Hardware and software artifacts in storage phosphor radiography.

J W Oestmann1, M Prokop, C M Schaefer, M Galanski.   

Abstract

Hardware and software artifacts in digital radiographs acquired with storage phosphor systems can seriously impair image quality and imitate or mask abnormalities. These artifacts are caused by image plate, image reader, and laser printer defects; faulty image readout; processing errors; and unsharp masking. The artifacts can simulate calcifications and pneumothoraces or conceal low-contrast ill-defined lesions and subtle lesions along opacity interfaces. Hardware artifacts need to be recognized and properly traced to repair the system or improve its maintenance. Artifacts due to software characteristics and image post-processing must also be identified to ensure adequate system handling and adjustment of postprocessing algorithms.

Entities:  

Mesh:

Year:  1991        PMID: 1947316     DOI: 10.1148/radiographics.11.5.1947316

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  5 in total

1.  Artifacts found during quality assurance testing of computed radiography and digital radiography detectors.

Authors:  Ian D Honey; Alistair Mackenzie
Journal:  J Digit Imaging       Date:  2008-04-22       Impact factor: 4.056

2.  Imaging evaluating of the implant/bone interface-an in vitro radiographic study.

Authors:  Michele M Vidor; Gabriela S Liedke; Mariana B Vizzotto; Heraldo L D da Silveira; Priscila F da Silveira; Cristiano W Araujo; Heloisa E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2017-03-28       Impact factor: 2.419

3.  Definition, classification and retrospective analysis of photostimulable phosphor image artefacts and errors in intraoral dental radiography.

Authors:  Armağan Çalışkan; A Pinar Sumer
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

4.  Analysis of photostimulable phosphor image plate artifacts and their prevalence.

Authors:  Sara Mohamed Elkhateeb; Ashwag Yagoub Aloyouny; Mohamed Mohamed Saeed Omer; Soad Mahmoud Mansour
Journal:  World J Clin Cases       Date:  2022-01-14       Impact factor: 1.337

5.  Effect of enveloping and disinfection methods on artefact formation on enveloped PSP plate images.

Authors:  Umut Pamukcu; Hatice Tetik; Ilkay Peker; Ozge Karadag Atas; Zuhre Zafersoy Akarslan
Journal:  Oral Radiol       Date:  2022-01-22       Impact factor: 1.882