Tracking brachytherapy sources using emission imaging with one flat panel detector.

Haijun Song1, James Bowsher, Shiva Das, Fang-Fang Yin.   

Abstract

This work proposes to use the radiation from brachytherapy sources to track their dwell positions in three-dimensional (3D) space. The prototype device uses a single flat panel detector and a BB tray. The BBs are arranged in a defined pattern. The shadow of the BBs on the flat panel is analyzed to derive the 3D coordinates of the illumination source, i.e., the dwell position of the brachytherapy source. A kilovoltage x-ray source located 3.3 m away was used to align the center BB with the center pixel on the flat panel detector. For a test plan of 11 dwell positions, with an Ir-192 high dose rate unit, one projection was taken for each dwell point, and locations of the BB shadows were manually identified on the projection images. The 3D coordinates for the 11 dwell positions were reconstructed based on two BBs. The distances between dwell points were compared with the expected values. The average difference was 0.07 cm with a standard deviation of 0.15 cm. With automated BB shadow recognition in the future, this technique possesses the potential of tracking the 3D trajectory and the dwell times of a brachytherapy source in real time, enabling real time source position verification.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19472615     DOI: 10.1118/1.3081402

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Relative dosimetrical verification in high dose rate brachytherapy using two-dimensional detector array IMatriXX.

Authors:  A Manikandan; Sarkar Biplab; Perianayagam A David; R Holla; T R Vivek; N Sujatha
Journal:  J Med Phys       Date:  2011-07

2.  Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy.

Authors:  Katsunori Yogo; Akihiro Matsushita; Yuya Tatsuno; Takahiro Shimo; Seiko Hirota; Marika Nozawa; Shuichi Ozawa; Hiromichi Ishiyama; Hiroshi Yasuda; Yasushi Nagata; Kazushige Hayakawa
Journal:  Sci Rep       Date:  2020-02-27       Impact factor: 4.379

3.  Automated multi-parameter high-dose-rate brachytherapy quality assurance via radioluminescence imaging.

Authors:  Mengyu Jia; Tae Jin Kim; Yong Yang; Lei Xing; Paul De Jean; Elliot Grafil; Cesare H Jenkins; Benjamin P Fahimian
Journal:  Phys Med Biol       Date:  2020-11-17       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.