Literature DB >> 19465285

Tilt and decentration of spherical and aspheric intraocular lenses: effect on higher-order aberrations.

Martin Baumeister1, Jens Bühren, Thomas Kohnen.   

Abstract

PURPOSE: To determine the impact of spherical and aspheric foldable intraocular lens (IOL) tilt and decentration on optical quality after cataract surgery in an intraindividual comparative study.
SETTING: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.
METHODS: Randomized implantation of a spherical IOL (Sensar AR40e) was performed in 1 eye and of an aspheric IOL with negative spherical aberration (Tecnis Z9000) in the contralateral eye. Three to 4 months postoperatively, the wavefront was measured and higher-order aberrations (HOAs) were calculated for virtual pupil diameters of 3.5 mm and 6.0 mm. Tilt and decentration of the IOLs were measured using Scheimpflug photography. The tilt and decentration, HOAs, and best corrected visual Strehl ratio of the optical transfer function (BCVSOTF) calculated from the wavefront aberration were compared. The effect of tilt and decentration on HOAs and optical quality was assessed using multiple regression analysis.
RESULTS: The mean optic tilt was 2.89 degrees +/- 1.46 (SD) for the spherical IOL and 2.85 +/- 1.36 degrees for the aspheric IOL. The mean optic decentration was 0.19 +/- 0.12 mm and 0.27 +/- 0.16 mm, respectively. No significant intergroup differences in IOL tilt or decentration were found. Tilt and decentration did not significantly affect the BCVSOTF with either IOL.
CONCLUSIONS: The amounts of tilt and decentration of both IOLs were not large enough to cause deterioration of optical quality. Thus, when IOL tilt and decentration are within normal limits, they do not compromise the correction of spherical aberration by the aspheric IOL.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19465285     DOI: 10.1016/j.jcrs.2009.01.023

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  22 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  Early clinical outcome with a new monofocal microincision intraocular lens.

Authors:  Baha Toygar; Ozge Yabas Kiziloglu; Okan Toygar; Ali Murat Hacimustafaoglu
Journal:  Int Ophthalmol       Date:  2016-01-16       Impact factor: 2.031

3.  Internal spherical aberration by ray tracing-type aberrometry in multifocal pseudophakic eyes.

Authors:  I Jun; Y J Choi; E K Kim; K Y Seo; T-I Kim
Journal:  Eye (Lond)       Date:  2012-06-29       Impact factor: 3.775

4.  [Intraocular lenses for microincisional cataract surgery].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

5.  Pathologic assessment of complications with asymmetric or sulcus fixation of square-edged hydrophobic acrylic intraocular lenses.

Authors:  Kevin R Kirk; Liliana Werner; Ryan Jaber; Susan Strenk; Lawrence Strenk; Nick Mamalis
Journal:  Ophthalmology       Date:  2012-03-15       Impact factor: 12.079

Review 6.  The journey to femtosecond laser-assisted cataract surgery: new beginnings or a false dawn?

Authors:  S Trikha; A M J Turnbull; R J Morris; D F Anderson; P Hossain
Journal:  Eye (Lond)       Date:  2013-02-01       Impact factor: 3.775

7.  Optical coherence tomography-based deep learning algorithm for quantification of the location of the intraocular lens.

Authors:  Chen Xin; Gui-Bin Bian; Haojie Zhang; Weipeng Liu; Zhe Dong
Journal:  Ann Transl Med       Date:  2020-07

8.  Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery.

Authors:  Thomas Sauer; Ulrich Mester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-02       Impact factor: 3.117

9.  IOL tilt and decentration estimation from 3 dimensional reconstruction of OCT image.

Authors:  Xiaogang Wang; Jing Dong; Xiaoliang Wang; Qiang Wu
Journal:  PLoS One       Date:  2013-03-15       Impact factor: 3.240

10.  Research on calculation of the IOL tilt and decentration based on surface fitting.

Authors:  Lin Li; Ke Wang; Yan Yan; Xudong Song; Zhicheng Liu
Journal:  Comput Math Methods Med       Date:  2013-07-14       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.