Literature DB >> 19438966

Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values.

Michael M Bornstein1, Christopher N Hart, Sandro A Halbritter, Dean Morton, Daniel Buser.   

Abstract

PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing.
MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements.
RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%.
CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19438966     DOI: 10.1111/j.1708-8208.2009.00148.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  31 in total

1.  Dendritic cell responses to surface properties of clinical titanium surfaces.

Authors:  Peng Meng Kou; Zvi Schwartz; Barbara D Boyan; Julia E Babensee
Journal:  Acta Biomater       Date:  2010-10-25       Impact factor: 8.947

Review 2.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

3.  Assessment of implant stability following sinus lift procedures with different grafting materials.

Authors:  Damir Jelušić; Ivan Puhar; Darije Plančak
Journal:  Acta Stomatol Croat       Date:  2014-03

4.  Coordinated regulation of mesenchymal stem cell differentiation on microstructured titanium surfaces by endogenous bone morphogenetic proteins.

Authors:  Rene Olivares-Navarrete; Sharon L Hyzy; David A Haithcock; Caitlin A Cundiff; Zvi Schwartz; Barbara D Boyan
Journal:  Bone       Date:  2014-12-30       Impact factor: 4.398

5.  In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants.

Authors:  Luiz-Antônio-Borelli Barros; Caio-Fossalussa da Silva; Germana-de Villa Camargos; Elcio Marcantonio; Guilherme-José-Pimentel-Lopes de Oliveira; Luiz-Antônio-Borelli Barros-Filho
Journal:  J Clin Exp Dent       Date:  2022-02-01

6.  Direct and indirect effects of microstructured titanium substrates on the induction of mesenchymal stem cell differentiation towards the osteoblast lineage.

Authors:  Rene Olivares-Navarrete; Sharon L Hyzy; Daphne L Hutton; Christopher P Erdman; Marco Wieland; Barbara D Boyan; Zvi Schwartz
Journal:  Biomaterials       Date:  2010-01-06       Impact factor: 12.479

7.  Effect of decreased implant healing time on bone (re)modeling adjacent to plateaued implants under functional loading in a dog model.

Authors:  Jing Dai; Ning Cheng; Richard J Miron; Bin Shi; Xiangrong Cheng; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2013-02-03       Impact factor: 3.573

8.  Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study.

Authors:  Ramón Silva; Pablo Villalón; Felipe Cáceres
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-29

9.  The effect of fibronectin-coated implant on canine osseointegration.

Authors:  Sungtae Kim; Woo-Chun Myung; Jung-Seok Lee; Jae-Kook Cha; Ui-Won Jung; Hyeong-Cheol Yang; In-Seop Lee; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

10.  Current knowledge about the hydrophilic and nanostructured SLActive surface.

Authors:  Ann Wennerberg; Silvia Galli; Tomas Albrektsson
Journal:  Clin Cosmet Investig Dent       Date:  2011-09-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.