factor: 1.314

10.  A Robust Method for Ultrasound Beamforming in the Presence of Off-Axis Clutter and Sound Speed Variation.

Authors:  Kazuyuki Dei; Brett Byram
Journal:  Ultrasonics       Date:  2018-04-25       Impact factor: 2.890

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.