Literature DB >> 10497290

Effects of metal ions on white blood cells of patients with failed total joint arthroplasties.

L Savarino1, D Granchi, G Ciapetti, S Stea, M E Donati, G Zinghi, G Fontanesi, R Rotini, L Montanaro.   

Abstract

In this study twenty-two patients who had revision surgery for aseptic loosening of joint prostheses were examined. The concentration in serum of soluble products of corrosion from the implant, that is, chromium (Cr), cobalt (Co), and nickel (Ni) ions, and the number of white blood cells (leucocytes, myeloid cells, lymphocyte subpopulations) were measured. Twenty patients with no implants were used as controls. The patients who had revision surgery showed normal Ni concentration whereas by statistical analysis that same patient group was shown to have serum Cr and Co levels significantly higher than those of the control. By flow cytometry, a significant decrease of leucocytes, myeloid cells, lymphocytes, and CD16 populations as found in patients versus controls whereas CD3, CD4, CD8, and CD20 positive cells were decreased, but not significantly. In the arthroplasty patients the Cr concentrations were inversely correlated with some of the immunologic parameters while no significant correlation was found between Co levels and decreased lymphocyte subpopulations. Only in revision surgery patients with high Cr concentrations did we find a significant decrease of lymphocytes, namely of CD4 and CD16 positive cells; revision surgery patients with normal Cr concentrations did not show a significant decrease of lymphocyte subpopulations. These data suggest that the presence of metal ions, especially chromium, released from prosthesis components could be associated with changes of lymphocyte subpopulations in patients with loosening of joint prostheses. Copyright 1999 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10497290     DOI: 10.1002/(sici)1097-4636(19991215)47:4<543::aid-jbm11>3.0.co;2-g

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  13 in total

1.  Differential gene expression in the periprosthetic membrane: lubricin as a new possible pathogenetic factor in prosthesis loosening.

Authors:  Lars Morawietz; Thorsten Gehrke; Lars Frommelt; Petra Gratze; Andreas Bosio; Johannes Möller; Bernhard Gerstmayer; Veit Krenn
Journal:  Virchows Arch       Date:  2003-05-29       Impact factor: 4.064

Review 2.  [Wear particles: key to aseptic prosthetic loosening?].

Authors:  M Otto; J Kriegsmann; T Gehrke; S Bertz
Journal:  Pathologe       Date:  2006-11       Impact factor: 1.011

3.  Improving cytocompatibility of Co28Cr6Mo by TiO2 coating: gene expression study in human endothelial cells.

Authors:  R Tsaryk; K Peters; R E Unger; M Feldmann; B Hoffmann; F Heidenau; C J Kirkpatrick
Journal:  J R Soc Interface       Date:  2013-07-03       Impact factor: 4.118

4.  Ellagic Acid from Terminalia arjuna Fruits Protects Against Chromium and Cobalt Toxicity in Primary Human Lymphocytes.

Authors:  Vijaya Lakshmi Bodiga; Praveen Kumar Vemuri; Madhukar Rao Kudle; Sreedhar Bodiga
Journal:  Biol Trace Elem Res       Date:  2021-08-25       Impact factor: 3.738

5.  The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Authors:  Donald S Garbuz; Michael Tanzer; Nelson V Greidanus; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2009-08-21       Impact factor: 4.176

6.  Effects of phosphate-based glasses on T lymphocytes in vitro.

Authors:  A Kesisoglou; J C Knowles; I Olsen
Journal:  J Mater Sci Mater Med       Date:  2002-12       Impact factor: 3.896

7.  Does ion release differ between hip resurfacing and metal-on-metal THA?

Authors:  Antonio Moroni; Lucia Savarino; Matteo Cadossi; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2008-01-09       Impact factor: 4.176

Review 8.  Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

Authors:  Divya Rani Bijukumar; Abhijith Segu; Júlio C M Souza; XueJun Li; Mark Barba; Louis G Mercuri; Joshua J Jacobs; Mathew Thoppil Mathew
Journal:  Nanomedicine       Date:  2018-01-12       Impact factor: 5.307

9.  Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation.

Authors:  Christopher Brown; Sophie Williams; Joanne L Tipper; John Fisher; Eileen Ingham
Journal:  J Mater Sci Mater Med       Date:  2006-12-14       Impact factor: 4.727

10.  Metal ion levels and lymphocyte counts: ASR hip resurfacing prosthesis vs. standard THA: 2-year results from a randomized study.

Authors:  Jeannette Ø Penny; Jens-Erik Varmarken; Ole Ovesen; Christian Nielsen; Søren Overgaard
Journal:  Acta Orthop       Date:  2013-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.