Literature DB >> 19443039

Culturing thick brain slices: an interstitial 3D microperfusion system for enhanced viability.

Komal Rambani1, Jelena Vukasinovic, Ari Glezer, Steve M Potter.   

Abstract

Brain slice preparations are well-established models for a wide spectrum of in vitro investigations in the neuroscience discipline. However, these investigations are limited to acute preparations or thin organotypic culture preparations due to the lack of a successful method that allows culturing of thick organotypic brain slices. Thick brain slice cultures suffer necrosis due to ischemia deep in the tissue resulting from a destroyed circulatory system and subsequent diffusion-limited supply of nutrients and oxygen. Although thin organotypic brain slice cultures can be successfully cultured using a well-established roller-tube method (a monolayer organotypic culture) (Gahwiler B H. Organotypic monolayer cultures of nervous tissue. J Neurosci Methods. 1981; 4: 329-342) or a membrane-insert method (up to 1-4 cell layers, <150 microm) (Stoppini L, Buchs PA, Muller D. A simple method for organotypic cultures of neural tissue. J Neurosci Methods 1991; 37: 173-182), these methods fail to support thick tissue preparations. A few perfusion methods (using submerged or interface/microfluidic chambers) have been reported to enhance the longevity (up to few hours) of acute slice preparations (up to 600 microm thick) (Hass HL, Schaerer B, Vosmansky M. A simple perfusion chamber for study of nervous tissue slices in vitro. J Neurosci Methods 1979; 1: 323-325; Nicoll RA, Alger BE. A simple chamber for recording from submerged brain slices. J Neurosci Methods 1981; 4: 153-156; Passeraub PA, Almeida AC, Thakor NV. Design, microfabrication and characterization of a microfluidic chamber for the perfusion of brain tissue slices. J Biomed Dev 2003; 5: 147-155). Here, we report a unique interstitial microfluidic perfusion technique to culture thick (700 microm) organotypic brain slices. The design of the custom-made microperfusion chamber facilitates laminar, interstitial perfusion of oxygenated nutrient medium throughout the tissue thickness with concomitant removal of depleted medium and catabolites. We examined the utility of this perfusion method to enhance the viability of the thick organotypic brain slice cultures after 2 days and 5 days in vitro (DIV). We investigated the range of amenable flow rates that enhance the viability of 700 microm thick organotypic brain slices compared to the unperfused control cultures. Our perfusion method allows up to 84.6% viability (p<0.01) and up to 700 microm thickness, even after 5 DIV. Our results also confirm that these cultures are functionally active and have their in vivo cyto-architecture preserved. Prolonged viability of thick organotypic brain slice cultures will benefit scientists investigating network properties of intact organotypic neuronal networks in a reliable and repeatable manner.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19443039      PMCID: PMC2742628          DOI: 10.1016/j.jneumeth.2009.03.016

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  46 in total

1.  Integrins are involved in synaptogenesis, cell spreading, and adhesion in the postnatal brain.

Authors:  Irina Nikonenko; Nicolas Toni; Marlis Moosmayer; Yasushi Shigeri; Dominique Muller; Leslie Sargent Jones
Journal:  Brain Res Dev Brain Res       Date:  2003-02-16

2.  Assessment of factors regulating axon growth between the cortex and spinal cord in organotypic co-cultures: effects of age and neurotrophic factors.

Authors:  Yosuke Oishi; Janie Baratta; Richard T Robertson; Oswald Steward
Journal:  J Neurotrauma       Date:  2004-03       Impact factor: 5.269

3.  A simple perfusion chamber for the study of nervous tissue slices in vitro.

Authors:  H L Haas; B Schaerer; M Vosmansky
Journal:  J Neurosci Methods       Date:  1979-12       Impact factor: 2.390

4.  Organotypic monolayer cultures of nervous tissue.

Authors:  B H Gähwiler
Journal:  J Neurosci Methods       Date:  1981-12       Impact factor: 2.390

5.  A simple chamber for recording from submerged brain slices.

Authors:  R A Nicoll; B E Alger
Journal:  J Neurosci Methods       Date:  1981-08       Impact factor: 2.390

6.  Transient voltage and calcium-dependent outward currents in hippocampal CA3 pyramidal neurons.

Authors:  K L Zbicz; F F Weight
Journal:  J Neurophysiol       Date:  1985-04       Impact factor: 2.714

7.  Input- and subunit-specific AMPA receptor trafficking underlying long-term potentiation at hippocampal CA3 synapses.

Authors:  Wataru Kakegawa; Keisuke Tsuzuki; Yukari Yoshida; Kimihiko Kameyama; Seiji Ozawa
Journal:  Eur J Neurosci       Date:  2004-07       Impact factor: 3.386

8.  Long-lasting potentiation of synaptic transmission in the dentate area of the anaesthetized rabbit following stimulation of the perforant path.

Authors:  T V Bliss; T Lomo
Journal:  J Physiol       Date:  1973-07       Impact factor: 5.182

9.  Neurogenesis in hippocampal slice cultures.

Authors:  Olivier Raineteau; Lotty Rietschin; Gérard Gradwohl; François Guillemot; Beat H Gähwiler
Journal:  Mol Cell Neurosci       Date:  2004-06       Impact factor: 4.314

10.  Mifepristone (RU486) protects Purkinje cells from cell death in organotypic slice cultures of postnatal rat and mouse cerebellum.

Authors:  A M Ghoumari; I Dusart; M El-Etr; F Tronche; C Sotelo; M Schumacher; E-E Baulieu
Journal:  Proc Natl Acad Sci U S A       Date:  2003-06-16       Impact factor: 11.205

View more
  35 in total

Review 1.  Brain organoids: advances, applications and challenges.

Authors:  Xuyu Qian; Hongjun Song; Guo-Li Ming
Journal:  Development       Date:  2019-04-16       Impact factor: 6.868

2.  Two-way communication between ex vivo tissues on a microfluidic chip: application to tumor-lymph node interaction.

Authors:  Sangjo Shim; Maura C Belanger; Alexandra R Harris; Jennifer M Munson; Rebecca R Pompano
Journal:  Lab Chip       Date:  2019-03-13       Impact factor: 6.799

3.  A dense poly(ethylene glycol) coating improves penetration of large polymeric nanoparticles within brain tissue.

Authors:  Elizabeth A Nance; Graeme F Woodworth; Kurt A Sailor; Ting-Yu Shih; Qingguo Xu; Ganesh Swaminathan; Dennis Xiang; Charles Eberhart; Justin Hanes
Journal:  Sci Transl Med       Date:  2012-08-29       Impact factor: 17.956

4.  A microfluidic brain slice perfusion chamber for multisite recording using penetrating electrodes.

Authors:  Alexander J Blake; Frank C Rodgers; Anna Bassuener; Joseph A Hippensteel; Thomas M Pearce; Timothy R Pearce; Ewa D Zarnowska; Robert A Pearce; Justin C Williams
Journal:  J Neurosci Methods       Date:  2010-02-26       Impact factor: 2.390

5.  Recording Synaptic Plasticity in Acute Hippocampal Slices Maintained in a Small-volume Recycling-, Perfusion-, and Submersion-type Chamber System.

Authors:  Weiguang Weng; Dongxue Li; Cheng Peng; Thomas Behnisch
Journal:  J Vis Exp       Date:  2018-01-01       Impact factor: 1.355

6.  Fitting tissue chips and microphysiological systems into the grand scheme of medicine, biology, pharmacology, and toxicology.

Authors:  David E Watson; Rosemarie Hunziker; John P Wikswo
Journal:  Exp Biol Med (Maywood)       Date:  2017-10

7.  Perfused drop microfluidic device for brain slice culture-based drug discovery.

Authors:  Jing Liu; Liping Pan; Xuanhong Cheng; Yevgeny Berdichevsky
Journal:  Biomed Microdevices       Date:  2016-06       Impact factor: 2.838

8.  A multifunctional pipette for localized drug administration to brain slices.

Authors:  Aikeremu Ahemaiti; Alar Ainla; Gavin D M Jeffries; Holger Wigström; Owe Orwar; Aldo Jesorka; Kent Jardemark
Journal:  J Neurosci Methods       Date:  2013-08-19       Impact factor: 2.390

Review 9.  Methods to measure, model and manipulate fluid flow in brain.

Authors:  Krishnashis Chatterjee; Cora M Carman-Esparza; Jennifer M Munson
Journal:  J Neurosci Methods       Date:  2019-12-12       Impact factor: 2.390

Review 10.  Microfluidic platforms for mechanobiology.

Authors:  William J Polacheck; Ran Li; Sebastien G M Uzel; Roger D Kamm
Journal:  Lab Chip       Date:  2013-05-07       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.